Waste Heat Disposal to Air with Mechanical and Natural Draft—Some Analytical Design Considerations

1980 ◽  
Vol 102 (3) ◽  
pp. 719-727
Author(s):  
Ali Montakhab

There is a growing acceptance of the future necessity of dry and wet/dry cooling tower systems for large power stations in spite of their economic penalty compared with once-through cooling, cooling ponds, and evaporative cooling towers. If technological improvements succeed in reducing the current costs of dry cooling towers, their future applications will be accelerated. The main objective of this work is to quantify the factors that reduce the overall size and cost of the tower and the associated heat transfer system and to provide a basis for establishing the conditions that result in dry cooling tower cost reductions. As a first-step, the design equations for forced-and natural-draft dry cooling towers are derived in close form to give explicit relations for salient design variables. Subsequently, these equations are used to establish a set of influence coefficients for quantifying the effects of various key design variables on the design of forced- and natural-draft cooling towers.

Author(s):  
A. Montakhab

Because of its relatively high coolant temperature, the closed cycle gas turbine HTGR is well adapted to dry cooling and its waste heat can be rejected with relatively low cost. The preliminary design of natural-draft dry cooling towers for a 1200 MW(e) GT-HTGR is presented. The effects of air approach velocity, capacity rates of air and water mediums, and number of heat exchanger cross flow passes on salient tower and heat exchanger dimensions are studied. Optimum tower designs are achieved with three cross flow passes for the heat exchanger, resulting in a simultaneous minimization of tower height, heat exchanger surface area and circulating water pumping power. Four alternative tower designs are considered and their relative merits are compared. It is concluded that the 1200 MW(e) plant can be cooled by a single tower design which is well within the present state of the natural-draft dry cooling tower technology. In comparison, the fossil-fired or HTGR steam plants of the same output is shown to need three such towers.


2021 ◽  
Vol 188 ◽  
pp. 116628 ◽  
Author(s):  
Yuchen Dai ◽  
Yuanshen Lu ◽  
Alexander Y. Klimenko ◽  
Ying Wang ◽  
Kamel Hooman

Author(s):  
Shuo Li ◽  
M. R. Flynn

AbstractVisible plumes above wet cooling towers are of great concern due to the associated aesthetic and environmental impacts. The parallel path wet/dry cooling tower is one of the most commonly used approaches for plume abatement, however, the associated capital cost is usually high due to the addition of the dry coils. Recently, passive technologies, which make use of free solar energy or the latent heat of the hot, moist air rising through the cooling tower fill, have been proposed to minimize or abate the visible plume and/or conserve water. In this review, we contrast established versus novel technologies and give a perspective on the relative merits and demerits of each. Of course, no assessment of the severity of a visible plume can be made without first understanding its atmospheric trajectory. To this end, numerous attempts, being either theoretical or numerical or experimental, have been proposed to predict plume behavior in atmospheres that are either uniform versus density-stratified or still versus windy (whether highly-turbulent or not). Problems of particular interests are plume rise/deflection, condensation and drift deposition, the latter consideration being a concern of public health due to the possible transport and spread of Legionella bacteria.


2017 ◽  
Vol 112 ◽  
pp. 326-339 ◽  
Author(s):  
Huan Ma ◽  
Fengqi Si ◽  
Yu Kong ◽  
Kangping Zhu ◽  
Wensheng Yan

2018 ◽  
Vol 137 ◽  
pp. 93-100 ◽  
Author(s):  
Weiliang Wang ◽  
Hai Zhang ◽  
Junfu Lyu ◽  
Qing Liu ◽  
Guangxi Yue ◽  
...  

2018 ◽  
Vol 131 ◽  
pp. 1-7 ◽  
Author(s):  
Weiliang Wang ◽  
Yuzhao Wang ◽  
Hai Zhang ◽  
Guanming Lin ◽  
Junfu Lu ◽  
...  

Sign in / Sign up

Export Citation Format