Excitation power dependence of photoluminescence spectra of CdTe on InSb grown by molecular-beam epitaxy

Author(s):  
W.Y. Chang ◽  
Z.C. Feng ◽  
S.J. Chua ◽  
J. Lin
Author(s):  
F. J. Sánchez ◽  
F. Calle ◽  
M.A. Sanchez-Garcia ◽  
E. Calleja ◽  
E. Muñoz ◽  
...  

Low temperature photoluminescence spectra of Be-doped layers grown on Si (111) by molecular beam epitaxy have been analyzed. Emissions at 3.466 eV and 3.384 eV, and a broad band centered at 2.4-2.5 eV are observed. Their evolution with temperature and excitation power, and time resolved PL measurements ascribe an excitonic character for the luminescence at 3.466 eV, whereas the emission at 3.384 eV is associated with a donor-acceptor pair transition. This recombination involves residual donors and Be-related acceptors, which are located around 90meV above the valence band, confirming Be as the shallowest acceptor reported in GaN. The intensity of the band at 2.4-2.5 eV increases with the Be content. This emission involves a band of deep acceptors generated by Be complex defects, as suggested by the parameter g = 2.008 ± 0.003 obtained by photoluminescence-detected electron paramagnetic resonance.


1989 ◽  
Vol 39 (5) ◽  
pp. 3138-3144 ◽  
Author(s):  
Katsuhiro Akimoto ◽  
Takao Miyajima ◽  
Yoshifumi Mori

1986 ◽  
Vol 59 (3) ◽  
pp. 888-891 ◽  
Author(s):  
Kazuhiro Kudo ◽  
Yunosuke Makita ◽  
Ichiro Takayasu ◽  
Toshio Nomura ◽  
Toshihiko Kobayashi ◽  
...  

1991 ◽  
Vol 240 ◽  
Author(s):  
A. G. Choo ◽  
H. E. Jackson ◽  
P. Chen ◽  
A. J. Steckl ◽  
V. Gupta ◽  
...  

ABSTRACTLow temperature photoluminescence spectra have been used to characterize conventional ion beam (CIB) and focused ion beam (FIB) implanted superlattices. The excitation dependence of the single scan FIB is found to be significantly different from CIB and multiple scan FIB implantations which are similar. The peak position of the donor-acceptor transition is observed to change to higher energies significantly slower with excitation intensity for the single scan FIB case when compared to the multiple scan FIB and CIB cases. Simple models to describe these effects are briefly discussed.


2006 ◽  
Vol 3 (6) ◽  
pp. 1870-1873
Author(s):  
Tohru Honda ◽  
Masaru Sawada ◽  
Toshiaki Kobayashi ◽  
Shinichi Egawa ◽  
Yohta Aoki ◽  
...  

1992 ◽  
Vol 61 (13) ◽  
pp. 1540-1542 ◽  
Author(s):  
Jie Cui ◽  
Hai‐Long Wang ◽  
Fu‐Xi Gan ◽  
Xu‐Guang Huang ◽  
Zhi‐Gang Cai ◽  
...  

Sign in / Sign up

Export Citation Format