Impact of left common pulmonary veins in the contact force versus cryoballoon atrial fibrillation ablation (CIRCA‐DOSE) study

2020 ◽  
Vol 31 (9) ◽  
pp. 2300-2307
Author(s):  
Jacob M. Larsen ◽  
Marc W. Deyell ◽  
Laurent Macle ◽  
Jean Champagne ◽  
Jean‐Francois Sarrazin ◽  
...  
Heart Rhythm ◽  
2020 ◽  
Vol 17 (6) ◽  
pp. 897-904
Author(s):  
Jason G. Andrade ◽  
Marc W. Deyell ◽  
Stanley Nattel ◽  
Paul Khairy ◽  
Marc Dubuc ◽  
...  

2020 ◽  
Vol 2 (1) ◽  
pp. e000058
Author(s):  
Joseph G Akar ◽  
James P Hummel ◽  
Xiaoxi Yao ◽  
Lindsey Sangaralingham ◽  
Sanket Dhruva ◽  
...  

ObjectivesContact force-sensing catheters allow real-time catheter-tissue contact force monitoring during atrial fibrillation. These catheters were rapidly adopted into clinical practice following market introduction in 2014, but concerns have been raised regarding collateral damage such as esophageal injury. We sought to examine whether the introduction of force-sensing catheters was associated with a change in short-term and intermediate-term acute care use, complications and mortality following atrial fibrillation ablation.DesignRetrospective cohort analysis. We used inverse probability treatment weight matching to account for the differences in baseline characteristics between groups.SettingWe examined patients included in the OptumLabs Data Warehouse who underwent ablation for atrial fibrillation before (2011–2013) and after (2015–2017) the market introduction of contact force-sensing catheters.Main outcome measuresWe examined 30-day and 90-day rates of all-cause acute care use, including hospitalizations and emergency department visits, as well as death and hospitalization for catheter-related complications, including atrioesophageal fistula, pericarditis, cardiac tamponade/perforation and stroke/transient ischemic attack.ResultsOur sample included 3470 and 5772 patients who underwent atrial fibrillation (AF) ablation before and after market introduction of contact force-sensing catheters, respectively. Complication rates were low and did not differ between the two periods (p>0.10 for each outcome). The 30-day and 90-day mortality was 0.1% and 0.3%, respectively after market introduction and unchanged from prior to 2014. The 90-day rates of all-cause acute care use decreased, from 27.0% in 2011–2013 to 23.9% in 2015–2017 (p<0.001).ConclusionsAF ablation-related catheter complications and mortality are low and there has been no significant change following the introduction of force-sensing catheters.


Author(s):  
Mohammed Shurrab ◽  
Luigi Di Biase ◽  
David F. Briceno ◽  
Anna Kaoutskaia ◽  
Saleem Haj‐Yahia ◽  
...  

2016 ◽  
Vol 2016 ◽  
pp. 1-4
Author(s):  
John J. Lee ◽  
Denis Weinberg ◽  
Rishi Anand

Pulmonary vein stenosis is a well-established possible complication following an atrial fibrillation ablation of pulmonary veins. Symptoms of pulmonary vein stenosis range from asymptomatic to severe exertional dyspnea. The number of asymptomatic patients with pulmonary vein stenosis is greater than originally estimated; moreover, only about 22% of severe pulmonary vein stenosis requires intervention. We present a patient with severe postatrial fibrillation (AF) ablation pulmonary vein (PV) stenosis, which was seen on multiple imaging modalities including cardiac computed tomography (CT) angiogram, lung perfusion scan, and pulmonary angiogram. This patient did not have any pulmonary symptoms. Hemodynamic changes within a stenosed pulmonary vein might not reflect the clinical severity of the obstruction if redistribution of pulmonary artery flow occurs. Our patient had an abnormal lung perfusion and ventilation (V/Q) scan, suggesting pulmonary artery blood flow redistribution. The patient ultimately underwent safe repeat atrial fibrillation ablation with successful elimination of arrhythmia.


2019 ◽  
Vol 2 (51) ◽  
pp. 4-7
Author(s):  
Agnieszka Wojdyła-Hordyńska ◽  
Jakub Baran ◽  
Paweł Derejko

The first use of cryoablation in the treatment of arrhythmia has already been described over 40 years ago [1]. Since the introduction of cryoballoon in pulmonary veins isolation in atrial fibrillation treatment, the method has started to attract a lot of interest. Over 350,000 procedures around the word were carried out only by 2018 [2]. Recently, there have been several new publications on the results of second-generation cryoballoon ablation [2, 3, 4]. In view of technology changes, and to summarize years of experience in the treatment of atrial fibrillation, the first Cryousers conference was organized, and held in 2018 in Poland. During this meeting a survey was conducted, obtaining data on the practice of atrial fibrillation treatment in 38 Polish electrophysiological centers performing cryoablation of atrial fibrillation using both balloons, Arctic Front Advance, Medtronic Inc., Minneapolis MN, and radiofrequency point by point ablation. Around 3,745 cryoballoon procedures were performed in the surveyed centers during the year preceding the survey. The survey concerned practical issues related to the qualification and preparation of patients for the procedure, its course, and the results of pulmonary veins isolation in Poland.


2021 ◽  
Author(s):  
Sara Rita Vacirca

Objective: Intraoperative CARTO Mapping for Atrial Fibrillation ablation in cardiac surgery. Background: Surgical ablation of Atrial Fibrillation is usually performed without mapping. The study aims to determine if intraoperative CARTO can be useful to guide the ablating procedure. Methods and Findings: Fourteen patients with symptomatic and drug-refractory concomitant AF were operated on in 2003 and 2004. CARTO mapping was performed before and after surgical bipolar radio-frequency ablation. Application of energy was repeated when residual electrical activity was detected at the pulmonary veins-atrial junction. Pacing wires were applied on right and left pulmonary veins distally to the ablation line to confirm the exit block. The mapping protocol was completed in 12 patients. Acute left atrium-pulmonary vein isolation was achieved after single or double energy application in 2/12 (16.6%) and 9/12 (75%) patients, respectively. The mean duration of the mapping and ablation procedure was 67 minutes. At discharge, PV isolation persisted in 10 patients: exit block was confirmed by the absence of pacing through the pulmonary veins electrodes. After a mean follows up of 181 months, no further recurrent AF events were registered in 9/12 (69.2%) patients. Conclusions: CARTO system is useful during open-heart surgery to guide the ablating strategy.


Sign in / Sign up

Export Citation Format

Share Document