Accounting for Out-of-Bandwidth Modes in the Assumed Modes Approach: Implications on Colocated Output Feedback Control

1997 ◽  
Vol 119 (3) ◽  
pp. 390-395 ◽  
Author(s):  
R. L. Clark

Colocated, output feedback is commonly used in the control of reverberant systems. More often than not, the system to be controlled displays high modal density at a moderate frequency, and thus the compliance of the out-of-bandwidth modes significantly influences the performance of the closed-loop system at low frequencies. In the assumed modes approach, the inclusion principle is used to demonstrate that the poles of the dynamic system converge from above when additional admissible functions are used to expand the solution. However, one can also interpret the convergence of the poles in terms of the zeros of the open-loop system. Since colocated inputs and outputs are known to have interlaced poles and zeros, the effect of a modification to the structural impedance locally serves to couple the modes of the system through feedback. The poles of the modified system follow loci defined by the relative location of the open-loop poles and zeros. Thus, as the number of admissible functions used in the series expansion is increased, the interlaced zeros of the colocated plant tend toward the open-loop poles, causing the closed-loop poles to converge from above as predicted by the inclusion principle. The analysis and results presented in this work indicate that the cumulative compliance of the out-of-bandwidth modes and not the modes themselves is required to converge the zeros of the open-loop system and the poles of the closed-loop system.

Author(s):  
Mounir Hammouche ◽  
Philippe Lutz ◽  
Micky Rakotondrabe

The problem of robust and optimal output feedback design for interval state-space systems is addressed in this paper. Indeed, an algorithm based on set inversion via interval analysis (SIVIA) combined with interval eigenvalues computation and eigenvalues clustering techniques is proposed to seek for a set of robust gains. This recursive SIVIA-based algorithm allows to approximate with subpaving the set solutions [K] that satisfy the inclusion of the eigenvalues of the closed-loop system in a desired region in the complex plane. Moreover, the LQ tracker design is employed to find from the set solutions [K] the optimal solution that minimizes the inputs/outputs energy and ensures the best behaviors of the closed-loop system. Finally, the effectiveness of the algorithm is illustrated by a real experimentation on a piezoelectric tube actuator.


Volume 3 ◽  
2004 ◽  
Author(s):  
Robert A. Leishear ◽  
Jeffrey H. Morehouse

The effects of fluid transients, or water hammer, in closed loop systems are somewhat different than those observed in open ended systems. The open loop system has received much attention in the literature, not so for the closed system. The generally accepted method of characteristics (MOC) technique was applied herein to investigate closed loop systems. The magnitudes of the pressures during fluid transients were investigated for examples of rapid valve closures, and the operations of parallel pumps. The effects of trapped air in the system were also considered for these examples. To reduce the pressures caused by the transients, the installation of slow closing valves were evaluated for different conditions.


Author(s):  
Mohammad Rastgaar Aagaah ◽  
Mehdi Ahmadian ◽  
Steve C. Southward

A novel Eigenstructure Assignment (ESA) method for vibration confinement of flexible structures has been developed. This method is an output feedback control and determines the closed-loop systems that their eigenvectors are orthogonalized to the open-loop eigenvectors. This method is a numerical method and used Singular Value Decomposition (SVD) to find the null space of the closed-loop eigenvectors. The matrix that spans the null space can be used to regenerate the open-loop system as well as the systems that have orthogonal eigenvectors to the regenerated open-loop system. As a result the isolation of vibration is independent of the type of the disturbance. Also in this method, the energy of the closed-loop system is minimized. As an important outcome, the proposed method needs neither to specify the closed-loop eigenvalues nor to define a desired set of eigenvectors.


2012 ◽  
Vol 442 ◽  
pp. 315-320
Author(s):  
Yun Fang Feng

A design method of fractional controller has been developed to meet the five different specifications, including for the closed-loop system robustness. The specifications of cross frequency, phase to get financing ϕ meters and robustness and complete performance curve based on level off the stage of open loop system, ensure damping is worse reaction time of model uncertainty gain change.


Author(s):  
N. Loix ◽  
A. Preumont

Abstract This paper aims to attract the attention of the designers of active structures on the importance of evaluating properly the feedthrough component of the open-loop transfer functions. It is shown that overlooking the feedthrough component can change significantly the location of the zeros of the open-loop system and, as a result, alter drastically the performance of the closed-loop system. The feedthrough term may result from the quasi-static contribution of the high frequency modes or from local effects that are neglected by over-simplified modelling techniques (e.g. plate or beam instead of shell). The problem is illustrated with a cantilever beam provided with strain actuators.


1986 ◽  
Vol 120 (1) ◽  
pp. 369-385 ◽  
Author(s):  
G. WEILAND ◽  
U. BÄSSLER ◽  
M. BRUNNER

An experimental arrangement was constructed which is based on the open-loop femur-tibia control system of two stick insect species (Carausius morosus and Cuniculina impigra). It could be artificially closed in the following way: the position of the tibia was measured by an optical device and this value was used to drive a penmotor which moved the receptor apodeme of the femoral chordotonal organ in the same way as in intact animals. This arrangement allows direct comparison of the behaviour of the open-loop and the closed-loop system as well as introducing an additional delay. The Carausius system has a phase reserve of only 30°-50° and the factor of feedback control approaches 1 between 1 and 2 Hz. This agrees with the observation that an additional delay of 70–200 ms produces long-lasting oscillations of 1–2 Hz. The Cuniculina system has a larger phase reserve and consequently a delay of 200 ms produced no oscillations. All experiments show that extrapolation from the open-loop system to the closed-loop system is valid, despite the non-linear characteristics of the loop. Consequences for servo-mechanisms during walking and rocking movements are discussed.


Author(s):  
Shuichi Fukuda

This paper points out that in order to provide emotional satisfaction to the customer, hardware products should be modularized not only with functions or shapes, but with more meanings such as adaptability, etc. Thus, a network-structured modularization is called for more than a tree-structured one to cope with diverse customer expectations. The emerging field of material digitalization, which can be compared to physical FEM, is expected to provide a versatile and flexible tool for this purpose and it will change our design from the current open loop system to the closed loop system so that it will provide us with the capability of managing deterioration and that of adaptability to the frequently and widely changing situations.


2014 ◽  
Vol 536-537 ◽  
pp. 1170-1173
Author(s):  
Hong Yang ◽  
Huan Huan Lü ◽  
Le Zhang

The output feedback control problem is addressed for a class of switched fuzzy Systems. Using multiple Lyapunov function method and switching law, the relevant closed-loop system is asymptotically stable, with the switching law designed to implement the global asymptotic stability. The sufficient conditions to ensure the output feedback asymptotically stable output feedback control of closed-loop system are studied. The sufficient condition is transformed into Linear Matrix Inequality (LMI) problem which are more solvable. Finally, a numerical simulation example is employed to illustrate the effectiveness and the convergence of the design methodologies.


Author(s):  
Amit Pandey ◽  
Maurício de Oliveira ◽  
Chad M. Holcomb

Several techniques have recently been proposed to identify open-loop system models from input-output data obtained while the plant is operating under closed-loop control. So called multi-stage identification techniques are particularly useful in industrial applications where obtaining input-output information in the absence of closed-loop control is often difficult. These open-loop system models can then be employed in the design of more sophisticated closed-loop controllers. This paper introduces a methodology to identify linear open-loop models of gas turbine engines using a multi-stage identification procedure. The procedure utilizes closed-loop data to identify a closed-loop sensitivity function in the first stage and extracts the open-loop plant model in the second stage. The closed-loop data can be obtained by any sufficiently informative experiment from a plant in operation or simulation. We present simulation results here. This is the logical process to follow since using experimentation is often prohibitively expensive and unpractical. Both identification stages use standard open-loop identification techniques. We then propose a series of techniques to validate the accuracy of the identified models against first principles simulations in both the time and frequency domains. Finally, the potential to use these models for control design is discussed.


Sign in / Sign up

Export Citation Format

Share Document