Digital Image Evaluation Method for Digital Radiography

Author(s):  
Masako Mori ◽  
Toshibumi Kashiwa ◽  
Yoshimitsu Aoki

Digital radiography is becoming one of the common radiographic testing techniques in various industries. However, to apply this new technique to nuclear components, one big issue is how to evaluate the images and ensure that the images have enough quality to be used as inspection record. In film radiography, the IQI, which stands for Image Quality Indicator, have been used to ensure that the films have enough quality to detect any specified defects in the products. In this paper, new alternative IQI that was developed in our previous study for digital radiography to evaluate digital image quality is tested and evaluated. In addition, new image evaluation criteria are also developed and evaluated by calculating MTF, which stands for Modulation Transfer Function, from the IQI images of the products. Finally, the recommended procedures to evaluate radiographic testing image are summarized.

Author(s):  
Masako Mori ◽  
Toshibumi Kashiwa ◽  
Yoshimitsu Aoki

Digital radiography is getting one of the common radiographic testing techniques in various industries now. However, to apply this new technique to nuclear components radiographic testing, one big issue is how we can evaluate and ensure that the taken images have enough image qualities to be used as inspection record. In film radiography, the IQI, which stands for Image Quality Indicator, have been used to ensure that taken films have enough quality to detect any specified defects in the products. So in this paper, new alternative IQI that developed in our previous study for digital radiography to evaluate digital image quality are tested and evaluated. In addition, image evaluation criteria are also developed and evaluated by calculating MTF, which stands for Modulation Transfer Function, from the IQI images taken with the products. Finally, the recommended procedures to evaluate radiographic testing image are summarized.


2016 ◽  
Vol 12 (2) ◽  
pp. 161-168 ◽  
Author(s):  
D. R. Ningtias ◽  
S. Suryono ◽  
S. Susilo

Penelitian yang telah dilakukan adalah pembuatan dan penghitungan kualitas citra digital menggunakan program Modulation Transfer Function (MTF) pada sistem Computed Radiography (CR) untuk kegiatan Quality Control (QC). MTF dapat digunakan untuk menganalisis resolusi spasial citra digital secara akurat. Pada penelitian ini menggunakan phantom yang terbuat dari tembaga berukuran 15x15 cm dengan ketebalan 1 mm. Phantom dieksposi dengan variasi tegangan 50 kV, 60 kV, 70 kV dan 81 kV dan masing-masing dilakukan variasi arus. Data yang diperoleh berupa file citra digital radiografi format DICOM yang kemudian dilakukan analisis kualitas citranya menggunakan PC diluar sistem CR dengan metode MTF. Metode ini sangat efisien dalam melakukan QC resolusi spasial secara kuantitatif sehingga dapat digunakan untuk menilai kualitas pesawat CR. Hasil pengukuran menunjukkan bahwa semakin tinggi tegangan yang digunakan, maka kualitas citra semakin baik dengan arus optimal pada rentang 4-8 mAs dengan rata-rata nilai resolusi spasial 7,26 lp/mm.The research was analyzing of digital image quality by using Modulation Transfer Function (MTF) on Computed Radiography (CR) system for Quality Control (QC). MTF can be used for analyzing digital image spatial resolution accurately. The research used phantom that made of 15x15 cm2 copper and 1 mm thickness. The phantom was expounded with voltage variations by 50 kV, 60 kV, 70 kV dan 81 kV and each of them have been taken by variations of the current. The the image quality of data obtained in the form of radiography digital image files with DICOM format were then analyzed using PC out of CR system with methode of MTF. This methode is really efficient for QC spatial resolution quantitatively and so it can be used for assesing the quality of CR. The measurement results showed that the higher the voltage, the better image quality with optimal current was on the range between 4-8 mAs with the average value of MTF 7,26 lp/mm.


2017 ◽  
Vol 24 (s3) ◽  
pp. 228-234 ◽  
Author(s):  
Fangping Yin

Abstract The result of the extraction of the edge and contour information of the multifunctional digital ship image directly affects the evaluation and recognition of the subsequent image quality. At present, the common method used to extract the edge contour information is based on the Canny operator, and there is a problem that the edge is not clear.In order to obtain more accurate edge information, a method of extracting edge and contour information of multimedia digital image based on multi-scale morphology is proposed. Firstly, the digital ship image is made double filter and the fuzzy threshold segmentation, and then the edge and contour information is extracted by multi-scale morphology. Experiments show that the proposed method can obtain more accurate edge information compared with the other methods.


Author(s):  
Masako Mori ◽  
Toshibumi Kashiwa ◽  
Yoshimitsu Aoki

Radiographic Test (RT) has been widely used in industries to detect inner defects of welded structures or any other significant components. Especially in the nuclear industry, film radiography is the dominant and standardized procedure in performing radiographic testing. Lately emphasis is on digital radiography. One of the most serious concerns for digitization is the lack of image resolution standardizing device like resolution gauge which would determine imaging parameters such as modular transfer function (MTF). This paper proposes line pair type image quality indicator (IQI) corresponding to the current IQIs for both hole and wire type. The advantage of this IQI is to enable easier calibration of testing conditions and quantification of digital RT image quality with required MTF that should be clearly defined in the examination procedures. Furthermore, to acquire “resolution-ensured” digital image of existing RT films, we developed line pair type standardization film. Prototypes of line pair type IQI and line pair type standardization film are currently in the validation study and trial implementing process. These results are also reported in this paper.