Motion detection using wavelet-enhanced accumulative frame differencing

Author(s):  
M. N. Al-Berry ◽  
M. A.-M. Salem ◽  
A. S. Hussein ◽  
M. F. Tolba
Keyword(s):  
2016 ◽  
Vol 136 (12) ◽  
pp. 1759-1760
Author(s):  
Masao Izumi ◽  
Kenji Hashimoto
Keyword(s):  

2020 ◽  
pp. 1-10
Author(s):  
Bryce J. Dietrich

Abstract Although previous scholars have used image data to answer important political science questions, less attention has been paid to video-based measures. In this study, I use motion detection to understand the extent to which members of Congress (MCs) literally cross the aisle, but motion detection can be used to study a wide range of political phenomena, like protests, political speeches, campaign events, or oral arguments. I find not only are Democrats and Republicans less willing to literally cross the aisle, but this behavior is also predictive of future party voting, even when previous party voting is included as a control. However, this is one of the many ways motion detection can be used by social scientists. In this way, the present study is not the end, but the beginning of an important new line of research in which video data is more actively used in social science research.


Author(s):  
Jonny Nordström ◽  
Hendrik J. Harms ◽  
Tanja Kero ◽  
Jens Sörensen ◽  
Mark Lubberink

Abstract Background Patient motion is a common problem during cardiac PET. The purpose of the present study was to investigate to what extent motions influence the quantitative accuracy of cardiac 15O-water PET/CT and to develop a method for automated motion detection. Method Frequency and magnitude of motion was assessed visually using data from 50 clinical 15O-water PET/CT scans. Simulations of 4 types of motions with amplitude of 5 to 20 mm were performed based on data from 10 scans. An automated motion detection algorithm was evaluated on clinical and simulated motion data. MBF and PTF of all simulated scans were compared to the original scan used as reference. Results Patient motion was detected in 68% of clinical cases by visual inspection. All observed motions were small with amplitudes less than half the LV wall thickness. A clear pattern of motion influence was seen in the simulations with a decrease of myocardial blood flow (MBF) in the region of myocardium to where the motion was directed. The perfusable tissue fraction (PTF) trended in the opposite direction. Global absolute average deviation of MBF was 3.1% ± 1.8% and 7.3% ± 6.3% for motions with maximum amplitudes of 5 and 20 mm, respectively. Automated motion detection showed a sensitivity of 90% for simulated motions ≥ 10 mm but struggled with the smaller (≤ 5 mm) simulated (sensitivity 45%) and clinical motions (accuracy 48%). Conclusion Patient motion can impair the quantitative accuracy of MBF. However, at typically occurring levels of patient motion, effects are similar to or only slightly larger than inter-observer variability, and downstream clinical effects are likely negligible.


Sign in / Sign up

Export Citation Format

Share Document