Fault Current Limiting Implementation in a Series Power Electronic Converter

Author(s):  
Kishore Akkala ◽  
Roberto Faranda ◽  
Pierfrancesco Sodini ◽  
Giambattista Gruosso
Electronics ◽  
2019 ◽  
Vol 8 (7) ◽  
pp. 795 ◽  
Author(s):  
Amir Heidary ◽  
Hamid Radmanesh ◽  
Ali Moghim ◽  
Kamran Ghorbanyan ◽  
Kumars Rouzbehi ◽  
...  

Current power systems will suffer from increasing pressure as a result of an upsurge in demand and will experience an ever-growing penetration of distributed power generation, which are factors that will contribute to a higher of incidence fault current levels. Fault current limiters (FCLs) are key power electronic devices. They are able to limit the prospective fault current without completely disconnecting in cases in which a fault occurs, for instance, in a power transmission grid. This paper proposes a new type of FCL capable of fault current limiting in two steps. In this way, the FCLs’ power electronic switches experience significantly less stress and their overall performance will significantly increase. The proposed device is essentially a controllable H bridge type fault current limiter (HBFCL) that is comprised of two variable inductances, which operate to reduce current of main switch in the first stage of current limiting. In the next step, the main switch can limit the fault current while it becomes open. Simulation studies are carried out using MATLAB and its prototype setup is built and tested. The comparison of experimental and simulation results indicates that the proposed HBFCL is a promising solution to address protection issues.


Energies ◽  
2021 ◽  
Vol 14 (14) ◽  
pp. 4157
Author(s):  
Sang-Jae Choi ◽  
Jun-Hyup Lee ◽  
Jin-Wook Lee ◽  
Sung-Hun Lim

In this paper, direct current (DC) fault current limiting and interrupting operation of hybrid DC circuit breaker (DCCB) using double quench, which consists of DCCB, a series resonance circuit, power electronic switch, surge arrestor, two separated current limiting reactor/resistor, and two superconducting elements, were suggested. The suggested hybrid DCCB can perform the interrupting operation after twice or once DC fault current limiting operation according to DC fault current amplitude. To verify the effective operation of the suggested hybrid DCCB, the modeling for the components of DCCB, the surge arrestor, and the SCE was carried out and its DC operational characteristics were analyzed. Through the analysis of the modeling results for the suggested hybrid DCCB, the advantages of hybrid DCCB were discussed.


Sign in / Sign up

Export Citation Format

Share Document