Voltage and Frequency Regulation for Wound Rotor Synchronous Generator in Micro Hydro Power Plants with Real-Time Implementation

Author(s):  
Duy An Pham ◽  
Frederic Nollet ◽  
Najib Essounbouli ◽  
Abdelaziz Hamzaoui
Energies ◽  
2021 ◽  
Vol 14 (11) ◽  
pp. 3201
Author(s):  
Henry Bory ◽  
Jose L. Martin ◽  
Iñigo Martinez de Alegria ◽  
Luis Vazquez

Micro-hydro power plants (μHPPs) are a major energy source in grid-isolated zones because they do not require reservoirs and dams to be built. μHPPs operate in a standalone mode, but a continuously varying load generates voltage unbalances and frequency fluctuations which can cause long-term damage to plant components. One method of frequency regulation is the use of alternating current-alternating current (AC-AC) converters as an electronic load controller (ELC). The disadvantage of AC-AC converters is reactive power consumption with the associated decrease in both the power factor and the capacity of the alternator to deliver current. To avoid this disadvantage, we proposed two rectifier topologies combined with symmetrical switching. However, the performance of the frequency regulation loop with each topology remains unknown. Therefore, the objective of this work was to evaluate the performance of the frequency regulation loop when each topology, with a symmetrical switching form, was inserted. A MATLAB® model was implemented to simulate the frequency loop. The results from a μHPP case study in a small Cuban rural community called ‘Los Gallegos’ showed that the performance of the frequency regulation loop using the proposed topologies satisfied the standard frequency regulation and increased both the power factor and current delivery capabilities of the alternator.


2019 ◽  
Vol 11 (2) ◽  
pp. 129-137
Author(s):  
Nurul Dyah Pratiwi ◽  
Isdiyato Isdiyato

Microhydro power plant (MPP) is a small-scale power plant that uses water energy. The process of energy change occurs in a device called a synchronous generator. when the synchronous generator is given an arbitrary load, then the voltage will change. These results cause voltage and frequency instability. This research was conducted to analyze the voltage and frequency instability in MPP. The research method used in this research is descriptive quantitative approach in the village of Soko Kembang, Petungkriyono District, Pekalongan Regency, Central Java. This study provides an overview and explanation of the problems regarding the voltage and frequency instability of Micro Hydro Power Plants. The results of this study are the highest and lowest voltage / frequency instability values, namely 235 volts / 51 Hz and 160 volts / 44 Hz, due to the influence of changes in load current, which can affect the rotational speed of the generator changes, resulting in unstable voltage and frequency generated by the generator, the rotational speed of the generator changes, resulting in unstable voltage and frequency generated by the generator. The solution is  add water power to rotate the shaft of the turbine and generator to be tighter, so that it can reduce the value of the decrease in electric power by losses to the turbine and generator. Large electric power can increase voltage and frequency without having to adjust the load, and the need for improvement of the ELC system in order to get a more effective value of voltage and frequency stability.  


2018 ◽  
Vol 73 ◽  
pp. 01017
Author(s):  
Ignatius Sriyana

Land degradation on the upstream of watershed will affect hydrology condition in a way that it will disrupt the sustainability of its existing micro hydro. The purpose of this study is to evaluate micro hydro power plant in central Java toward sustainability against hydrology condition of watershed. This study is using River Regime Coefficient (RRC) approach where hydrology of watershed with coefficient value less than 50 is classified as non-critical, between 50 and 120 is moderate and more than 120 is critical. Result of the study that was done on 33 micro hydro power plants scattered on 9 watersheds is showing that there are 2 power plants on 2 watersheds have hydrology condition in non-critical status (9.09%), 1 power plant on 1 watershed is in between critical and non-critical status (3.03%), 21 power plants on 3 watersheds are in between critical and moderate status (63.64%), 8 power plants on 6 watersheds are in critical status (21.21%) and 1 power plant on 1 watershed is in between moderate and critical status (3.03%).


Sign in / Sign up

Export Citation Format

Share Document