Design of a Real-Time Heart Rate Monitoring System Using Photoplethysmography and Smartphone

Author(s):  
Neharika Singh ◽  
Aashirvad Prince ◽  
Swarnendu Chattopadhyay ◽  
Rusha Patra ◽  
Banibrata Mukherjee
2013 ◽  
Vol 8 (2) ◽  
pp. 376-384 ◽  
Author(s):  
Seung-Min Park ◽  
Jun-Yeup Kim ◽  
Kwang-Eun Ko ◽  
In-Hun Jang ◽  
Kwee-Bo Sim

2018 ◽  
Vol 63 ◽  
pp. 75-84 ◽  
Author(s):  
Davorin Kofjač ◽  
Radovan Stojanović ◽  
Andrej Koložvari ◽  
Andrej Škraba

2020 ◽  
Author(s):  
Suchitra Giri ◽  
Ujjwal Kumar ◽  
Varsha Sharma ◽  
Satish Kumar ◽  
Sikha Kumari ◽  
...  

Sensors ◽  
2021 ◽  
Vol 21 (3) ◽  
pp. 999
Author(s):  
Henry Dore ◽  
Rodrigo Aviles-Espinosa ◽  
Zhenhua Luo ◽  
Oana Anton ◽  
Heike Rabe ◽  
...  

Heart rate monitoring is the predominant quantitative health indicator of a newborn in the delivery room. A rapid and accurate heart rate measurement is vital during the first minutes after birth. Clinical recommendations suggest that electrocardiogram (ECG) monitoring should be widely adopted in the neonatal intensive care unit to reduce infant mortality and improve long term health outcomes in births that require intervention. Novel non-contact electrocardiogram sensors can reduce the time from birth to heart rate reading as well as providing unobtrusive and continuous monitoring during intervention. In this work we report the design and development of a solution to provide high resolution, real time electrocardiogram data to the clinicians within the delivery room using non-contact electric potential sensors embedded in a neonatal intensive care unit mattress. A real-time high-resolution electrocardiogram acquisition solution based on a low power embedded system was developed and textile embedded electrodes were fabricated and characterised. Proof of concept tests were carried out on simulated and human cardiac signals, producing electrocardiograms suitable for the calculation of heart rate having an accuracy within ±1 beat per minute using a test ECG signal, ECG recordings from a human volunteer with a correlation coefficient of ~ 87% proved accurate beat to beat morphology reproduction of the waveform without morphological alterations and a time from application to heart rate display below 6 s. This provides evidence that flexible non-contact textile-based electrodes can be embedded in wearable devices for assisting births through heart rate monitoring and serves as a proof of concept for a complete neonate electrocardiogram monitoring system.


2016 ◽  
Vol 37 (11) ◽  
pp. 1885-1909 ◽  
Author(s):  
Mojtaba Jafari Tadi ◽  
Eero Lehtonen ◽  
Tero Hurnanen ◽  
Juho Koskinen ◽  
Jonas Eriksson ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document