Analysis of the Sandia Frequency Shift (SFS) islanding detection method with a single-phase photovoltaic distributed generation system

Author(s):  
Marcos V. G. Reis ◽  
Tarcio A. S. Barros ◽  
Adson B. Moreira ◽  
Paulo S. Nascimento F. ◽  
Ernesto Ruppert F. ◽  
...  
2013 ◽  
Vol 318 ◽  
pp. 597-600
Author(s):  
Dong Xie ◽  
Xing Zhang

In the area of renewable energy technologies, islanding of distributed generation system needs to be prevented due to safety reasons and to ensure quality of power supplied to the customers. Several islanding detection methods based on passive and active schemes have been proposed in the literature. Passive methods have a large non detection zone (NDZ), While active schemes degrade power quality. This paper proposed a new passive islanding detection method which combines the Wavelet-transform and neural network techniques. This method can reduce the NDZ to zero without any perturbation that deteriorates the power quality. The simulation results show that the proposed islanding detection method is effective and robust in all kind of conditions.


2018 ◽  
Vol 7 (1.8) ◽  
pp. 228 ◽  
Author(s):  
Gundala Srinivasa Rao ◽  
G. Kesava Rao

The penetration of Distributed generation (DG) ensures the increase of demand for consistent, reasonable and spotless electricity facing with some design and operational challenges such as islanding. Several active and passive methods have been suggested in the past to detect islanding. Since they suffer from the large non detection zone and a high cost. In order to defeat such issues we propose a SVM based pattern recognising approach for islanding detection in a multiple DG system. The results show that our proposed method detects islanding with high accuracy.


2017 ◽  
Vol 8 (4) ◽  
pp. 1821-1830 ◽  
Author(s):  
Qinfei Sun ◽  
Josep M. Guerrero ◽  
Tianjun Jing ◽  
Juan C. Vasquez ◽  
Rengang Yang

2015 ◽  
Vol 2015 ◽  
pp. 1-11 ◽  
Author(s):  
Manop Yingram ◽  
Suttichai Premrudeepreechacharn

The mainly used local islanding detection methods may be classified as active and passive methods. Passive methods do not perturb the system but they have larger nondetection zones, whereas active methods have smaller nondetection zones but they perturb the system. In this paper, a new hybrid method is proposed to solve this problem. An over/undervoltage (passive method) has been used to initiate an undervoltage shift (active method), which changes the undervoltage shift of inverter, when the passive method cannot have a clear discrimination between islanding and other events in the system. Simulation results on MATLAB/SIMULINK show that over/undervoltage and undervoltage shifts of hybrid islanding detection method are very effective because they can determine anti-islanding condition very fast.ΔP/P>38.41% could determine anti-islanding condition within 0.04 s;ΔP/P<-24.39% could determine anti-islanding condition within 0.04 s;-24.39%≤ΔP/P≤ 38.41% could determine anti-islanding condition within 0.08 s. This method perturbed the system, only in the case of-24.39% ≤ΔP/P ≤38.41% at which the control system of inverter injected a signal of undervoltage shift as necessary to check if the occurrence condition was an islanding condition or not.


Solar Energy ◽  
2013 ◽  
Vol 97 ◽  
pp. 155-167 ◽  
Author(s):  
Ku Nurul Edhura Ku Ahmad ◽  
Nasrudin Abd Rahim ◽  
Jeyraj Selvaraj ◽  
Ahmad Rivai ◽  
Krismadinata Chaniago