Tests on and performance of a high-speed multibreak 138-kV oil circuit breaker

1938 ◽  
Vol 57 (12) ◽  
pp. 696-705 ◽  
Author(s):  
Philip Sporn ◽  
H. P. St. Clair
1938 ◽  
Vol 57 (12) ◽  
pp. 696-704
Author(s):  
Philip Sporn ◽  
H. P. St. Clair

Sensors ◽  
2021 ◽  
Vol 21 (14) ◽  
pp. 4705
Author(s):  
Julian Lich ◽  
Tino Wollmann ◽  
Angelos Filippatos ◽  
Maik Gude ◽  
Juergen Czarske ◽  
...  

Due to their lightweight properties, fiber-reinforced composites are well suited for large and fast rotating structures, such as fan blades in turbomachines. To investigate rotor safety and performance, in situ measurements of the structural dynamic behaviour must be performed during rotating conditions. An approach to measuring spatially resolved vibration responses of a rotating structure with a non-contact, non-rotating sensor is investigated here. The resulting spectra can be assigned to specific locations on the structure and have similar properties to the spectra measured with co-rotating sensors, such as strain gauges. The sampling frequency is increased by performing consecutive measurements with a constant excitation function and varying time delays. The method allows for a paradigm shift to unambiguous identification of natural frequencies and mode shapes with arbitrary rotor shapes and excitation functions without the need for co-rotating sensors. Deflection measurements on a glass fiber-reinforced polymer disk were performed with a diffraction grating-based sensor system at 40 measurement points with an uncertainty below 15 μrad and a commercial triangulation sensor at 200 measurement points at surface speeds up to 300 m/s. A rotation-induced increase of two natural frequencies was measured, and their mode shapes were derived at the corresponding rotational speeds. A strain gauge was used for validation.


Author(s):  
Heshan Fernando ◽  
Vedang Chauhan ◽  
Brian Surgenor

This paper presents the results of a comparative study that investigated the use of image-based and signal-based sensors for fault detection and fault isolation of visually-cued faults on an automated assembly machine. The machine assembles 8 mm circular parts, from a bulk-supply, onto continuously moving carriers at a rate of over 100 assemblies per minute. Common faults on the machine include part jams and ejected parts that occur at different locations on the machine. Two sensor systems are installed on the machine for detecting and isolating these faults: an image-based system consisting of a single camera and a signal-based sensor system consisting of multiple greyscale sensors and limit switches. The requirements and performance of both systems are compared for detecting six faults on the assembly machine. It is found that both methods are able to effectively detect the faults but they differ greatly in terms of cost, ease of implementation, detection time and fault isolation capability. The conventional signal-based sensors are low in cost, simple to implement and require little computing power, but the installation is intrusive to the machine and readings from multiple sensors are required for faster fault detection and isolation. The more sophisticated image-based system requires an expensive, high-resolution, high-speed camera and significantly more processing power to detect the same faults; however, the system is not intrusive to the machine, fault isolation becomes a simpler problem with video data, and the single camera is able to detect multiple faults in its field of view.


Sign in / Sign up

Export Citation Format

Share Document