scholarly journals Enhancing Power System Transient Stability by Virtual Synchronous Generator Control Using Wide-Area Measurements

Author(s):  
Yiwei Ma ◽  
Lin Zhu ◽  
Fred Wang ◽  
Leon M. Tolbert
2020 ◽  
pp. 0309524X2097546
Author(s):  
Abdul Waheed Kumar ◽  
Mairaj ud din Mufti ◽  
Mubashar Yaqoob Zargar

This paper reports the modeling and dynamic performance of a wind penetrated multi-area power system incorporating a Singular Virtual Synchronous Generator (SVSG)/Distributed Virtual Synchronous Generator (DVSG). The active and reactive power controls are achieved by using Superconducting Magnetic Energy Storage (SMES) as Virtual Synchronous Generator (VSG). SMES based VSG control parameters are tuned offline using genetic algorithm (GA). Two topologies of VSGs are considered in this paper: SVSG at lowest inertia generator bus (SVSGGENBUS), SVSG at load bus (SVSGLOADBUS) and DVSG of comparatively smaller rating at three lowest inertia generator buses. A modified 18 machine, 70-bus power system is simulated in MATLAB/Simulink environment. System performance is assessed for two different types of disturbances: step wind disturbance and three-phase fault. The simulation results show that rate of change of frequency (ROCOF), deviations in frequency and voltage are minimized with DVSG. Transient stability measured in terms of critical clearing time (CCT) verifies that CCT is increased by DVSG topology.


2020 ◽  
Vol 140 (6) ◽  
pp. 531-538
Author(s):  
Kotaro Nagaushi ◽  
Atsushi Umemura ◽  
Rion Takahashi ◽  
Junji Tamura ◽  
Atsushi Sakahara ◽  
...  

Energies ◽  
2021 ◽  
Vol 14 (15) ◽  
pp. 4581
Author(s):  
Yuko Hirase ◽  
Yuki Ohara ◽  
Naoya Matsuura ◽  
Takeaki Yamazaki

In the field of microgrids (MGs), steady-state power imbalances and frequency/voltage fluctuations in the transient state have been gaining prominence owing to the advancing distributed energy resources (DERs) connected to MGs via grid-connected inverters. Because a stable, safe power supply and demand must be maintained, accurate analyses of power system dynamics are crucial. However, the natural frequency components present in the dynamics make analyses complex. The nonlinearity and confidentiality of grid-connected inverters also hinder controllability. The MG considered in this study consisted of a synchronous generator (the main power source) and multiple grid-connected inverters with storage batteries and virtual synchronous generator (VSG) control. Although smart inverter controls such as VSG contribute to system stabilization, they induce system nonlinearity. Therefore, Koopman mode decomposition (KMD) was utilized in this study for consideration as a future method of data-driven analysis of the measured frequencies and voltages, and a frequency response analysis of the power system dynamics was performed. The Koopman operator is a linear operator on an infinite dimensional space, whereas the original dynamics is a nonlinear map on a finite state space. In other words, the proposed method can precisely analyze all the dynamics of the power system, which involve the complex nonlinearities caused by VSGs.


Sign in / Sign up

Export Citation Format

Share Document