End-Use Electricity Demand Profile Analysis Using MESSAGE Modeling Approach

Author(s):  
A. A. Mati ◽  
A. S. Ajuji ◽  
B. G. Bajoga
1983 ◽  
Vol 6 (3) ◽  
pp. 177-183 ◽  
Author(s):  
T.N. Goh ◽  
S.S. Choi ◽  
S.B. Chen
Keyword(s):  

Author(s):  
Ramses Vega ◽  
Hector E. Campbell ◽  
Juan de Dios Ocampo ◽  
Diego R. Bonilla G.

This paper shows the simulation and design of a flat plate solar collector system, used to feed hot water to a typical home located in the city of Mexicali, Baja California, México. The system consists of a solar collector, a storage tank, a water pump and accessories and special tools that allow its proper operation. Analyzing the consumption and end use of water in a typical House, a demand profile is established, which combined with the weather information of the region, constitutes the input parameters required for the simulation of the system, which is performed with the software package TRNSYS. Mexicali, due to its location (latitude 32 °, longitude 114 °) and semi-desert condition presents high temperatures in the summer and low in winter, so the design and operation of such systems require special features, not always considered in the conventional ratings. This paper presents methods for simulation and design oriented to optimize the dimensioning and operation of this type of solar heaters in regions with extreme temperature conditions.


Author(s):  
Tumiran Tumiran ◽  
Sarjiya Sarjiya ◽  
Lesnanto Multa Putranto ◽  
Edwin Nugraha Putra ◽  
Rizki Firmansyah Setya Budi ◽  
...  

Author(s):  
Dongsu Kim ◽  
Heejin Cho ◽  
Rogelio Luck

This study evaluates potential aggregate effects of net-zero energy building (NZEB) implementations on the electrical grid in simulation-based analysis. Many studies have been conducted on how effective NZEB designs can be achieved, however the potential impact of NZEBs have not been explored sufficiently. As significant penetration of NZEBs occurs, the aggregated electricity demand profile of the buildings on the electrical grid would experience dramatic changes. To estimate the impact of NZEBs on the electrical grid, a simulation-based study of an office building with a grid-tied PV power generation system is conducted. This study assumes that net-metering is available for NZEBs such that the excess on-site PV generation can be fed to the electrical grid. The impact of electrical energy storage (EES) within NZEBs on the electrical grid is also considered in this study. Finally, construction weighting factors of the office building type in U.S. climate zones are used to estimate the number of national office buildings. In order to consider the adoption of NZEBs in the future, this study examines scenarios with 20%, 50%, and 100% of the U.S. office building stock are composed of NZEBs. Results show that annual electricity consumption of simulated office buildings in U.S. climate locations includes the range of around 85 kWh/m2-year to 118 kWh/m2-year. Each simulated office building employs around 242 kWp to 387 kWp of maximum power outputs in the installation of on-site PV power systems to enable NZEB balances. On a national scale, the daily on-site PV power generation within NZEBs can cover around 50% to 110% of total daily electricity used in office buildings depending on weather conditions. The peak difference of U.S. electricity demand typically occurs when solar radiation is at its highest. The peak differences from the actual U.S. electricity demand on the representative summer day show 9.8%, 4.9%, and 2.0% at 12 p.m. for 100%, 50%, and 20% of the U.S. NZEB stocks, respectively. Using EES within NZEBs, the peak differences are reduced and shifted from noon to the beginning of the day, including 7.7%, 3.9%, and 1.5% for each percentage U.S. NZEB stock. NZEBs tend to create the significant curtailment of the U.S. electricity demand profile, typically during the middle of the winter day. The percentage differences at a peak point (12 p.m.) are 8.3%, 4.2%, and 1.7% for 100%, 50%, and 20% of the U.S. NZEB stocks, respectively. However, using EES on the representative winter day can flatten curtailed electricity demand curves by shifting the peak difference point to the beginning and the late afternoon of the day. The shifted peak differences show 7.4%, 3.7%, and 1.5% at 9 a.m. for three U.S. NZEB stock scenarios, respectively.


Energies ◽  
2020 ◽  
Vol 13 (9) ◽  
pp. 2357
Author(s):  
Rick Cox ◽  
Shalika Walker ◽  
Joep van der Velden ◽  
Phuong Nguyen ◽  
Wim Zeiler

The built environment has the potential to contribute to maintaining a reliable grid at the demand side by offering flexibility services to a future Smart Grid. In this study, an office building is used to demonstrate forecast-driven building energy flexibility by operating a Battery Electric Storage System (BESS). The objective of this study is, therefore, to stabilize/flatten a building energy demand profile with the operation of a BESS. First, electricity demand forecasting models are developed and assessed for each individual load group of the building based on their characteristics. For each load group, the prediction models show Coefficient of Variation of the Root Mean Square Error (CVRMSE) values below 30%, which indicates that the prediction models are suitable for use in engineering applications. An operational strategy is developed aiming at meeting the flattened electricity load shape objective. Both the simulation and experimental results show that the flattened load shape objective can be met more than 95% of the time for the evaluation period without compromising the thermal comfort of users. Accurate energy demand forecasting is shown to be pivotal for meeting load shape objectives.


2015 ◽  
Vol 72 ◽  
pp. 285-292 ◽  
Author(s):  
Ilze Laicane ◽  
Dagnija Blumberga ◽  
Andra Blumberga ◽  
Marika Rosa

2014 ◽  
Vol 62 ◽  
pp. 91-100 ◽  
Author(s):  
Seungho Lee ◽  
David Whaley ◽  
Wasim Saman

Sign in / Sign up

Export Citation Format

Share Document