Research on Transient Overvoltage Control Strategy of UHVDC with Photovoltaic Power Plant

Author(s):  
Yichao Jia ◽  
Linan Qu ◽  
Ning Chen ◽  
Hongying Zhang ◽  
Shuanbao Niu ◽  
...  
2020 ◽  
Vol 2020 ◽  
pp. 1-13
Author(s):  
Shuanbao Niu ◽  
Xianbo Ke ◽  
Qiang Shen ◽  
Chao Huo ◽  
Ning Chen ◽  
...  

The development of smart power systems in Industry 4.0 will bring people better quality electrical energy. The photovoltaic power generation system in the smart grid for Industry 4.0 is also the focus of development. The rapid development of photovoltaic power generation systems will bring people cleaner and greener energy. However, it will cause the transient overvoltage phenomenon near the DC sending terminal when the large-scale photovoltaic plant is connected to the power grid, further bringing about a profound impact on the power grid and its security and stability. In this paper, it is proposed that the rise of transient overvoltage at the photovoltaic terminal is caused by three main factors including the reactive power surplus of DC commutation failure, the weak power grid at the sending terminal, and the control characteristics of the photovoltaic plant. Then, the coordinated control strategy of transient overvoltage is proposed, and the overvoltage control strategy of the DC transmission terminal and the photovoltaic power plant control strategy are, respectively, optimized. Finally, the influence parameters of overvoltage are analysed and the corresponding photovoltaic strategy is presented. The optimization results of photovoltaic parameters and the proposed strategies of photovoltaic power generation can effectively restrain the voltage or frequency fluctuation and power oscillation caused by HVDC commutation failure. This study promotes the development of the photovoltaic power generation system in the intelligent power system of industry 4.0.


Author(s):  
Anu Priya. K.R ◽  
Sasilatha T

<p>This paper presents investigation of conceivable transient overvoltage that can be produced amid vacuum electrical switch (VCB) operation at the association purpose of a photovoltaic power plant. Average exchanging occasion that is identified with VCB concerns stimulation and de-empowerment of emptied transformer. Nonetheless, at the common photovoltaic power plant the transformer is sustained by an inverter outfitted with LC (or LCL) channels that are important for constraint of music and swell in voltage and current. From the perspective of exchanging operations, the inductance and capacitance of the LV side associated channel influence the regular recurrence of the transformer, which is reflected by various transient framework reaction amid VCB working. In this article, research facility estimation of overvoltage produced amid dispersion transformer exchanging by methods for VCB is examined. Effect of the LC channel associated at the LV side on the overvoltage concealment was contemplated. EMTP-ATP recreations were directed with a specific end goal to confirm the likelihood of homeless people end by methods for extra arrangement associated RL gag at the transformer medium voltage side.</p>


2012 ◽  
Vol 608-609 ◽  
pp. 1120-1126 ◽  
Author(s):  
De Shun Wang ◽  
Bo Yang ◽  
Lian Tao Ji

A static frequency converter start-up control strategy for pumped-storage power unit is presented. And rotor position detecting without position sensor is realized according to voltage and magnetism equations of ideal synchronous motor mathematics model. The mechanism and implementation method of initial rotor position determination and rotor position estimation under low frequency without position sensor are expounded and validated by simulations. Based on the mentioned control strategy, first set of a static frequency converter start-up device in China for large-scale pumped-storage unit is developed, which is applied to start-up control test in the 90 MW generator/motor of Panjiakou Pumped-storage Power Plant. Test results show that rotor position detecting, pulse commutation, natural commutation, and unit synchronous procedure control of static start-up are all proved. The outcomes have been applied in running equipment, which proves the feasibility of mentioned method.


Sign in / Sign up

Export Citation Format

Share Document