Dynamic performance enhancement of voltage source inverter by constant-frequency hysteretic current controller

Author(s):  
Pradeep Kumar Sahu ◽  
Somnath Maity
Author(s):  
A R Haider Mohomad ◽  
Saleh A Saleh ◽  
Riming Shao ◽  
Liuchen Chang ◽  
Shuang Xu

2014 ◽  
Vol 15 (1) ◽  
pp. 13-23 ◽  
Author(s):  
D. Kalyanraj ◽  
S. Lenin Prakash

Abstract A constant frequency hysteresis current control technique for a three-phase voltage source inverter (VSI) has been developed for AC drives, power quality and renewable energy applications. This paper presents a digital implementation of a constant frequency hysteresis current control technique for a three-phase VSI feeding an inductive load, using digital signal controller TMS320F2812. The limitations of variable frequency hysteresis control have been discussed and overcoming these limitations by means of digital implementation has been proposed. The complete design procedure of the proposed technique has been presented with an illustrative example. The three-phase VSI feeding an inductive load has also been simulated by using MATLAB and the simulation results have been presented. The hardware results of hysteresis current controlled three-phase VSI feeding an inductive load have been presented. Also the performance analysis of the hysteresis current controller has been presented. Operation of this controller has also been explained with a help of phase plane trajectory of hysteresis controller.