Elimination of multiple estimation for single phase fault location in power distribution systems considering the load current

Author(s):  
J. Ramirez-Ramirez ◽  
J. Arrieta-Giraldo ◽  
J. Mora-Florez
Author(s):  
Wen Fan ◽  
Yuan Liao ◽  
Ning kang

AbstractAccurate fault location in distribution systems greatly shortens maintenance time and improves reliability. This paper presents novel methods to pinpoint fault location and identify possible bad measurements for enhanced accuracy. It is assumed that network parameters and topology of the distribution network are available. The methods are applicable to a single fault as well as simultaneous faults and are applicable to both balanced and unbalanced networks. The methods utilize synchronized voltage and current phasor measurements to locate the fault. The methods are validated by simulation studies using the modified IEEE 34-Node Test System. Case studies have demonstrated that the methods are suitable for distribution systems with high penetration of distributed generations.


DYNA ◽  
2015 ◽  
Vol 82 (192) ◽  
pp. 141-149 ◽  
Author(s):  
Andres Felipe Panesso-Hernández ◽  
Juan Mora-Flórez ◽  
Sandra Pérez-Londoño

<p>The impedance-based approaches for fault location in power distribution systems determine a faulted line section. Next, these require of the estimation of the voltages and currents at one or both section line ends to exactly determine the fault location. It is a challenge because in most of the power distribution systems, measurements are only available at the main substation.  This document presents a modeling proposal of the power distribution system and an easy implementation method to estimate the voltages and currents at the faulted line section, using the measurements at the main substation, the line, load, transformer parameters and other serial and shunt connected devices and the power system topology. The approach here proposed is tested using a fault locator based on superimposed components, where the distance estimation error is lower than 1.5% in all of the cases. </p>


2013 ◽  
Vol 860-863 ◽  
pp. 2007-2012 ◽  
Author(s):  
Xiao Meng ◽  
Neng Ling Tai ◽  
Yan Hu ◽  
Xia Yang

The failure current in resonant grounder power distribution system is small, so it is difficult to detect the fault feeder. This passage presents the equivalent circuit of resonant grounded system, and discusses the difference of electrical characteristics between faulty feeder and sound feeders by using shunt resistors. To reduce the influence of shunt resistors on the system and improve the detection sensitivity, it presents the method of shunting multi-level resistors, and it proves the sensitivity and reliability of this method by EMTP simulation.