The effect of contaminant in breakdown time lag of uniform electric field using impulse breakdown in mineral oil

Author(s):  
H. Naoshi ◽  
O.A. Aloys ◽  
A. Kiyomitsu
2014 ◽  
Vol 989-994 ◽  
pp. 1273-1277
Author(s):  
Chang Ming Li ◽  
Bao Zhong Han ◽  
Long Zhao ◽  
Chun Peng Yin

Nonlinear insulated materials can uniform electric field distribution in non-uniform electric field. In order to inhibit the electric tree initiation and propagation inside high-voltage cross-linked polyethylene (XLPE) insulated cable, a kind of 220kV high-voltage XLPE insulated cable with new structure is designed by embedding nonlinear shielding layer into XLPE insulation layer of high-voltage cable with traditional structure in this study. Experimental and simulation results indicate that the nonlinear shielding layer can effectively inhibit electrical tree propagation inside the XLPE specimens, and obviously extend the breakdown time caused by electric tree propagation. When the electrical tree propagates into the nonlinear shielding layer sandwiched between insulation layers of cable, the electric field distribution near the tip of electrical tree is obviously improved. These findings prove the feasibility and the effectivity of inhibiting electrical tree propagation inside high-voltage cable by adding nonlinear shielding layer into the insulation layer.


1998 ◽  
Vol 37 (Part 1, No. 9A) ◽  
pp. 4884-4886 ◽  
Author(s):  
Naoshi Hirai ◽  
Aloys Akumu ◽  
Kiyomitsu Arii
Keyword(s):  
Time Lag ◽  

Energies ◽  
2020 ◽  
Vol 13 (18) ◽  
pp. 4830
Author(s):  
Alper Aydogan ◽  
Fatih Atalar ◽  
Aysel Ersoy Yilmaz ◽  
Pawel Rozga

In high-voltage equipment, it is vital to detect any failure in advance. To do this, a determination of the partial discharges occurring at different voltage types as well as at different electrode configurations is essential for observing the oil condition. In this study, an experimental setup consisting of a needle–semi-sphere electrode configuration immersed in mineral oil is prepared for laboratory experiment. In such a way, a non-uniform electric field is created and the leakage currents are monitored from the grounded electrode. A total of six different electrode configurations are analyzed during the tests by the use of hemispheres of different diameters as grounded electrodes and copper and steel pointed (medical) needle high-voltage electrodes. In the experiments, the partial discharges occurring at four different voltage levels between 5.4 and 10.8 kV are measured and recorded. The effect of the different electrode configurations and voltage levels on the harmonic distortion are noted and discussed. It is experimentally confirmed that it is possible to measure the leakage current caused by the partial discharges of the corona type in oil at the different metal points, creating high-voltage electrodes and different electric field distributions based on the proposed non-invasive measurement technique. The studies showed that there is a significant rise of even harmonic components in the leakage current during the increase in the partial discharge intensity with the 5th harmonic as dominant.


1997 ◽  
Vol 117 (11) ◽  
pp. 1109-1114
Author(s):  
Yoshiyuki Suda ◽  
Kenji Mutoh ◽  
Yosuke Sakai ◽  
Kiyotaka Matsuura ◽  
Norio Homma

2008 ◽  
Vol 128 (12) ◽  
pp. 1445-1451
Author(s):  
Takanori Yasuoka ◽  
Tomohiro Kato ◽  
Katsumi Kato ◽  
Hitoshi Okubo

2021 ◽  
Vol 28 (2) ◽  
pp. 333-340
Author(s):  
S. Diaham ◽  
Z. Valdez-Nava ◽  
L. Leveque ◽  
T. T. Le ◽  
L. Laudebat ◽  
...  