Coal Ash Deposition on Nozzle Guide Vanes—Part I: Experimental Characteristics of Four Coal Ash Types

2012 ◽  
Vol 135 (2) ◽  
Author(s):  
J. Webb ◽  
B. Casaday ◽  
B. Barker ◽  
J. P. Bons ◽  
A. D. Gledhill ◽  
...  

An accelerated deposition test facility was operated with four different coal ash species to study the effect of ash composition on deposition rate and spatial distribution. The facility seeds a combusting (natural gas) flow with 10–20 micron mass mean diameter coal ash particulate. The particulate-laden combustor exhaust is accelerated through a rectangular-to-annular transition duct and expands to ambient pressure through a nozzle guide vane annular sector. For the present study, the annular cascade consisted of two CFM56 aero-engine vane doublets, comprising three full passages and two half passages of flow. The inlet Mach number (0.1) and gas temperature (1100 °C) are representative of operating turbines. Ash samples were tested from the three major coal ranks: lignite, subbituminous, and bituminous. Investigations over a range of inlet gas temperatures from 900 °C to 1120 °C showed that deposition increased with temperature, though the threshold for deposition varied with ash type. Deposition levels varied with coal rank, with lignite producing the largest deposits at the lowest temperature. Regions of heightened deposition were noted; the leading edge and pressure surface being particularly implicated. Scanning electron microscopy was used to identify deposit structure. For a limited subset of tests, film cooling was employed at nominal design operating conditions but provided minimal protection in cases of severe deposition.

Author(s):  
J. Webb ◽  
B. Casaday ◽  
B. Barker ◽  
J. P. Bons ◽  
A. D. Gledhill ◽  
...  

An accelerated deposition test facility was operated with three different coal ash species to study the effect of ash composition on deposition rate and spatial distribution. The facility seeds a combusting (natural gas) flow with 10–20 micron mass mean diameter coal ash particulate. The particulate-laden combustor exhaust is accelerated through a rectangular-to-annular transition duct and expands to ambient pressure through a nozzle guide vane annular sector. For the present study, the annular cascade consisted of two CFM56 aero-engine vane doublets; comprising three full passages and two half passages of flow. The inlet Mach number (0.1) and gas temperature (1100°C) are representative of operating turbines. Ash samples were tested from the three major coal ranks: lignite, subbituminous, and bituminous. Investigations over a range of inlet gas temperatures from 900°C to 1120°C showed that deposition increased with temperature, though the threshold for deposition varied with ash type. Deposition levels varied with coal rank, with lignite producing the largest deposits at the lowest temperature. Regions of heightened deposition were noted; the leading edge and pressure surface being particularly implicated. Scanning electron microscopy was used to identify deposit structure. For a limited subset of tests, film cooling was employed at nominal design operating conditions but provided minimal protection in cases of severe deposition.


Author(s):  
C. Smith ◽  
B. Barker ◽  
C. Clum ◽  
J. Bons

This report presents the design and operation of an accelerated testing facility for the study of deposition in turbine nozzle guide vanes (NGV). The facility was designed to produce turbine deposits in a 1–2 hour test that simulates thousands of hours of turbine operation. This is accomplished by matching the net foreign particulate throughput of an actual gas turbine. The facility seeds a combusting (natural gas) flow with 10–20 micron diameter coal ash particulate. The particulate-laden combustor exhaust is accelerated through a rectangular-to-annular transition duct and expands to ambient pressure through an NGV annular sector. The cascade contains two NGV doublets (donated from industry) comprising three full passages and two half passages of flow. The inlet Mach number (0.1) and gas temperature (1000 °C) are representative of operating power turbines. The vanes are film cooled from an auxiliary air supply at nominal design operating conditions. Investigations over a range of inlet gas temperatures showed that deposition increased substantially with temperature, with a threshold for deposition occurring between 900 °C and 1000 °C. Qualitative test validation was achieved using direct comparison with deposits from service hardware. Surface topography analysis indicated that the surface structure of the generated deposits were similar to those found on actual turbine blades. Regions of heightened deposition were noted; the leading edge and pressure surface being particularly implicated. Film cooling is shown to provide substantial protection from deposition.


2015 ◽  
Vol 137 (8) ◽  
Author(s):  
Lamyaa A. El-Gabry ◽  
Ranjan Saha ◽  
Jens Fridh ◽  
Torsten Fransson

An experimental study has been performed in a transonic annular sector cascade of nozzle guide vanes (NGVs) to investigate the aerodynamic performance and the interaction between hub film cooling and mainstream flow. The focus of the study is on the endwalls, specifically the interaction between the hub film cooling and the mainstream. Carbon dioxide (CO2) has been supplied to the coolant holes to serve as tracer gas. Measurements of CO2 concentration downstream of the vane trailing edge (TE) can be used to visualize the mixing of the coolant flow with the mainstream. Flow field measurements are performed in the downstream plane with a five-hole probe to characterize the aerodynamics in the vane. Results are presented for the fully cooled and partially cooled vane (only hub cooling) configurations. Data presented at the downstream plane include concentration contour, axial vorticity, velocity vectors, and yaw and pitch angles. From these investigations, secondary flow structures such as the horseshoe vortex, passage vortex, can be identified and show the cooling flow significantly impacts the secondary flow and downstream flow field. The results suggest that there is a region on the pressure side (PS) of the vane TE where the coolant concentrations are very low suggesting that the cooling air introduced at the platform upstream of the leading edge (LE) does not reach the PS endwall, potentially creating a local hotspot.


Author(s):  
Lamyaa A. El-Gabry ◽  
Ranjan Saha ◽  
Jens Fridh ◽  
Torsten Fransson

An experimental study has been performed in a transonic annular sector cascade of nozzle guide vanes to investigate the aerodynamic performance and the interaction between hub film cooling and mainstream flow. The focus of the study is on the endwalls, specifically the interaction between the hub film cooling and the mainstream. Carbon dioxide (CO2) has been supplied to the coolant holes to serve as tracer gas. Measurements of CO2 concentration downstream of the vane trailing edge can be used to visualize the mixing of the coolant flow with the mainstream. Flow field measurements are performed in the downstream plane with a 5-hole probe to characterize the aerodynamics in the vane. Results are presented for the fully cooled and partially cooled vane (only hub cooling) configurations. Data presented at the downstream plane include concentration contour, axial vorticity, velocity vectors, and yaw and pitch angles. From these investigations, secondary flow structures such as the horseshoe vortex, passage vortex, can be identified and show the cooling flow significantly impacts the secondary flow and downstream flow field. The results suggest that there is a region on the pressure side of the vane trailing edge where the coolant concentrations are very low suggesting that the cooling air introduced at the platform upstream of the leading edge does not reach the pressure side endwall, potentially creating a local hotspot.


Author(s):  
Franz Puetz ◽  
Johannes Kneer ◽  
Achmed Schulz ◽  
Hans-Joerg Bauer

An increased demand for lower emission of stationary gas turbines as well as civil aircraft engines has led to new, low emission combustor designs with less liner cooling and a flattened temperature profile at the outlet. As a consequence, the heat load on the endwall of the first nozzle guide vane is increased. The secondary flow field dominates the endwall heat transfer, which also contributes to aerodynamic losses. A promising approach to reduce these losses is non-axisymmetric endwall contouring. The effects of non-axisymmetric endwall contouring on heat transfer and film cooling are yet to be investigated. Therefore, a new cascade test rig has been set up in order to investigate endwall heat transfer and film cooling on both a flat and a non-axisymmetric contoured endwall. Aerodynamic measurements that have been made prior to the upcoming heat transfer investigation are shown. Periodicity and detailed vane Mach number distributions ranging from 0 to 50% span together with the static pressure distribution on the endwall give detailed information about the aerodynamic behavior and influence of the endwall contouring. The aerodynamic study is backed by an oil paint study, which reveals qualitative information on the effect of the contouring on the endwall flow field. Results show that the contouring has a pronounced effect on vane and endwall pressure distribution and on the endwall flow field. The local increase and decrease of velocity and the reduced blade loading towards the endwall is the expected behavior of the 3d contouring. So are the results of the oil paint visualization, which show a strong change of flow field in the leading edge region as well as that the contouring delays the horse shoe vortex hitting the suction side.


Author(s):  
Mohammad A. Hossain ◽  
Ali Ameri ◽  
James W. Gregory ◽  
Jeffrey P. Bons

Abstract This study includes the design, validation, and fabrication via Direct Metal Laser Sintering (DMLS) of a gas turbine nozzle guide vanes (NGV) that incorporates three innovative cooling schemes specifically enabled by additive manufacturing. The novel NGV design is the culmination of an extensive research and development effort over a period of four years that included low and high speed cascade testing coupled with unsteady CFD for numerous candidate innovative cooling architectures. The final vane design (SJ-vane) consists of sweeping jet (SJ) film cooling holes on the suction surface, sweeping jet impingement holes at the leading edge and double-wall partial length triangular pin-fin with impinging jet at the trailing edge. For comparison purposes, a second DMLS enabled vane (777-vane) was designed and fabricated with prototypical cooling circuits to serve as a baseline. This vane consists of a shaped film cooling holes on the suction surface, circular impingement holes at the leading edge and full length cylindrical pin-fins at the trailing edge. Experiments with the two DMLS enabled vanes were performed at the Ohio State University Turbine Reacting Flow Rig (TuRFR) at engine relevant temperature (1375K) and Mach number conditions. Infrared (IR) thermography was utilized to measure the wall temperature of the pressure and suction surface at several coolant mass flow rates to estimate the overall cooling effectiveness (ϕ). Results showed improved cooling performance for the advanced cooling schemes (sweeping jet film cooling, impingement cooling and triangular pin-fin cooling) compared to the baseline cooling schemes.


Author(s):  
C. Bonilla ◽  
C. Clum ◽  
M. Lawrence ◽  
B. Casaday ◽  
J. P. Bons

An accelerated deposition test facility was used to study the relationship between film cooling, surface temperature, and particle temperature on deposit formation. Tests were run at gas turbine representative inlet Mach numbers (0.1) and temperatures (1090°C). Deposits were created from lignite coal fly ash with mass median diameters of 1.3 and 8.8μm. Two CFM56-5B nozzle guide vane doublets, comprising three full passages and two half passages of flow, were utilized as the test articles. Tests were run with different levels of film cooling back flow margin and coolant temperature. Particle temperature upon impact with the vane surface was shown to be the leading factor in deposition. Since the particle must traverse the boundary layer of the cooled vane before impact, deposition is directly affected by the film and metal surface temperature as well. Film coolant jet strength showed only minor effect on deposit patterns on the leading edge. However, larger Stokes number (resulting in higher particle impact temperature) corresponded with increased deposit coverage area on the showerhead region. Additionally, infrared measurements showed a strong correlation between regions of greater deposits and elevated surface temperature on the pressure surface. Thickness distribution measurements also highlighted the effect of film cooling by showing reduced deposition immediately downstream of cooling holes. Implications for engine operation in particulate-laden environments are discussed.


2021 ◽  
pp. 1-39
Author(s):  
Mohammad A. Hossain ◽  
Ali Ameri ◽  
James W. Gregory ◽  
Jeffrey Bons

Abstract This study includes the design, validation, and fabrication via Direct Metal Laser Sintering (DMLS) of a gas turbine nozzle guide vanes (NGV) that incorporates three innovative cooling schemes specifically enabled by additive manufacturing. The novel NGV design is the culmination of an extensive research and development effort over a period of four years that included low and high speed cascade testing coupled with unsteady CFD for numerous candidate innovative cooling architectures. The final vane design (SJ-vane) consists of sweeping jet (SJ) film cooling holes on the suction surface, sweeping jet impingement holes at the leading edge and double-wall partial length triangular pin-fin with impinging jet at the trailing edge. For comparison purposes, a second DMLS enabled vane (777-vane) was designed and fabricated with prototypical cooling circuits to serve as a baseline. This vane consists of a shaped film cooling holes on the suction surface, circular impingement holes at the leading edge and full length cylindrical pin-fins at the trailing edge. Experiments with the two DMLS enabled vanes were performed at the Ohio State University Turbine Reacting Flow Rig (TuRFR) at engine relevant temperature (1375 K) and Mach number conditions. Infrared (IR) thermography was utilized to measure the wall temperature of the pressure and suction surface at several coolant mass flow rates to estimate the overall cooling effectiveness (ϕ). Results showed improved cooling performance for the advanced cooling schemes (sweeping jet film cooling, impingement cooling and triangular pin-fin cooling) compared to the baseline cooling schemes.


Author(s):  
Mahmood H. Alqefl ◽  
Kedar P. Nawathe ◽  
Pingting Chen ◽  
Rui Zhu ◽  
Yong W. Kim ◽  
...  

Abstract The first stage turbine of a modern gas turbine is subjected to high thermal loads which lead to a need for aggressive cooling schemes to protect its components from melting. Endwalls are particularly challenging to cool due to the complex system of secondary flows near them that wash the protective film coolants into the mainstream. This paper shows that without including combustor cooling, the complex secondary flow physics are not representative of modern engines. Aggressive injection of all cooling flows upstream of the passage is expected to interact and change passage aerodynamics and, subsequently, mixing and transport of coolants. This study describes, experimentally, the aero-thermal interaction of cooling flows near the endwall of a first stage nozzle guide vane passage. The test section involves an engine-representative combustor-turbine interface geometry, combustor coolant flow and endwall film cooling flow injected upstream of a linear cascade. The approach flow conditions represent flow exiting a cooled, low-NOx combustor. This first part of this two-part study aims to understand the complex aerodynamics near the endwall through detailed measurements of passage three-dimensional velocity fields with and without endwall film cooling. The aerodynamic measurements reveal a dominant vortex in the passage, named here as the Impingement Vortex, that opposes the passage vortex formed at the airfoil leading edge plane. This Impingement Vortex completely changes our description of flow over a modern film cooled endwall.


2021 ◽  
pp. 1-54
Author(s):  
Mahmood H. Alqefl ◽  
Kedar P. Nawathe ◽  
Pingting Chen ◽  
Rui Zhu ◽  
Yong W. Kim ◽  
...  

Abstract The first stage turbine of a modern gas turbine is subjected to high thermal loads which lead to a need for aggressive cooling schemes to protect its components from melting. Endwalls are particularly challenging to cool due to the complex system of secondary flows near them that wash the protective film coolants into the mainstream. This paper shows that without including combustor cooling, the complex secondary flow physics are not representative of modern engines. Aggressive injection of all cooling flows upstream of the passage is expected to interact and change passage aerodynamics and, subsequently, mixing and transport of coolants. This study describes, experimentally, the aero-thermal interaction of cooling flows near the endwall of a first stage nozzle guide vane passage. The test section involves an engine-representative combustor-turbine interface geometry, combustor coolant flow and endwall film cooling flow injected upstream of a linear cascade. The approach flow conditions represent flow exiting a cooled, low-NOx combustor. This first part of this two-part study aims to understand the complex aerodynamics near the endwall through detailed measurements of passage three-dimensional velocity fields with and without endwall film cooling. The aerodynamic measurements reveal a dominant vortex in the passage, named here as the Impingement Vortex, that opposes the passage vortex formed at the airfoil leading edge plane. This Impingement Vortex completely changes our description of flow over a modern film cooled endwall.


Sign in / Sign up

Export Citation Format

Share Document