Design of a Thermal Mass Flow Meter for Measurements Within the Rotor Rim Ducts of a Hydroelectric Generator

Author(s):  
Kevin Venne ◽  
Laurent Mydlarski ◽  
Federico Torriano ◽  
Mathieu Kirouac ◽  
Jean-Philippe Charest-Fournier ◽  
...  

To ensure the proper operation of hydroelectric generators, their cooling must be well understood. However, the airflow within such machines is difficult to characterize, and although Computational Fluid Dynamics (CFD) can be a reliable engineering tool, its application to the field of hydroelectric generators is quite recent and has certain limitations which are, in part, due to geometrical and flow complexities, including the coexistence of moving (rotor) and stationary (stator) components. For this reason, experimental measurements are required to validate CFD simulations of such complex flows. Of particular interest is the quantification of the flow within the rotor rim ducts, since it is directly responsible for cooling the poles (one of the most critical components of a hydroelectric generator). Thus, to measure the flow therein, an anemometer was designed. The anemometer had to be accurate, durable, cost-effective, easy to install, and able to withstand the extreme conditions found in hydroelectric generators (temperatures of 45°C, centrifugal forces of 300 g, etc.). In this paper, a thermal mass flow meter and a method for validating its performance, using hot-wire anemometry and a static model of a rotor rim, are described. Preliminary tests demonstrate that the thermal mass flow meter is capable of i) measuring the mass flow rate in the rotor rim ducts with an accuracy of approximately 10%, ii) fitting inside small rectangular ducts (12.2 mm by 51 mm), and iii) resisting forces up to 300 g.

2012 ◽  
Vol 224 ◽  
pp. 435-439
Author(s):  
Jun Hao Jiang ◽  
Shao Zhong Cao

Aiming at the defects of current thermal mass flow sensor, we developed a novel thermal gas mass flowmeter based on the principle of constant power, which consists of semiconductor sensors and a microcontroller as the core controller. The design plan is carried out on the basis of simple structure and reasonable cost, which maximizes accuracy and reliability of the flowmeter. The experimental results verify that the flow meter is running well and achieves the overall performance goals of the plan.


2020 ◽  
Vol 143 (1) ◽  
Author(s):  
Mohammad M. Faghih ◽  
Ahmed Islam ◽  
M. Keith Sharp

Abstract Flow-induced hemolysis remains a concern for blood-contacting devices, and computer-based prediction of hemolysis could facilitate faster and more economical refinement of such devices. While evaluation of convergence of velocity fields obtained by computational fluid dynamics (CFD) simulations has become conventional, convergence of hemolysis calculations is also essential. In this paper, convergence of the power-law hemolysis model is compared for simple flows, including pathlines with exponentially increasing and decreasing stress, in gradually expanding and contracting Couette flows, in a sudden radial expansion and in the Food and Drug Administration (FDA) channel. In the exponential cases, convergence along a pathline required from one to tens of thousands of timesteps, depending on the exponent. Greater timesteps were required for rapidly increasing (large exponent) stress and for rapidly decreasing (small exponent) stress. Example pathlines in the Couette flows could be fit with exponential curves, and convergence behavior followed the trends identified from the exponential cases. More complex flows, such as in the radial expansion and the FDA channel, increase the likelihood of encountering problematic pathlines. For the exponential cases, comparison of converged hemolysis values with analytical solutions demonstrated that the error of the converged solution may exceed 10% for both rapidly decreasing and rapidly increasing stress.


Author(s):  
Kristin Falk ◽  
Rune Killie ◽  
Svein Ha˚heim ◽  
Per Damsleth

Subsea production of oil and gas involves structures on the seabed such as manifolds and X-mas trees that require thermal insulation of piping and valves to avoid gas hydrate formation. The insulation is expensive and time consuming to apply yet may still leave areas with inadequate protection. These “cold spots” accelerate the cooling during a production shutdown. A Heat-Bank concept is developed as an alternative to conventional insulation. The entire subsea structure is covered with an insulated shell. During shutdowns the heated fluid inside the cover keeps the production equipment warm over a prolonged period before hydrates start to form. Computational Fluid Dynamics (CFD) simulations are used to quantify the heat loss effects of natural convection and leakage through openings in the cover. The CFD analyses demonstrate the relative performance of the concept compared to the traditional method of insulating individual piping components. Application of the Heat-Bank concept opens new possibilities for environmentally friendly and cost-effective field development, especially for deep water.


1975 ◽  
Vol 8 (1) ◽  
pp. 3-5 ◽  
Author(s):  
P Lilley ◽  
D H Warne ◽  
B A Mordecai ◽  
A J Spencer