Flow and Heat Transfer Characteristics of a Novel Heat Exchanger

Author(s):  
Haolin Ma ◽  
Alparslan Oztekin

Computational fluid dynamics and heat transfer simulations are conducted for a novel shell-tube type heat exchanger. The heat exchanger consists of tube with a narrow slot oriented in the streamwise direction. Numerical simulations are conducted for the Reynolds number of 1500. The 3D turbulent flow in the tube bank region is modeled by k-ε Reynolds stress averaging method by employing ANSYS FLUENT. 3-D transient flow and heat transfer simulations are conducted to determine the flow structure and temperature profiles in the wake of cylinders in the first row and other rows. The effects of the slot size and the orientation and the arrangement of the cylinder in different configuration will be examined. The slotted tube heat exchanger improved heat transfer by more than 27% compare to the traditional shell-tube heat exchanger without slots. Enhancement in heat transfer is even higher at higher values of Reynolds number.

2014 ◽  
Vol 591 ◽  
pp. 3-6
Author(s):  
M. Raja ◽  
R. Vijayan ◽  
R. Vivekananthan ◽  
M.A. Vadivelu

In the present work, the effect of nanofluid in a shell and tube heat exchanger was studied numerically. The effects of Reynolds number, volume concentration of suspended nanoparticles on the heat transfer characteristics were investigated using CFD software. Finally, the effect of the nanofluid on Shell and tube heat exchanger performance was studied and compared to that of a conventional fluid (i.e., water).


2013 ◽  
Vol 2013 ◽  
pp. 1-5 ◽  
Author(s):  
Amarjit Singh ◽  
Satbir S. Sehgal

In this study, the experimental analysis was performed on the shell-and-tube type heat exchanger containing segmental baffles at different orientations. In the current work, three angular orientations (θ) 0°, 30°, and 60° of the baffles were analyzed for laminar flow having the Reynolds number range 303–1516. It was observed that, with increase of Reynolds number from 303 to 1516, there was a 94.8% increase in Nusselt number and 282.9% increase in pressure drop. Due to increase of Reynolds number from 303 to 1516, there is a decrease in nondimensional temperature factor for cold water (ω) by 57.7% and hot water (ξ) by 57.1%, respectively.


1990 ◽  
Vol 112 (1) ◽  
pp. 64-70 ◽  
Author(s):  
S. A. Idem ◽  
A. M. Jacobi ◽  
V. W. Goldschmidt

The effects upon the performance of an air-to-water copper finned-tube crossflow heat exchanger due to condensation on the outer surface are considered. A four-tube, two-pass heat exchanger was tested over a Reynolds number range (based on hydraulic diameter) from 400 to 1500. The coil was operated both in overall parallel and overall counterflow configurations. Convective heat and mass transfer coefficients are presented as plots of Colburn j-factor versus Reynolds number. Pressure losses are, similarly, presented as plots of the friction factor versus Reynolds number. Enhancement of sensible heat transfer due to the presence of a condensate film is also considered.


Sign in / Sign up

Export Citation Format

Share Document