Electrical trees in solids and streamers in liquids - structural analogies and differences

Author(s):  
M. Sack ◽  
Y. Julliard ◽  
R. Badent ◽  
A.J. Schwab
Keyword(s):  
Sensors ◽  
2021 ◽  
Vol 21 (7) ◽  
pp. 2562
Author(s):  
Abdullahi Abubakar Mas’ud ◽  
Arunachalam Sundaram ◽  
Jorge Alfredo Ardila-Rey ◽  
Roger Schurch ◽  
Firdaus Muhammad-Sukki ◽  
...  

In high-voltage (HV) insulation, electrical trees are an important degradation phenomenon strongly linked to partial discharge (PD) activity. Their initiation and development have attracted the attention of the research community and better understanding and characterization of the phenomenon are needed. They are very damaging and develop through the insulation material forming a discharge conduction path. Therefore, it is important to adequately measure and characterize tree growth before it can lead to complete failure of the system. In this paper, the Gaussian mixture model (GMM) has been applied to cluster and classify the different growth stages of electrical trees in epoxy resin insulation. First, tree growth experiments were conducted, and PD data captured from the initial to breakdown stage of the tree growth in epoxy resin insulation. Second, the GMM was applied to categorize the different electrical tree stages into clusters. The results show that PD dynamics vary with different stress voltages and tree growth stages. The electrical tree patterns with shorter breakdown times had identical clusters throughout the degradation stages. The breakdown time can be a key factor in determining the degradation levels of PD patterns emanating from trees in epoxy resin. This is important in order to determine the severity of electrical treeing degradation, and, therefore, to perform efficient asset management. The novelty of the work presented in this paper is that for the first time the GMM has been applied for electrical tree growth classification and the optimal values for the hyperparameters, i.e., the number of clusters and the appropriate covariance structure, have been determined for the different electrical tree clusters.


2019 ◽  
Vol 2019 ◽  
pp. 1-10 ◽  
Author(s):  
Chaofei Gao ◽  
Yanlong Yu ◽  
Zan Wang ◽  
Wei Wang ◽  
Liwei Zheng ◽  
...  

Based on the slice materials of 35 kV and 110 kV XLPE cables, an experimental platform is built to study the relationship between electrical tree and PDs in XLPE with different voltage levels. There are three significant statistical characteristics of the PDs during the growth of electrical trees. The analysis of the results shows that each growth stage has certain characteristics. Different features existed between the growth of the electrical trees and the PD in the insulation of the 35 and 110 kV cables. Evident characteristics such as large spans of time and frequency were present as the electrical trees grew violently in the equivalent time-frequency diagram at every stage. These results could provide criteria for the identification of the deterioration using PD to monitor cables in service at rated voltages. The results are important for the identification of defects in cable insulation in order to provide an early warning of insulation breakdown in the cables.


2014 ◽  
Vol 21 (1) ◽  
pp. 53-63 ◽  
Author(s):  
Roger Schurch ◽  
Simon Rowland ◽  
Robert Bradley ◽  
Philip Withers

2021 ◽  
Vol 28 (6) ◽  
pp. 1988-1995
Author(s):  
Haoyue Wang ◽  
Wei Wang ◽  
Feng Wu ◽  
Xiaowei Wang ◽  
Qilong Xu ◽  
...  

2018 ◽  
Vol 25 (6) ◽  
pp. 2250-2258 ◽  
Author(s):  
Zepeng Lv ◽  
Simon M Rowland ◽  
Siyuan Chen ◽  
Hualong Zheng