A 16×20 electrochemical CMOS biosensor array with in-pixel averaging using polar modulation

Author(s):  
Chung-Lun Hsu ◽  
Alexander Sun ◽  
Yunting Zhao ◽  
Eliah Aronoff-Spencer ◽  
Drew A. Hall
2002 ◽  
Vol 7 (2) ◽  
pp. 3-14 ◽  
Author(s):  
R. Baronas ◽  
J. Christensen ◽  
F. Ivanauskas ◽  
J. Kulys

A mathematical model of amperometric biosensors has been developed. The model bases on non-stationary diffusion equations containing a non-linear term related to Michaelis-Menten kinetic of the enzymatic reaction. The model describes the biosensor response to mixtures of multiple compounds in two regimes of analysis: batch and flow injection. Using computer simulation, large amount of biosensor response data were synthesised for calibration of a biosensor array to be used for characterization of wastewater. The computer simulation was carried out using the finite difference technique.


Nanomaterials ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 545
Author(s):  
Yi Zhang ◽  
Wei Jiang ◽  
Dezhi Feng ◽  
Chenguang Wang ◽  
Yi Xu ◽  
...  

2D molybdenum disulfide (MoS2)-based thin film transistors are widely used in biosensing, and many efforts have been made to improve the detection limit and linear range. However, in addition to the complexity of device technology and biological modification, the compatibility of the physical device with biological solutions and device reusability have rarely been considered. Herein, we designed and synthesized an array of MoS2 by employing a simple-patterned chemical vapor deposition growth method and meanwhile exploited a one-step biomodification in a sensing pad based on DNA tetrahedron probes to form a bio-separated sensing part. This solves the signal interference, solution erosion, and instability of semiconductor-based biosensors after contacting biological solutions, and also allows physical devices to be reused. Furthermore, the gate-free detection structure that we first proposed for DNA (BRCA1) detection demonstrates ultrasensitive detection over a broad range of 1 fM to 1 μM with a good linear response of R2 = 0.98. Our findings provide a practical solution for high-performance, low-cost, biocompatible, reusable, and bio-separated biosensor platforms.


ACS Nano ◽  
2017 ◽  
Vol 11 (9) ◽  
pp. 8864-8870 ◽  
Author(s):  
Giovanni Rizzi ◽  
Jung-Rok Lee ◽  
Christina Dahl ◽  
Per Guldberg ◽  
Martin Dufva ◽  
...  

Author(s):  
Xiaowen Liu ◽  
Lin Li ◽  
Andrew J. Mason

Impedance spectroscopy is a powerful tool for characterizing materials that exhibit a frequency dependent behaviour to an applied electric field. This paper introduces a fully integrated multi-channel impedance extraction circuit that can both generate AC stimulus signals over a broad frequency range and also measure and digitize the real and imaginary components of the impedance response. The circuit was fabricated in a 0.5 μm complementary metal-oxide semiconductor. Tailored for cellular membrane interface characterization, the signal generator produces sinusoidal waves from 10 mHz to 10 kHz. To suit a variety of applications, the impedance extraction circuit provides a programmable current measurement range from 100 pA to 100 nA with a measured resolution of approximately 100 fA. Occupying only 0.045 mm 2 per measurement channel, the circuit is compact enough to include nearly 200 channels in a 3×3 mm 2 die area.


2003 ◽  
Author(s):  
Cordelia A. Zimmerer ◽  
Hans-Georg Braun ◽  
Marco Kitsche ◽  
Gerald Steiner ◽  
Steffen Friedrich ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document