Application of Unscented Transform for Efficient Calculation of Statistics for Electromagnetic Transients

Author(s):  
Oscar Lennerhag ◽  
Math H.J. Bollen
2007 ◽  
Vol 11 (2) ◽  
pp. 1-43 ◽  
Author(s):  
Michael Kalkbrener ◽  
Anna Kennedy ◽  
Monika Popp

2020 ◽  
Vol 56 (2) ◽  
pp. 80-82 ◽  
Author(s):  
Xinlei Chen ◽  
Xiuqiang Liu ◽  
Changqing Gu

Author(s):  
Hongbo Zou ◽  
Juan Tao ◽  
Salah K. Elsayed ◽  
Ehab E. Elattar ◽  
Abdulaziz Almalaq ◽  
...  

Energies ◽  
2021 ◽  
Vol 14 (7) ◽  
pp. 1943
Author(s):  
Bader N. Alajmi ◽  
Mostafa I. Marei ◽  
Ibrahim Abdelsalam ◽  
Mohamed F. AlHajri

A high-frequency multi-port (HFMP) direct current (DC) to DC converter is presented. The proposed HFMP is utilized to interface a photovoltaic (PV) system. The presented HFMP is compact and can perform maximum power point tracking. It consists of a high-frequency transformer with many identical input windings and one output winding. Each input winding is connected to a PV module through an H-bridge inverter, and the maximum PV power is tracked using the perturb and observe (P&O) technique. The output winding is connected to a DC bus through a rectifier. The detailed analysis and operation of the proposed HFMP DC-DC converter are presented. Extensive numerical simulations are conducted, using power system computer aided design (PSCAD)/electromagnetic transients including DC (EMTDC) software, to evaluate the operation and dynamic behavior of the proposed PV interfacing scheme. In addition, an experimental setup is built to verify the performance of the HFMP DC-DC converter.


Energies ◽  
2021 ◽  
Vol 14 (2) ◽  
pp. 474
Author(s):  
Junxi Wang ◽  
Qi Jia ◽  
Gangui Yan ◽  
Kan Liu ◽  
Dan Wang

With the development of large-scale new energy, the wind–thermal bundled system transmitted via high-voltage direct current (HVDC) has become the main method to solve the problem of wind power consumption. At the same time, the problem of subsynchronous oscillation among wind power generators, high-voltage direct current (HVDC), and synchronous generators (SGs) has become increasingly prominent. According to the dynamic interaction among doubly fed induction generators (DFIGs), HVDC, and SGs, a linearization model of DFIGs and SGs transmitted via HVDC is established, and the influence of the electromagnetic transient of wind turbines and HVDC on the electromechanical transient processes of SGs is studied. Using the method of additional excitation signal injection, the influence of the main factors of DFIG on the damping characteristics of each torsional mode of SG is analyzed, including control parameters and operation conditions when the capacity of HVDC is fixed. The mechanism of the negative damping torsional of SGs is identified. A time-domain simulation model is built in Electromagnetic Transients including DC/Power Systems Computer Aided Design (EMTDC/PSCAD) to verify the correctness and effectiveness of the theoretical analysis.


Sign in / Sign up

Export Citation Format

Share Document