Validation of a new panel of automated chemiluminescence assays for von Willebrand factor antigen and activity in the screening for von Willebrand disease

2013 ◽  
Vol 35 (5) ◽  
pp. 555-565 ◽  
Author(s):  
C. J. Verfaillie ◽  
E. De Witte ◽  
K. M. J. Devreese
Blood ◽  
1986 ◽  
Vol 68 (1) ◽  
pp. 269-274 ◽  
Author(s):  
PM Mannucci ◽  
R Lombardi ◽  
AB Federici ◽  
JA Dent ◽  
TS Zimmerman ◽  
...  

Abstract A patient with a lifelong bleeding disorder was diagnosed as having Type II von Willebrand disease. The larger multimers of von Willebrand factor were absent from her plasma but present in platelets. A high- resolution electrophoretic technique was used to study the complex structure of individual von Willebrand factor multimers. In normal plasma, each multimer could be resolved into five bands: a more intense central one and four less intense, two moving faster and two slower than the central band. In normal platelets, each multimer could also be resolved into five bands. The central one had a mobility similar to that in plasma, whereas the four satellite bands had a mobility that differed from that of the corresponding plasma bands. In the patient, platelet von Willebrand factor antigen content and ristocetin cofactor activity were normal, and von Willebrand factor showed the same structure of individual multimers as seen in normal platelets. On the other hand, plasma von Willebrand factor antigen and ristocetin cofactor activity were decreased, and the structure of individual von Willebrand factor multimers was different from that of normal plasma and similar to that seen in normal and patient's platelets. After infusion of 1-deamino-8-D-arginine vasopressin, the largest von Willebrand factor multimers, as well as new satellite bands with a mobility similar to those in normal plasma, appeared in the patient plasma, and the levels of von Willebrand factor antigen and ristocetin cofactor activity became normal. Yet no relevant change in the prolonged bleeding time was observed. This new variant of von Willebrand disease, therefore, is characterized by the presence of a dysfunctional von Willebrand factor molecule that exhibits unique structural abnormalities in plasma but appears to be normal in platelets. The designation of Type IIF is proposed for this type of von Willebrand disease in accordance with the terminology that has been previously used.


Blood ◽  
1987 ◽  
Vol 69 (5) ◽  
pp. 1419-1420
Author(s):  
A Asakura ◽  
J Harrison ◽  
E Gomperts ◽  
C Abildgaard

Type IIA von Willebrand's Disease (vWD) is the most common type II variant, and all reported cases (56 individuals in 26 families) have had autosomal dominant inheritance. An eight-year-old female with an increased bleeding tendency since infancy was found to have laboratory values typical of type IIA vWD, but her parents and siblings were asymptomatic. With the exception of uniformly decreased levels of ristocetin cofactor in relation to von Willebrand factor antigen, the results of family studies were normal including the presence of large multimeric forms of von Willebrand factor antigen. These findings are consistent with the propositus having the homozygous state of an autosomal recessive trait. Desmopressin infusion in the propositus was followed by a significant increase of factor VIII coagulant and von Willebrand factor antigen but a limited change in ristocetin cofactor with no development of large multimers.


2019 ◽  
Vol 94 (12) ◽  
pp. 1425-1432 ◽  
Author(s):  
Penelope Motum ◽  
Sarah Just ◽  
Diane Zebeljan ◽  
Catherine Nicholls ◽  
Geoffrey Kershaw ◽  
...  

Blood ◽  
1986 ◽  
Vol 68 (1) ◽  
pp. 269-274
Author(s):  
PM Mannucci ◽  
R Lombardi ◽  
AB Federici ◽  
JA Dent ◽  
TS Zimmerman ◽  
...  

A patient with a lifelong bleeding disorder was diagnosed as having Type II von Willebrand disease. The larger multimers of von Willebrand factor were absent from her plasma but present in platelets. A high- resolution electrophoretic technique was used to study the complex structure of individual von Willebrand factor multimers. In normal plasma, each multimer could be resolved into five bands: a more intense central one and four less intense, two moving faster and two slower than the central band. In normal platelets, each multimer could also be resolved into five bands. The central one had a mobility similar to that in plasma, whereas the four satellite bands had a mobility that differed from that of the corresponding plasma bands. In the patient, platelet von Willebrand factor antigen content and ristocetin cofactor activity were normal, and von Willebrand factor showed the same structure of individual multimers as seen in normal platelets. On the other hand, plasma von Willebrand factor antigen and ristocetin cofactor activity were decreased, and the structure of individual von Willebrand factor multimers was different from that of normal plasma and similar to that seen in normal and patient's platelets. After infusion of 1-deamino-8-D-arginine vasopressin, the largest von Willebrand factor multimers, as well as new satellite bands with a mobility similar to those in normal plasma, appeared in the patient plasma, and the levels of von Willebrand factor antigen and ristocetin cofactor activity became normal. Yet no relevant change in the prolonged bleeding time was observed. This new variant of von Willebrand disease, therefore, is characterized by the presence of a dysfunctional von Willebrand factor molecule that exhibits unique structural abnormalities in plasma but appears to be normal in platelets. The designation of Type IIF is proposed for this type of von Willebrand disease in accordance with the terminology that has been previously used.


Blood ◽  
1987 ◽  
Vol 69 (5) ◽  
pp. 1419-1420 ◽  
Author(s):  
A Asakura ◽  
J Harrison ◽  
E Gomperts ◽  
C Abildgaard

Abstract Type IIA von Willebrand's Disease (vWD) is the most common type II variant, and all reported cases (56 individuals in 26 families) have had autosomal dominant inheritance. An eight-year-old female with an increased bleeding tendency since infancy was found to have laboratory values typical of type IIA vWD, but her parents and siblings were asymptomatic. With the exception of uniformly decreased levels of ristocetin cofactor in relation to von Willebrand factor antigen, the results of family studies were normal including the presence of large multimeric forms of von Willebrand factor antigen. These findings are consistent with the propositus having the homozygous state of an autosomal recessive trait. Desmopressin infusion in the propositus was followed by a significant increase of factor VIII coagulant and von Willebrand factor antigen but a limited change in ristocetin cofactor with no development of large multimers.


Sign in / Sign up

Export Citation Format

Share Document