scholarly journals Characterisation of Textile Embedded Electrodes for Use in a Neonatal Smart Mattress Electrocardiography System

Sensors ◽  
2021 ◽  
Vol 21 (3) ◽  
pp. 999
Author(s):  
Henry Dore ◽  
Rodrigo Aviles-Espinosa ◽  
Zhenhua Luo ◽  
Oana Anton ◽  
Heike Rabe ◽  
...  

Heart rate monitoring is the predominant quantitative health indicator of a newborn in the delivery room. A rapid and accurate heart rate measurement is vital during the first minutes after birth. Clinical recommendations suggest that electrocardiogram (ECG) monitoring should be widely adopted in the neonatal intensive care unit to reduce infant mortality and improve long term health outcomes in births that require intervention. Novel non-contact electrocardiogram sensors can reduce the time from birth to heart rate reading as well as providing unobtrusive and continuous monitoring during intervention. In this work we report the design and development of a solution to provide high resolution, real time electrocardiogram data to the clinicians within the delivery room using non-contact electric potential sensors embedded in a neonatal intensive care unit mattress. A real-time high-resolution electrocardiogram acquisition solution based on a low power embedded system was developed and textile embedded electrodes were fabricated and characterised. Proof of concept tests were carried out on simulated and human cardiac signals, producing electrocardiograms suitable for the calculation of heart rate having an accuracy within ±1 beat per minute using a test ECG signal, ECG recordings from a human volunteer with a correlation coefficient of ~ 87% proved accurate beat to beat morphology reproduction of the waveform without morphological alterations and a time from application to heart rate display below 6 s. This provides evidence that flexible non-contact textile-based electrodes can be embedded in wearable devices for assisting births through heart rate monitoring and serves as a proof of concept for a complete neonate electrocardiogram monitoring system.

2013 ◽  
Vol 89 (12) ◽  
pp. 943-948 ◽  
Author(s):  
Lonneke A.M. Aarts ◽  
Vincent Jeanne ◽  
John P. Cleary ◽  
C. Lieber ◽  
J. Stuart Nelson ◽  
...  

2002 ◽  
Vol 21 (2) ◽  
pp. 61-62 ◽  
Author(s):  
Denise Maguire

When nurses work in the same neonatal intensive care unit for many years, they tend to follow routines. They follow their schedule in a certain way, report to the next shift in a certain way, and proceed with their workload in a certain, predictable way. Because many of us are creatures of habit, the routines of the unit can be comforting. We like to know what to expect. Especially in a busy NICU, often subject to unknowns from the high-risk antepartum unit, the delivery room, and community hospitals, we relish the complacency of that which we can control.


Author(s):  
Anthony Debay ◽  
Sharina Patel ◽  
Pia Wintermark ◽  
Martine Claveau ◽  
François Olivier ◽  
...  

Objective The study aimed to assess the association of tracheal intubation (TI) and where it is performed, and the number of TI attempts with death and/or severe neurological injury (SNI) among preterm infants. Study Design Retrospective cohort study of infants born 23 to 32 weeks, admitted to a single level-3 neonatal intensive care unit (NICU) between 2015 and 2018. Exposures were location of TI (delivery room [DR] vs. NICU) and number of TI attempts (1 vs. >1). Primary outcome was death and/or SNI (intraventricular hemorrhage grade 3–4 and/or periventricular leukomalacia). Multivariable logistic regression analysis was used to assess association between exposures and outcomes and to adjust for confounders. Results Rate of death and/or SNI was 2.5% (6/240) among infants never intubated, 12% (13/105) among NICU TI, 32% (31/97) among DR TI, 20% (17/85) among infants with one TI attempt and 23% (27/117) among infants with >1 TI attempt. Overall, median number of TI attempts was 1 (interquartile range [IQR]: 1–2). Compared with no TI, DR TI (adjusted odds ratio [AOR]: 9.04, 95% confidence interval [CI]: 3.21–28.84) and NICU TI (AOR: 3.42, 95% CI: 1.21–10.61) were associated with higher odds of death and/or SNI. The DR TI was associated with higher odds of death and/or SNI compared with NICU TI (AOR: 2.64, 95% CI: 1.17–6.22). The number of intubation attempts (1 vs. >1) was not associated with death and/or SNI (AOR: 0.95, 95% CI: 0.47–2.03). Conclusion The DR TI is associated with higher odds of death and/or SNI compared with NICU TI, and may help identify higher risk infants. There was no association between the number of TI attempts and death and/or SNI. Key Points