Fabrication of Capacitive Micromachined Ultrasonic Transducer Arrays With Isolation Trenches Using Anodic Wafer Bonding

2015 ◽  
Vol 15 (9) ◽  
pp. 5177-5184 ◽  
Author(s):  
Ravindra Mukhiya ◽  
Aditi ◽  
K. Prabakar ◽  
M. Raghuramaiah ◽  
J. Jayapandian ◽  
...  
Ultrasonics ◽  
2002 ◽  
Vol 40 (1-8) ◽  
pp. 471-476 ◽  
Author(s):  
Jeremy Johnson ◽  
Ömer Oralkan ◽  
Utkan Demirci ◽  
Sanlı Ergun ◽  
Mustafa Karaman ◽  
...  

2007 ◽  
Vol 138 (1) ◽  
pp. 221-229 ◽  
Author(s):  
Xuefeng Zhuang ◽  
Arif S. Ergun ◽  
Yongli Huang ◽  
Ira O. Wygant ◽  
Omer Oralkan ◽  
...  

Micromachines ◽  
2019 ◽  
Vol 10 (5) ◽  
pp. 319 ◽  
Author(s):  
Mansoor Ahmad ◽  
Ayhan Bozkurt ◽  
Omid Farhanieh

This article presents a new wafer-bonding fabrication technique for Capacitive Micromachined Ultrasonic Transducers (CMUTs) using polymethyl methacrylate (PMMA). The PMMA-based single-mask and single-dry-etch step-bonding device is much simpler, and reduces process steps and cost as compared to other wafer-bonding methods and sacrificial-layer processes. A low-temperature (< 180 ∘ C ) bonding process was carried out in a purpose-built bonding tool to minimize the involvement of expensive laboratory equipment. A single-element CMUT comprising 16 cells of 2.5 mm radius and 800 nm cavity was fabricated. The center frequency of the device was set to 200 kHz for underwater communication purposes. Characterization of the device was carried out in immersion, and results were subsequently validated with data from Finite Element Analysis (FEA). Results show the feasibility of the fabricated CMUTs as receivers for underwater applications.