scholarly journals Uncertainty and Disturbance Estimator-Based Controller Equipped With a Time-Delayed Filter to Improve the Voltage Quality of Inverters

2019 ◽  
Vol 66 (1) ◽  
pp. 459-469 ◽  
Author(s):  
Shlomo Y. Gadelovits ◽  
Qing-Chang Zhong ◽  
Visakan Kadirkamanathan ◽  
Alon Kuperman
2019 ◽  
Vol 66 (11) ◽  
pp. 8947-8957 ◽  
Author(s):  
Shlomo Y. Gadelovits ◽  
Dauren Insepov ◽  
Visakan Kadirkamanathan ◽  
Qing-Chang Zhong ◽  
Alon Kuperman

2004 ◽  
Vol 126 (4) ◽  
pp. 905-910 ◽  
Author(s):  
Qing-Chang Zhong ◽  
David Rees

This paper proposes a robust control strategy for uncertain LTI systems. The strategy is based on an uncertainty and disturbance estimator (UDE). It brings similar performance as the time-delay control (TDC). The advantages over TDC are: (i) no delay is introduced into the system; (ii) there are no oscillations in the control signal; and (iii) there is no need of measuring the derivatives of the state vector. The robust stability of LTI-SISO systems is analyzed, and simulations are given to show the effectiveness of the UDE-based control with a comparison made with TDC.


2020 ◽  
Vol 22 (1-2) ◽  
pp. 137-144
Author(s):  
Hidajet Salkić ◽  
Amir Softić ◽  
Amer Salkić

The electric power system, as an integrated system for transmission, distribution and consumption of electricity, is one of the most complex technical and economic systems today. Customers affect on the voltage quality of power network, but the network also has an impact on customers. All disturbances in the network can disrupt operation of the network and affect on operation of the customers, as well as reduce the level of efficiency and operation life or even seriously damage network. Number of customers is increasing every day, as well as proportion of customers who generate disturbances in the network and, at the same time, are sensitive to them. These circumstances impose the need for frequent monitoring of the network, so the analysis of power quality is not unjustified cost but extremely important and profitable investment. The quality of electricity, as part of the overall quality supply of electricity customers in deregulated conditions of liberal electricity market becomes significant regulatory parameter for network operators and a significant contracting parameter on the electricity market. Network operators are obliged to establish a system of individual measurements and a system of permanent monitoring of power quality parameters to determine the state and improve the parameters to the standardized level. Technical parameters are determined by the recommendations made at the international level and may, but do not need, be legally binding. Maintaining a certain level of voltage quality at some point of the network is the responsibility of electricity distributor. This task distributor executes by limiting of negative effects of producer/customer to the network. Therefore, each electricity producer/customer is obliged to reduce own negative feedback effects (injection of higher harmonics, taking of reactive power, emissions of flickers and loads unbalances) to a prescribed, prearranged, limited values. There are many norms that describe the quality of electricity, but in Europe the best known is EN50160 (issued by CENLEC). This paper presents the approach to measuring the voltage quality at the point of electricity delivery from distributed source into distribution network from the aspect of limiting the negative feedback of distributed source on the voltage quality.


Author(s):  
Hayder Ali Mohamed ◽  
Hanan Mikhael D. Habbi

<p><span>This paper presents the minimization of the total harmonic distortion (THD) of the current signal for open-end winding induction motor by using dual two-level inverter. In order to obtain a good value of THD, the space vector PWM has been used for switching the dual two-level inverter to improve the output voltage quality, gets a low common mode voltage, reduce the execution time, and to save the memory capacity. The proposed scheme uses two different DC voltage source with two two level inverter in order of minimizing the number of components. As well as it is an important to utilize the energy which increases the application of dual inverter in microgrids. All simulation results are obtained using Matlab/Simulink. </span></p>


Sign in / Sign up

Export Citation Format

Share Document