High-Voltage Overhead Line Breakage Protection Based on Voltage Waveform Correlation

Author(s):  
Zhengfei Lu ◽  
Kefan Zhu ◽  
Fuquan Huang ◽  
Xiaoyu Zhang ◽  
Zijun Liu ◽  
...  
Energies ◽  
2019 ◽  
Vol 12 (6) ◽  
pp. 1004 ◽  
Author(s):  
Carlo Olivieri ◽  
Francesco de Paulis ◽  
Antonio Orlandi ◽  
Giorgio Giannuzzi ◽  
Roberto Salvati ◽  
...  

This work presents the feasibility study of an on-line monitoring technique aimed to discover unwanted variations of longitudinal impedance along the line (also named “impedance discontinuities”) and, possibly, incipient faults typically occurring on high voltage power transmission lines, like those generated by oxidated midspan joints or bolted joints usually present on such lines. In this paper, the focus is placed on the application and proper customization of a technique based on the time-domain reflectometry (TDR) technique when applied to an in-service high-voltage overhead line. An extensive set of numerical simulations are provided in order to highlight the critical points of this particular application scenario, especially those that concern the modeling of both the TDR signal injection strategy and the required high-voltage coupling devices, and to plan a measurement activity. The modeling and simulation approach followed for the study of either the overhead line or the on-line TDR system is fully detailed, discussing three main strategies. Furthermore, some measurement data that were used to characterize the specific coupling device selected for this application at high frequency—that is, a capacitive voltage transformer (CVT)—are presented and discussed too. This work sets the basic concepts underlying the implementation of an on-line remote monitoring system based on reflectometric principles for in-service lines, showing how much impact is introduced by the high-voltage coupling strategy on the amplitude of the detected reflected voltage waves (also named “voltage echoes”).


Author(s):  
Michele Poli ◽  
Antonio Pascucci ◽  
Enrico Maria Carlini ◽  
Giacomo Buora ◽  
Luigi Michi

2013 ◽  
Vol 28 (3) ◽  
pp. 1847-1854
Author(s):  
R. Marusa ◽  
J. Vorsic ◽  
J. Pihler
Keyword(s):  

2002 ◽  
Author(s):  
J. Alzieu ◽  
Y. Le Cunff ◽  
J. Maire ◽  
Y. Moller

Foristek ◽  
2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Martho Pamula ◽  
Sangbua Dinsol Pirade ◽  
Yulius S. Pirade ◽  
Nurhani Amin

Abstract-Overhead line high voltage (SUTT) or commonly called a transmission network or transmission line has very important role in the process of distribution of electrical from power plants to load centers continuously. However, overhead line is one component in the system which is often fault. To avoid damages and greater losses, it has used the distance which is as the primary protection in securing the transmission network or transmission line. In this research, it discussed about one phase-neutral short circuit that happens on line transmission connected to Sidera-Tipo substation by calculating the current fault andoperating time of distance relay using the software of ETAP (electric transientandanalysis program) 12.6.0.  