Effects of thermal regulation structures on the photon sensitivity and spatial resolution of a 1 mm3 resolution breast-dedicated PET system

Author(s):  
Virginia Ch. Spanoudaki ◽  
Arne Vandenbroucke ◽  
Frances W.Y. Lau ◽  
Chen Fang ◽  
Craig S. Levin
1999 ◽  
Vol 38 (04) ◽  
pp. 108-114 ◽  
Author(s):  
H.-J. Kaiser ◽  
U. Cremerius ◽  
O. Sabri ◽  
M. Schreckenberger ◽  
P. Reinartz ◽  
...  

Summary Aim of the present study was to investigate the feasibility of 2-[fluorine-18]-fluoro-2-deoxy-D-glucose (FDG) imaging in oncological patients with a dual head gamma camera modified for coincidence detection (MCD). Methods: Phantom studies were done to determine lesion detection at various lesion-to-background ratios, system sensitivity and spatial resolution. Thirty-two patients with suspected or known malignant disease were first studied with a dedicated full-ring PET system (DPET) applying measured attenuation correction and subsequently with an MCD system without attenuation correction. MCD images were first interpreted without knowledge of the DPET findings. In a second reading, MCD and DPET were evaluated simultaneously. Results: The phantom studies revealed a comparable spatial resolution for DPET and MCD (5.9 × 6.3 × 4.2 mm vs. 5.9 × 6.5 × 6.0 mm). System sensitivity of MCD was less compared to DPET (91 cps/Bq/ml/cmF0V vs. 231 cps/ Bq/ml/cmFOv). At a lesion-to-background ratio of 4:1, DPET depicted a minimal phantom lesion of 1.0 cm in diameter, MCD a minimal lesion of 1.6 cm. With DPET, a total of 91 lesions in 27 patients were classified as malignant. MCD without knowledge of DPET results revealed increased FDG uptake in all patients with positive DPET findings. MCD detected 72 out of 91 DPET lesions (79.1 %). With knowledge of the DPET findings, 11 additional lesions were detected (+12%). MCD missed lesions in six patients with relevance for staging in two patients. All lesions with a diameter above 18 mm were detected. Conclusion: MCD FDG imaging yielded results comparable to dedicated PET in most patients. However, a considerable number of small lesions clearly detectable with DPET were not detected by MCD alone. Therefore, MCD cannot yet replace dedicated PET in all oncological FDG studies. Further technical refinement of this new method is needed to improve image quality (e.g. attenuation correction).


2021 ◽  
Vol 76 (1) ◽  
pp. 56-60
Author(s):  
Adil Bardane ◽  
Jaouad Tajmouati ◽  
Abdelmajid Maghnouj

2016 ◽  
Vol 3 (1) ◽  
pp. 12-26 ◽  
Author(s):  
Malgorzata Z. Pajak ◽  
David Volgyes ◽  
Sally L. Pimlott ◽  
Carlos C. Salvador ◽  
Antonio S. Asensi ◽  
...  

Goals:This paper presents the performance review based on a dual-ring Positron Emission Tomography (PET) scanner being a part of Bruker Albira: a multi-modal small-animal imaging platform. Each ring of Albira PET contains eight detectors arranged as octagon, and each detector is built using a single continuous lutetium-yttrium oxyorthosilicate crystal and multi-anode photo multiplier tube. In two-ring configuration, the scanner covers 94.4 mm in axial- and 80´80 mm in trans-axial direction, which is sufficient to acquire images of small animals (e.g.mice) without the need of moving the animal bed during the scan.Methods:All measurements and majority of data processing were performed according to the NEMA NU4-2008 standard with one exception. Due to the scanner geometry, the spatial resolution test was reconstructed using iterative algorithm instead of the analytical one. The main performance characteristics were compared with those of the other PET sub-systems of tri-modal small-animal scanners.Results:The measured spatial resolution at the centre of the axial field of view in radial, tangential and axial directions was 1.72, 1.70 and 2.45 mm, respectively. The scatter fraction for the mouse-like phantom was 9.8% and for the rat-like phantom, 21.8%. The maximum absolute sensitivity was 5.30%. Finally, the recovery co-efficients for 5, 4, 3, 2, 1 mm diameter rods in image quality phantom were: 0.90, 0.77, 0.66, 0.30 and 0.05, respectively.Conclusion:The Bruker Albira is a versatile small-animal multi-modal device that can be used for variety of studies. Overall the PET sub-system provides a good spatial resolution coupled with better-than average sensitivity and the ability to produce good quality animal images when administering low activities.


Author(s):  
Carsten Hinz ◽  
Siegfried Jahnke ◽  
Ralf Metzner ◽  
Daniel Pflugfelder ◽  
Jurgen Scheins ◽  
...  
Keyword(s):  

Author(s):  
Atsushi Ohtani ◽  
Kazumi Tanaka ◽  
Keishi Kitamura ◽  
Tetsuro Mizuta ◽  
Yoshihiro Inoue ◽  
...  