Implementation of a measurement system for analysing the spectral radiation pattern of light sources with low divergence

Author(s):  
Nacira Stiebler ◽  
Pirmin Pezzei ◽  
Andreas Merdonig ◽  
Erich Leitgeb
2013 ◽  
Author(s):  
Pirmin Pezzei ◽  
Nacira Stiebler ◽  
Thomas Plank ◽  
Juraj Poliak ◽  
Erich Leitgeb ◽  
...  

Electronics ◽  
2019 ◽  
Vol 8 (4) ◽  
pp. 451 ◽  
Author(s):  
Liuzheng Ma ◽  
Zhenfeng Li ◽  
Zephania Birech ◽  
Shixin Li ◽  
Yatao Yang ◽  
...  

To solve the problems that occur when farmers overuse chemical fertilizers, it is necessary to develop rapid and efficient portable measurement systems for the detection and quantification of nitrogen (N), phosphorus (P), and potassium (K) in soil. Challenges arise from the use of currently available portable instruments which only have a few channels, namely measurement and the reference channels. We report on a home-built, multichannel, optoelectronic measurement system with automatically switching light sources for the detection of N, P, K content in soil samples. This optoelectronic measurement system consists of joint LED light sources with peak emission wavelengths of 405 nm, 660 nm, and 515 nm, a photodiode array, a circuit board with a microcontroller unit (MCU), and a liquid-crystal display (LCD) touch screen. The straightforward principle for rapid detection of the extractable nutrients (N, P, K) was well-established, and characterization of the designed measurement system was done. Using this multi-channel measurement system, available nutrients extracted from six soil samples could be measured simultaneously. The absorbance compensation, concentration calibration, and nutrition measurements were performed automatically to achieve high consistency across six channels. The experimental results showed that the cumulative relative standard deviations of 1.22%, 1.27%, and 1.00% were obtained from six channels with known concentrations of standard solutions, respectively. The coefficients of correlation for the detection of extracted nutrients of N, P, K content in soil samples using both the proposed method and conventional lab-based method were 0.9010, 0.9471, and 0.8923, respectively. Experimental results show that this optoelectronic measurement system can perform the measurement of N, P, K contents of six soil samples simultaneously and may be used as an actual tool in determining nutrients in soil samples with an improvement in detection efficiency.


2011 ◽  
Vol 411 ◽  
pp. 203-207 ◽  
Author(s):  
Kun Qi Wang ◽  
Guang Qi Ren ◽  
Zhu Feng Shao

A novel measurement system for the dynamic and static light sources is designed in this paper. The method of dynamic gain adjustment measurement is proposed according to the national standards on luminous intensity of dynamic and static light sources. The method is achieved by the way that microcontroller controlled the analog switches to switch automatically in different ranges and adjust the gain automatically depend on the light intensity. By designing the overall structure of the system and using the dynamic gain adjustment method, the range of dynamic measuring illumination can be from 0.001 up to 2000 . The illumination measurement to static light source and the dynamic light source in the peak luminous intensity are achieved via the combination of interval control and dynamic gain adjustment.


Sign in / Sign up

Export Citation Format

Share Document