High-Performance of Al Nanoparticle Enhanced 4H-SiC MSM Photodiodes for Deep Ultraviolet Detection

2017 ◽  
Vol 38 (10) ◽  
pp. 1405-1408 ◽  
Author(s):  
Shao-Xiong Liu ◽  
Tao Wang ◽  
Zhi-Zhan Chen
1987 ◽  
Vol 33 (8) ◽  
pp. 1427-1430 ◽  
Author(s):  
R Sakuma ◽  
T Nishina ◽  
M Kitamura

Abstract We evaluated six deproteinizing methods for determination of uric acid in serum by "high-performance" liquid chromatography with ultraviolet detection: those involving zinc hydroxide, sodium tungstate, trichloroacetic acid, perchloric acid, acetonitrile, and centrifugal ultrafiltration (with Amicon MPS-1 devices). We used a Toyosoda ODS-120A reversed-phase column. The mobile phase was sodium phosphate buffer (40 mmol/L, pH 2.2) containing 20 mL of methanol per liter. Absorbance of the eluate was monitored at 284 nm. The precipitation method with perchloric acid gave high recoveries of uric acid and good precision, and results agreed with those by the uricase-catalase method of Kageyama (Clin Chim Acta 1971;31:421-6).


2021 ◽  
pp. 1-1
Author(s):  
Jianmiao Guo ◽  
Minghe Ma ◽  
Yuqiang Li ◽  
Dan Zhang ◽  
Yanghui Liu ◽  
...  

2014 ◽  
Vol 29 (4) ◽  
pp. 537-544 ◽  
Author(s):  
Marco Antônio dos. Reis Júnior ◽  
Ana Cláudia Miranda de Faria ◽  
Eudes da. Silva Velozo ◽  
Teresa Dalla Costa ◽  
Frank Pereira de Andrade ◽  
...  

Author(s):  
Mahmoud A Tantawy ◽  
Israa A Wahba ◽  
Samah S Saad ◽  
Nesrin K Ramadan

Abstract Two sensitive, selective and precise chromatographic methods have been established for concomitant quantification of ciprofloxacin HCl (CIP), fluocinolone acetonide (FLU) along with ciprofloxacin impurity A (CIP-imp A). The first method was thin-layer chromatography (TLC-densitometry) where separation was accomplished using TLC silica plates 60 G.F254 as a stationary phase and chloroform–methanol–33%ammonia (4.6:4.4:1, by volume) as a developing system. The obtained plates were scanned at 260 nm over concentration ranges of 1.0–40.0, 0.6–20.0 and 1.0–40.0 μg band−1 for CIP, FLU and CIP-imp A, respectively. The second method was based on high-performance liquid chromatography using a Zorbax ODS column (5 μm, 150 × 4.6 mm i.d.) where adequate separation was achieved through a mobile phase composed of phosphate buffer pH 3.6–acetonitrile (45:55, v/v) at flow rate 1.0 mL min−1 with ultraviolet detection at 254 nm. Linear regressions were obtained in the range of 1.0–40.0 μg mL−1 for CIP, 0.6–20.0 μg mL−1 for FLU and 1.0–40.0 μg mL−1 for CIP-imp A. The suggested methods were validated in compliance with the International Conference on Harmonization guidelines and were successfully applied for determination of CIP and FLU in bulk powder and newly marketed otic solution.


Sign in / Sign up

Export Citation Format

Share Document