Study of Petersen Coil Grounding System Inductance Variation on Ferroresonance in 150 kV Transformer

Author(s):  
I Gusti Ngurah Satriyadi Hernanda ◽  
I Made Yulistya Negara ◽  
Dimas Anton Asfani ◽  
Daniar Fahmi ◽  
Mochammad Wahyudi ◽  
...  
2014 ◽  
Vol 620 ◽  
pp. 394-397
Author(s):  
Xiang Dong Zhao ◽  
Feng Zhen Liu ◽  
Ye Tian

While the system is equipped with Petersen coil caused by the switching operation can prevent a different period , single-phase disconnection and other factors neutral point displacement , so that the neutral point voltage is too high, the threat of insulation safety equipment . Also in the normal operation of the power grid , but also effectively prevent resonance over-voltage , prevent system damage caused thereby , better protection of system security , stability, and high-quality operation. Summary of small current grounding system after the formation of arc suppression coil compensation compensation network system , in order to better prevent arc short-circuiting the system of single phase , which is to ensure security of supply , improve reliability and power quality .In the paper, small current grounding system Petersen coil with the compensation adjustment is carried out and some analysis, study and research is done in order to improve the operating personnel awareness and emphasis on small current grounding system , and better ensure the safety of the small current grounding system , stable operation.


Author(s):  
Hitoshi Hayashiya ◽  
Norio Koguchi ◽  
Hiroshi Yamamoto ◽  
Takashi Ozaki ◽  
Takashi Sakurai ◽  
...  

Energies ◽  
2021 ◽  
Vol 14 (14) ◽  
pp. 4118
Author(s):  
I Made Yulistya Negara ◽  
Daniar Fahmi ◽  
Dimas Anton Asfani ◽  
IGN Satriyadi Hernanda ◽  
Rendi Bagus Pratama ◽  
...  

In this study, the lightning protection system and grounding system of one plant of the petrochemical industry were investigated, evaluated, and improved. The methods used in this study were rolling sphere and angle protection methods. The grounding system of the building under study was modeled and simulated using ATP/EMTP (Alternative Transient Program/Electromagnetic Transient Program) software. The results show that the external lightning protection system of the prilling tower studied does not adhere to IEC 62305 and IEC 1024-1-1 standards. Moreover, the grounding configuration of the DCS building was not appropriate for protecting sensitive equipment inside. Lightning causes an enormous potential difference between lightning ground rods in the grounding system. Additionally, disabling the existing surge protective device (SPD) causes an increase in the magnitude of Ground Potential Rise at the DCS building. Improvement of the lightning protection system of the prilling tower and DCS building on Plant 1 of this petrochemical company as well as some other recommendations for improvements are proposed. This paper also shows evidence that external lightning protection, internal lightning protection, and the grounding system need to be connected to make an exemplary lightning protection system.