A review of single-phase-to-ground fault location methods in distribution networks

Author(s):  
Yuan Li ◽  
Houlei Gao ◽  
Qiang Du ◽  
Xiaosheng Qi ◽  
Qingle Pang ◽  
...  
Energies ◽  
2020 ◽  
Vol 13 (15) ◽  
pp. 3917 ◽  
Author(s):  
Yangang Shi ◽  
Tao Zheng ◽  
Chang Yang

Traveling wave (TW)-based fault-location methods have been used to determine single-phase-to-ground fault distance in power-distribution networks. The previous approaches detected the arrival time of the initial traveling wave via single ended or multi-terminal measurements. Regarding the multi-branch effect, this paper utilized the reflected waves to obtain multiple arriving times through single ended measurement. Potential fault sections were estimated by searching for the possible traveling wave propagation paths in accordance with the structure of the distribution network. This approach used the entire propagation of a traveling wave measured at a single end without any prerequisite of synchronization, which is a must in multi-terminal measurements. The uniqueness of the fault section was guaranteed by several independent single-ended measurements. Traveling waves obtained in a real 10 kV distribution network were used to determine the fault section, and the results demonstrate the significant effectiveness of the proposed method.


Author(s):  
Jevgēnijs Linčiks ◽  
Dzintars Baranovskis

Single Phase Earth Fault Location in the Medium Voltage Distribution NetworksThis paper gives a description of the single phase earth fault location methods in the medium voltage networks. The single phase earth fault location in the medium voltage distribution networks is problematic now. The technical devices which are using in Latvia now do not allow to detect the single phase earth faults fast and high accuracy. Fast earth fault location should be possible by using the equipments which are calculating distance to earth faults. But precisely calculate the distance to the single phase earth faults in the medium voltage networks is very difficult. The paper presents the single earth fault location methods including the calculation methods for fault distance.


2014 ◽  
Vol 530-531 ◽  
pp. 353-356
Author(s):  
Run Sheng Li

Due to the high ground fault resistance and the complexity of power distribution network structure (such as too many nodes, branches and too long lines), adopting common traveling wave method and ac injection method can not effectively locate the single-phase grounding fault in the distribution network system.To solve above problems and determine the position of the point of failure prisely, this paper adopted the dc location method of injecting the dc signal from the point of failure under the power outage offline. This paper introduces the single phase dc method and the method of three phase dc, and the simulation shows that the dc location method is effective and feasible.