All-fiber linear sampling device for absolute distance measurement

Author(s):  
Chunze Wang ◽  
Jiaqi Wang ◽  
Guanyu Liu ◽  
Ziling Wu ◽  
Youjian Song ◽  
...  
2016 ◽  
Vol 56 (2) ◽  
pp. 88 ◽  
Author(s):  
Filip Dvořáček

<p>This paper describes laboratory tests on a Leica AT401laser tracker. As the newer Leica AT402 model also uses the same firmware package, most of the results should also be valid for this device. First, we present the instrument’s firmware errors and the software used for testing. The ASME B89.4.19-2006 standard for testing laser trackers is briefly presented. The warm-up effect of the instrument is inspected with respect to both angle measurement and distance measurement. The absolute distance meter (ADM) is compared with a laboratory interferometer on a 30-meter long rail and also on a bench with automated movement of the carriage of the reflector. A time series of measurements for determining the additive constant is evaluated. A simple test of the stability of the distance measurement in field conditions is introduced. Most of the tests were carried out at the Research Institute of Geodesy, Topography and Cartography (RIGTC) and at the Faculty of Civil Engineering (FCE) of the Czech Technical University in Prague (CTU).</p>


2017 ◽  
Vol 111 (19) ◽  
pp. 191104 ◽  
Author(s):  
Karl Meiners-Hagen ◽  
Tobias Meyer ◽  
Jutta Mildner ◽  
Florian Pollinger

2011 ◽  
Vol 31 (3) ◽  
pp. 0314001
Author(s):  
李志栋 Li Zhidong ◽  
江月松 Jiang Yuesong ◽  
桑峰 Sang Feng ◽  
王林春 Wang Linchun ◽  
邓士光 Deng Shiguang ◽  
...  

2015 ◽  
Vol 35 (s2) ◽  
pp. s212001
Author(s):  
许立明 Xu Liming ◽  
宋有建 Song Youjian ◽  
梁飞 Liang Fei ◽  
师浩森 Shi Haosen ◽  
胡明列 Hu Minglie ◽  
...  

2020 ◽  
Vol 238 ◽  
pp. 06011
Author(s):  
Jan Spichtinger ◽  
Michael Schulz ◽  
Gerd Ehret

We are developing a form measurement system for the surfaces of freeform optics and large conventional optics. The specifications of the optics are diameters up to 1.5 m and radii of curvature down to 10 m. This includes optics like telescope mirror segments and synchrotron optics. Using a Fizeau interferometer, we propose a subaperture stitching method that involves vertically aligning the interferometer’s optical axis to the local surface gradient and measuring the absolute distance from the interferometer’s reference flat to the specimen. Experimental results for the absolute distance measurement are shown.


2019 ◽  
Vol 123 ◽  
pp. 20-27
Author(s):  
Meiyun Chen ◽  
Shengli Xie ◽  
Guoxu Zhou ◽  
Dong Wei ◽  
Heng Wu ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document