A Low-Cost Two-Dimensional Near-Field Imaging System Based on a Goubau Line

Author(s):  
Dingfei Ma ◽  
Qingfeng Zhang ◽  
Amir Khurrum Rasahid ◽  
Xiaolan Tang
Author(s):  
Anatoliy O. Boryssenko ◽  
Christophe Craeye ◽  
Daniel H. Schaubert

Nanoscale ◽  
2019 ◽  
Vol 11 (30) ◽  
pp. 14113-14117 ◽  
Author(s):  
Mengfei Xue ◽  
Qi Zheng ◽  
Runkun Chen ◽  
Lihong Bao ◽  
Shixuan Du ◽  
...  

Near-field imaging of mid-infrared waveguide in SnSe2 slabs promotes two-dimensional van der Waals materials as building blocks for integrated MIR chips.


Author(s):  
Michael Boyarsky ◽  
Timothy Sleasman ◽  
Laura Pulido-Mancera ◽  
Aaron V. Diebold ◽  
Mohammadreza F. Imani ◽  
...  

2015 ◽  
Vol 9 (10) ◽  
pp. 1009-1014 ◽  
Author(s):  
Malyhe Jalilvand ◽  
Xuyang Li ◽  
Lukasz Zwirello ◽  
Thomas Zwick

Photonics ◽  
2021 ◽  
Vol 8 (5) ◽  
pp. 143
Author(s):  
Xin Yu ◽  
Yun Shen ◽  
Guohong Dai ◽  
Liner Zou ◽  
Tailin Zhang ◽  
...  

We experimentally demonstrate that high-resolution terahertz focusing can be realized in planar metalenses, which consist of arrays of different V-shaped antenna units on a silicon substrate. Numerical results show that a larger numerical aperture of metalenses can provide smaller full width at half maximum of field distribution, leading to higher spatial resolution. The measurement of fabricated metalenses samples was performed by a terahertz near-field imaging system, and experimental results agree well with the numerical prediction. Especially for 1.1 THz incident light, when the numerical aperture increases from 0.79 to 0.95, the full width at half maximum correspondingly decreases from 343 μm to 206 μm, offering an improvement of spatial resolution.


Author(s):  
G. S. Kino ◽  
S. Hayashi ◽  
I. Ichimura

Some time ago, we described a new type of near-field imaging system using the Solid Immersion Lens. A confocal microscope using this principle has demonstrated sub-100 nm resolution with visible light. In this paper, we will describe how this device is being applied to increasing the density of optical storage in CD ROMs and magneto-optical storage systems.The SIL is placed between the objective and the disk. As illustrated in Fig. 1(a), if the SIL is in the form of a hemisphere, rays enter it along its radii and converge at its center. If the refractive index of the SIL is n, the wavelength in this material is reduced by 1/n and consequently increases the effective NA of the objective lens by the refractive index n and decreases the spot size by 1/n. With this configuration, we were able to obtain good quality images of a grating with 100 nm gaps and strip widths.


Nano Letters ◽  
2015 ◽  
Vol 15 (2) ◽  
pp. 1122-1127 ◽  
Author(s):  
Samuel Berweger ◽  
Joel C. Weber ◽  
Jimmy John ◽  
Jesus M. Velazquez ◽  
Adam Pieterick ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document