Phonocardiogram signal analysis using adaptive line enhancer methods on Mixed Signal Processor

Author(s):  
Kausik Basak ◽  
Subhamoy Mandal ◽  
M Manjunatha ◽  
J. Chatterjee ◽  
A. K. Ray
Energies ◽  
2021 ◽  
Vol 14 (12) ◽  
pp. 3532
Author(s):  
Hung-Cheng Chen ◽  
Shin-Shiuan Li ◽  
Shing-Lih Wu ◽  
Chung-Yu Lee

This paper proposes a modular battery management system for an electric motorcycle. The system not only can accurately measure battery voltage, charging current, discharging current, and temperature but also can transmit the data to the mixed-signal processor for battery module monitoring. Moreover, the system can control the battery balancing circuit and battery protection switch to protect the battery module charging and discharging process safety. The modular battery management system is mainly composed of a mixed-signal processor, voltage measurement, current measurement, temperature measurement, battery balancing, and protection switch module. The testing results show that the errors between the voltage value measured by the voltage measurement module and the actual value are less than 0.5%, about 1% under the conditions of different charging and discharging currents of 9 A and 18 A for the current measuring module, less than 1% for the temperature measurement module; and the battery balancing in the battery management system during the charging process. When the module is charged at 4.5 A for about 805 s, each cell of the battery has reached the balancing state. Finally, the testing results validate that the modular battery management system proposed in this paper can effectively manage the battery balancing of each cell in the battery module, battery module overcharge, over-discharge, temperature protection, and control.


2006 ◽  
Vol 41 (7) ◽  
pp. 1638-1647 ◽  
Author(s):  
O. Vermesan ◽  
L.-C.J. Blystad ◽  
R. Bahr ◽  
M. Hjelstuen ◽  
L. Beneteau ◽  
...  

2013 ◽  
Vol 284-287 ◽  
pp. 1627-1632
Author(s):  
Hsieh Chang Huang ◽  
Ching Tang Hsieh ◽  
Guang Lin Hsieh

An ultra-low power, portable, and easily implemented Holter recorder is necessary for patients or researchers of electrocardiogram (ECG). Such a Holter recorder with off-the-shelf components is realized with mixed signal processor (MSP) in this paper. To decrease the complexity of analog circuits and the interference of 60 Hz noise from power line, we use the MSP to implement a finite impulse response (FIR) filter which is equiripple design. We also integrate the ring buffer for the input samples and the symmetrical characteristic of the FIR filter for efficiently computing convolution. The experimental results show that the ECG output signal with the PQRST feature is easy to be distinguished. This ECG signal is recorded for 24 hours using a SD card. Furthermore, the ECG signal is transmitted with a smartphone via Bluetooth to decrease the burden of the Holter recorder. As a result, this paper uses the Lomb method for the spectral analysis of Heart Rate Variability (HRV) better than Fast Fourier Transform (FFT).


1988 ◽  
Vol 10 (2) ◽  
pp. 127-129 ◽  
Author(s):  
C. Murphy ◽  
A. Coats ◽  
J. Conway ◽  
P. Colditz ◽  
P. Rolfe

1973 ◽  
Author(s):  
R. R. Blandford ◽  
T. J. Cohen ◽  
J. W. Woods