Partial discharges measurements as an on-site diagnostic tool during after-laying tests of high voltage extruded cable systems

Author(s):  
Mirza Batalovic ◽  
Mesud Hadzialic ◽  
Halid Matoruga ◽  
Nejra Batalovic

On-site PD measurements on high voltage cables have to concentrate on the cable accessories because there is a remaining risk for assembling faults on site. PD sensors with an appropriate coupling behavior to accessory-internal PD give sensitivities of a few pC or even better. Unfortunately, two main reasons prevent the general use of PD sensors in cable accessories. First of all, the costs for PD sensors have to be balanced with the costs of the accessories, importance of the cable link, consequential costs for outage etc. This is the reason why PD sensors were mainly used EHV cable systems. The second reason is limited accessibility: the PD sensor cable at the accessory has to be connected to a PD detection unit. Accessibility is much more difficult for direct buried cable systems than for cable terminations and tunnel-laid cable systems: the senor cable must pass the ground and the end up in a box on the surface to provide access. This solution causes additional costs and new problems like sealing the sensor cable against humidity, capability to withstand sheath testing etc. By looking for alternative access to PD signals from cable joints of long cable systems, a very simple solution proved suitable: detecting PD at cross-bonding links. To investigate the high frequency propagation of PD pulses in cross-bonding links, computer simulations and laboratory measurements were done.


2021 ◽  
Vol 17 (2) ◽  
pp. 155014772199928
Author(s):  
Jiajia Song ◽  
Jinbo Zhang ◽  
Xinnan Fan

Partial discharges are the major cause of deterioration in the insulation characteristics of switchgears. Therefore, timely detection of partial discharge in switchgear and potential insulation faults is an urgent problem that needs to be addressed in the power supervision industry. In this study, a device was proposed for online monitoring of high-voltage switchgears based on pulse current method and ozone (O3) detection. The pulse current method obtains the PD signal by monitoring the phase holes on the switch indicator. Occurrence of a partial discharge in a certain phase leads to the production of a discharge pulse, which can be coupled out by a capacitive sensor. The current spectrum and the O3 produced by partial discharge were processed via fast Fourier transform for accurate diagnosis of the occurrence of partial discharge and its severity in switchgears. The proposed method allows for convenient acquisition of the partial discharge signal, simple installation of the device, and realization with inexpensive sensors.


2016 ◽  
Vol 22 (2) ◽  
Author(s):  
Gediminas Dauksys ◽  
Audrius Jonaitis ◽  
Saulius Gudzius ◽  
Alfonsas Morkvenas

Sign in / Sign up

Export Citation Format

Share Document