A novel active power filter for high voltage application

Author(s):  
Ye Zhongming ◽  
B. Dong ◽  
Qian Zhaoming
2018 ◽  
Vol 1 (1) ◽  
pp. 54-66
Author(s):  
Rakan Khalil Antar ◽  
Basil Mohammed Saied ◽  
Rafid Ahmed Khalil

A new control strategy for active power filters is proposed, modeled and implemented in order to improve the power quality of a line commutated converter High voltage DC link. The ability of reactive power and harmonics reductions are generally met by using passive and active power filters. In this paper, modified active power filter with a modified harmonics pulse width modulation algorithm is used to minimize the source harmonics and force the AC supply current to be in the same phase with AC voltage source at both sending and receiving sides of a line commutated converter high voltage DC link. Therefore, it is considered as power factor corrector and harmonics eliminator with random variations in the load current. The modified harmonics pulse width modulation algorithm is applicable for active power filter based on a three-phase five-level and seven-level cascaded H-bridge voltage source inverter. Simulation results show that the suggested modified multilevel active power filters improve total harmonics distortion of both voltage and current with almost unity effective power factor at both AC sides of high voltage DC link. Therefore, modified active power filter is an effective tool for power quality improvement and preferable for line commutated converter high voltage DC link at different load conditions.


2011 ◽  
Vol 201-203 ◽  
pp. 1512-1516
Author(s):  
Jing Jie Peng ◽  
Xiao Ping Fan ◽  
Gang Li

A new hybrid active power filter (NHAPF) and its corresponding controlling method are proposed in the paper, which can be applied in high voltage system. The topology structure of NHAPF is given and its compensating principle is described. The corresponding controlling method is a power direct control, which need not the lower pass filter and improve the performance of detecting precision and velocity. Simulating results show that the feasibility and validity of the compensated system. Harmonic currents and reactive power are compensated well.


2012 ◽  
Vol 433-440 ◽  
pp. 6038-6042
Author(s):  
Li Ping Shi ◽  
Zheng Da Wang ◽  
Ya Jing Hu

Multi-level inverter can output high voltage directly and can be connected without transformer, so it is applied more and more widely in high power situation. This paper presents a cascade H bridge seven-level parallel active power filter. This paper analyzes the principle of cascade H bridge multi-level inverter, designs a cascade H bridge seven-level SAPF based on CPS-SPWM, and the principle and the effect are simulated. The simulation results show that this system can compensate load harmonic current.


Sign in / Sign up

Export Citation Format

Share Document