scholarly journals Reflected Traveling Wave Based Single-Ended Fault Location in Distribution Networks

Energies ◽  
2020 ◽  
Vol 13 (15) ◽  
pp. 3917 ◽  
Author(s):  
Yangang Shi ◽  
Tao Zheng ◽  
Chang Yang

Traveling wave (TW)-based fault-location methods have been used to determine single-phase-to-ground fault distance in power-distribution networks. The previous approaches detected the arrival time of the initial traveling wave via single ended or multi-terminal measurements. Regarding the multi-branch effect, this paper utilized the reflected waves to obtain multiple arriving times through single ended measurement. Potential fault sections were estimated by searching for the possible traveling wave propagation paths in accordance with the structure of the distribution network. This approach used the entire propagation of a traveling wave measured at a single end without any prerequisite of synchronization, which is a must in multi-terminal measurements. The uniqueness of the fault section was guaranteed by several independent single-ended measurements. Traveling waves obtained in a real 10 kV distribution network were used to determine the fault section, and the results demonstrate the significant effectiveness of the proposed method.

2014 ◽  
Vol 530-531 ◽  
pp. 353-356
Author(s):  
Run Sheng Li

Due to the high ground fault resistance and the complexity of power distribution network structure (such as too many nodes, branches and too long lines), adopting common traveling wave method and ac injection method can not effectively locate the single-phase grounding fault in the distribution network system.To solve above problems and determine the position of the point of failure prisely, this paper adopted the dc location method of injecting the dc signal from the point of failure under the power outage offline. This paper introduces the single phase dc method and the method of three phase dc, and the simulation shows that the dc location method is effective and feasible.


2011 ◽  
Vol 383-390 ◽  
pp. 2479-2483
Author(s):  
Qiao Lin Ding ◽  
Zhen Dong Yang ◽  
Ru Jun Xu

The 10kV distribution networks have complicated geographical environment and the lines with many branches, as well as high grounding resistance at fault point, thus result the difficult of locating fault. Traveling wave fault-location methods locate fault by the time of traveling wave from fault point to receiver or wave subtraction from fault point to two sides receivers, and the advantages of the methods are fast and have high precision. This paper introduced A, B, C, E four types traveling wave fault-location methods and their characteristics. Many simulations are taken for single-phase earth fault in a 10kV power distribution line with branches. By comparing the waves reflected from normal line and the fault one, the fault distance is determined by the first distortion point. As a result, the simulations indicate that the fault-location precision meet the actual requirement, Type C traveling wave fault-location method is feasible for the fault location in distribution networks.


2018 ◽  
Vol 20 (4) ◽  
pp. 417-429 ◽  
Author(s):  
Satyabrata Dash ◽  
Sukanta Dey ◽  
Deepak Joshi ◽  
Gaurav Trivedi

Purpose The purpose of this paper is to demonstrate the application of river formation dynamics to size the widths of power distribution network for very large-scale integration designs so that the wire area required by power rails is minimized. The area minimization problem is transformed into a single objective optimization problem subject to various design constraints, such as IR drop and electromigration constraints. Design/methodology/approach The minimization process is carried out using river formation dynamics heuristic. The random probabilistic search strategy of river formation dynamics heuristic is used to advance through stringent design requirements to minimize the wire area of an over-designed power distribution network. Findings A number of experiments are performed on several power distribution benchmarks to demonstrate the effectiveness of river formation dynamics heuristic. It is observed that the river formation dynamics heuristic outperforms other standard optimization techniques in most cases, and a power distribution network having 16 million nodes is successfully designed for optimal wire area using river formation dynamics. Originality/value Although many research works are presented in the literature to minimize wire area of power distribution network, these research works convey little idea on optimizing very large-scale power distribution networks (i.e. networks having more than four million nodes) using an automated environment. The originality in this research is the illustration of an automated environment equipped with an efficient optimization technique based on random probabilistic movement of water drops in solving very large-scale power distribution networks without sacrificing accuracy and additional computational cost. Based on the computation of river formation dynamics, the knowledge of minimum area bounded by optimum IR drop value can be of significant advantage in reduction of routable space and in system performance improvement.


2021 ◽  
Author(s):  
Chinmay Shah ◽  
Richard Wies

The conventional power distribution network is being transformed drastically due to high penetration of renewable energy sources (RES) and energy storage. The optimal scheduling and dispatch is important to better harness the energy from intermittent RES. Traditional centralized optimization techniques limit the size of the problem and hence distributed techniques are adopted. The distributed optimization technique partitions the power distribution network into sub-networks which solves the local sub problem and exchanges information with the neighboring sub-networks for the global update. This paper presents an adaptive spectral graph partitioning algorithm based on vertex migration while maintaining computational load balanced for synchronization, active power balance and sub-network resiliency. The parameters that define the resiliency metrics of power distribution networks are discussed and leveraged for better operation of sub-networks in grid connected mode as well as islanded mode. The adaptive partition of the IEEE 123-bus network into resilient sub-networks is demonstrated in this paper.