Inlet-Temperature Suppression of Inlet Air for Gas-Turbine Compressors by Evaporative Cooling of Water Spray

Author(s):  
Richard R. Trewin

An evaporative cooling system for lowering the inlet temperature of a gas-turbine compressor is described. This system uses the latent enthalpy of evaporation for injected water droplets to decrease the enthalpy of the air. The requirements for compatible operation between this system and the compressor are given.

Author(s):  
Amir Abbas Zadpoor ◽  
Ali Asadi Nikooyan

The evaporative inlet cooling systems used for inlet cooling of gas turbines during hot summers do not work well in humid areas. However, desiccant wheels can be used to dehumidify the air before passing it trough the evaporative cooler. Since the desiccant wheels work adiabatically, the resulting air is hotter than the air introduced to the wheel and an evaporative cooling system is used to cool down the dehumidified air. Combined direct and indirect evaporative coolers have been already used to investigate the effects of dehumidification on the effectiveness of the evaporation cooling systems. It is shown that a single desiccant wheel does not offer much higher effectiveness compared to the multiple-stage evaporative systems. In this paper, an improved version of the desiccant inlet cooling system is presented. Additional dehumidification and indirect evaporative cooling stages are added to increase the effectiveness of the inlet cooling. A typical gas turbine cycle along with an industrial gas turbine with actual performance curves are used to simulate the thermal cycle in presence of the different inlet cooling systems. The simulations are carried out for three different climatic conditions. The improved and original desiccant-based systems are compared and it is shown that the added stages substantially improve the effectiveness of the desiccant-based inlet cooling.


Processes ◽  
2021 ◽  
Vol 9 (2) ◽  
pp. 332
Author(s):  
Yuanyuan Zhou ◽  
Zhen Yan ◽  
Ming Gao ◽  
Qiumin Dai ◽  
Yanshun Yu

An indirect evaporative cooling system combining with thermoelectric cooling technology (i.e., TIEC system) is proposed, in which a counter-flow plate-fin indirect evaporative cooler is inserted with thermoelectric cooling (i.e., TEC) modules. In hot and humid climate, condensation may occur on the dry channel surface of the cooler. For the TIEC system, with the aid of TEC technology, the surface temperature of the dry channel can be much lower than that of a traditional indirect evaporative cooler, thus, the condensation from the primary air is more likely to take place. A numerical model of this novel TIEC system is developed with specifically taking condensation from primary air into account. Detailed performance analysis of the TIEC system is carried out. Analytical results found that the condensation from primary air reduces the dew point effectiveness by up to 45.0% by weakening the sensible heat transfer but increases the coefficient of performance by up to 62.2% by increasing the latent heat transfer, under given conditions. The effects of main operating conditions, such as the electrical current I and number n of TEC modules, inlet temperature Tp,i, humidity ratio RHp and velocity Vp of the primary air, and the mass flow rate ratio x of secondary to primary air, are investigated under non-condensation and condensation states. It is shown that condensate is more easily produced under higher I, n, Tp,i, RHp, x and lower Vp.


Author(s):  
J. P. Nolan ◽  
V. J. Twombly

This paper discusses the design, installation, operation and performance of a direct mixing evaporative cooling system as an alternate to conventional wetted rigid media systems used for gas turbine power augmentation. The economic return on investment, the ease of installation, and the potential problems as they apply to a typical gas turbine based cogeneration facility are discussed and analyzed. Especially of interest is the low capital cost of this system, approximately one fourth that of a conventional system.


Author(s):  
Hemant Gajjar

Inlet Air Cooling of gas turbine engines for power augmentation has seen increasing application over the past decade. Evaporative inlet air cooling has been particularly preferred by the Gas Turbine operators due to its low cost and ease of installation. Two of the important considerations for a GT operator are the proper selection of the EIAC and, after installation, its proper testing to assure required performance. This paper is based on the experience, as a user, of selecting a inlet air cooling system and then implementing a Fogging type Evaporative Cooling system. It highlights the important parameters related to evaporative cooling system and in particular fogging, and how the site testing can be handled to ensure proper performance. Concepts of ‘Conversion Effectiveness’ and ‘Evaporation Effectiveness’ have also been introduced in this paper.


2017 ◽  
Vol 139 (11) ◽  
Author(s):  
Jose Carmona

Water is a scarce natural resource fundamental for human life. Power plant architects, engineers, and power utilities owners must do everything within their hands and technical capabilities to decrease the usage of water in power plants. This paper illustrates the research carried out by Pöyry Switzerland to reduce the water consumption on power and desalination combined cycle power plants, on which there are gas turbine evaporative cooling systems in operation. The present study analyzed the potential re-utilization and integration of the heat recovery steam generator (HRSG) blowdown into the evaporative cooling system. Relatively clean demineralized water, coming from the HRSG blowdown, is routed to a large water tank, where it is blended with distillate water to achieve the required water quality, before being used on the gas turbine evaporative cooling system. To prove the feasibility of the HRSG blowdown recycling concept, the Ras Al Khair Power and Desalination Plant owned and operated by the Saline Water Conversion Corporation (SWCC), located in the Eastern Province of the Kingdom of Saudi Arabia, was used as case study. Nevertheless, it is important to mention that the principles and methodology presented on this paper are applicable to every power and desalination combined cycle power plant making use of evaporative cooling. Sea water desalination is the primary source for potable water production on Saudi Arabia, with secondary sources being surface water and groundwater extracted from deep wells and aquifers. Saving water is of utmost importance for power plants located in locations where water is scarce, and as such, this paper aims to demonstrate that it is possible to decrease the water consumption of power and desalination combined cycle plants, on which evaporative cooling is used as gas turbine power booster, without having to curtail power production. The outcome of the study indicates that during the summer season, recycling the HRSG water blowdown into the gas turbine evaporative cooling systems would result on the internal water consumption for the gas turbine evaporative coolers decreasing by 545 ton/day, or 23.79%, compared with the original plant design which does not contemplate blowdown re-use. Using evaporative cooling results on an overall gain of 186 MW, or 10.27%, on gross power output, while CO2 emissions decrease by 46.8 ton CO2/h, which represents a 13.8% reduction compared with the case on which the evaporative cooling system is not in operation. A brief cost analysis demonstrated that implementation of the changes would result in a negligible increase of the operational expenses (OPEX) of the plant, i.e., implementation of the suggested modification has an unnoticeable impact on the cost of electricity (CoE). The payback of the project, due to limited operating hours on evaporative cooling every year, is of 12 years for a 30 year plant lifetime, while 2.22 M USD of extra-revenue on potable water sales are generated as a result of implementing the proposed solution. Although in principle this value is modest, the effect of government subsidies on water tariffs as well as political and strategic cost of water is not included on the calculations. In conclusion, the study results indicate that water recycling, and reduction of plant's water footprint for power and desalination combined cycle plants using evaporative cooling, is not only technically possible but commercially feasible.


2008 ◽  
Vol 2008.2 (0) ◽  
pp. 103-104
Author(s):  
Takehiro UEDA ◽  
Nguyen Huy Hoang ◽  
Daisuke MATSUBARA ◽  
Yutaka HASEGAWA ◽  
Ryusuke NUMAKURA ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document