Exploiting test technology in the field test environment

Author(s):  
Ben Lyon ◽  
Terry Coles ◽  
Doug MacLennan
2014 ◽  
Vol 568-570 ◽  
pp. 478-482
Author(s):  
Hua Yun Yang

EVT (electronic voltage transformer) is one of the key devices of the intelligent substation. This paper introduces the basic principles of EVT error tests. By analyzing the test environment of EVT with GIS structure, this paper establishes the high-voltage side equivalent circuit for the field EVT calibration methods and proposes to carry out field boost for the EVT with GIS structure, which could effectively improve the field calibration efficiency of EVT. Based on the research on the complex field environment of EVT, this paper puts forward the field test methods of EVT with AIS structure and the results show the effectiveness and correctness of this study.


1995 ◽  
Vol 31 (6) ◽  
pp. 1381-1389 ◽  
Author(s):  
M.O. Durham ◽  
D.H. Neuroth ◽  
K. Ashenayi ◽  
T. Wallace
Keyword(s):  

Author(s):  
Wang Zheng-fang ◽  
Z.F. Wang

The main purpose of this study highlights on the evaluation of chloride SCC resistance of the material,duplex stainless steel,OOCr18Ni5Mo3Si2 (18-5Mo) and its welded coarse grained zone(CGZ).18-5Mo is a dual phases (A+F) stainless steel with yield strength:512N/mm2 .The proportion of secondary Phase(A phase) accounts for 30-35% of the total with fine grained and homogeneously distributed A and F phases(Fig.1).After being welded by a specific welding thermal cycle to the material,i.e. Tmax=1350°C and t8/5=20s,microstructure may change from fine grained morphology to coarse grained morphology and from homogeneously distributed of A phase to a concentration of A phase(Fig.2).Meanwhile,the proportion of A phase reduced from 35% to 5-10°o.For this reason it is known as welded coarse grained zone(CGZ).In association with difference of microstructure between base metal and welded CGZ,so chloride SCC resistance also differ from each other.Test procedures:Constant load tensile test(CLTT) were performed for recording Esce-t curve by which corrosion cracking growth can be described, tf,fractured time,can also be recorded by the test which is taken as a electrochemical behavior and mechanical property for SCC resistance evaluation. Test environment:143°C boiling 42%MgCl2 solution is used.Besides, micro analysis were conducted with light microscopy(LM),SEM,TEM,and Auger energy spectrum(AES) so as to reveal the correlation between the data generated by the CLTT results and micro analysis.


Sign in / Sign up

Export Citation Format

Share Document