Voltage regulator modeling for the three-phase power flow in distribution networks

Author(s):  
L.A. Gallego ◽  
A. Padilha-Feltrin
Energies ◽  
2019 ◽  
Vol 13 (1) ◽  
pp. 159 ◽  
Author(s):  
Antonio Rubens Baran Junior ◽  
Thelma S. Piazza Fernandes ◽  
Ricardo Augusto Borba

Active distribution networks must operate properly for different scenarios of load levels and distributed generation. An important operational requirement is to maintain the voltage profile within standard operating limits. To do this, this paper proposed a Multi-Scenario Three-Phase Optimal Power Flow (MTOPF) that plans the voltage regulation of unbalance and active distribution networks considering typical scenarios of operation. This MTOPF finds viable operation points by the optimal adjustments of voltage regulator taps and distribution transformer taps. The differentiating characteristic of this formulation is that in addition to the traditional tuning of voltage regulator taps of an active network applied for just one scenario of load and generation, it also performs the optimal adjustment of distribution transformer taps, which, once fixed, is able to meet the voltage limits of diverse operating situations. The optimization problem was solved by the primal-dual interior-point method and the formulation was tested using the IEEE 123-bus system.


Computation ◽  
2021 ◽  
Vol 9 (7) ◽  
pp. 80
Author(s):  
John Fernando Martínez-Gil ◽  
Nicolas Alejandro Moyano-García ◽  
Oscar Danilo Montoya ◽  
Jorge Alexander Alarcon-Villamil

In this study, a new methodology is proposed to perform optimal selection of conductors in three-phase distribution networks through a discrete version of the metaheuristic method of vortex search. To represent the problem, a single-objective mathematical model with a mixed-integer nonlinear programming (MINLP) structure is used. As an objective function, minimization of the investment costs in conductors together with the technical losses of the network for a study period of one year is considered. Additionally, the model will be implemented in balanced and unbalanced test systems and with variations in the connection of their loads, i.e., Δ− and Y−connections. To evaluate the costs of the energy losses, a classical backward/forward three-phase power-flow method is implemented. Two test systems used in the specialized literature were employed, which comprise 8 and 27 nodes with radial structures in medium voltage levels. All computational implementations were developed in the MATLAB programming environment, and all results were evaluated in DigSILENT software to verify the effectiveness and the proposed three-phase unbalanced power-flow method. Comparative analyses with classical and Chu & Beasley genetic algorithms, tabu search algorithm, and exact MINLP approaches demonstrate the efficiency of the proposed optimization approach regarding the final value of the objective function.


Computation ◽  
2021 ◽  
Vol 9 (6) ◽  
pp. 61
Author(s):  
Oscar Danilo Montoya ◽  
Juan S. Giraldo ◽  
Luis Fernando Grisales-Noreña ◽  
Harold R. Chamorro ◽  
Lazaro Alvarado-Barrios

The power flow problem in three-phase unbalanced distribution networks is addressed in this research using a derivative-free numerical method based on the upper-triangular matrix. The upper-triangular matrix is obtained from the topological connection among nodes of the network (i.e., through a graph-based method). The main advantage of the proposed three-phase power flow method is the possibility of working with single-, two-, and three-phase loads, including Δ- and Y-connections. The Banach fixed-point theorem for loads with Y-connection helps ensure the convergence of the upper-triangular power flow method based an impedance-like equivalent matrix. Numerical results in three-phase systems with 8, 25, and 37 nodes demonstrate the effectiveness and computational efficiency of the proposed three-phase power flow formulation compared to the classical three-phase backward/forward method and the implementation of the power flow problem in the DigSILENT software. Comparisons with the backward/forward method demonstrate that the proposed approach is 47.01%, 47.98%, and 36.96% faster in terms of processing times by employing the same number of iterations as when evaluated in the 8-, 25-, and 37-bus systems, respectively. An application of the Chu-Beasley genetic algorithm using a leader–follower optimization approach is applied to the phase-balancing problem utilizing the proposed power flow in the follower stage. Numerical results present optimal solutions with processing times lower than 5 s, which confirms its applicability in large-scale optimization problems employing embedding master–slave optimization structures.


Sign in / Sign up

Export Citation Format

Share Document