Digital deconvolution of scintillation detector signals for high rate photon-counting x-ray imaging applications

Author(s):  
Xiaobing Yue ◽  
Zhi Deng
Author(s):  
M. Lundqvist ◽  
B. Cederstrom ◽  
V. Chmill ◽  
M. Danielsson ◽  
B. Hasegawa

2001 ◽  
Vol 72 (1) ◽  
pp. 717-720 ◽  
Author(s):  
Y. Liang ◽  
K. Ida ◽  
S. Kado ◽  
T. Minami ◽  
S. Okamura ◽  
...  

Sensors ◽  
2016 ◽  
Vol 16 (6) ◽  
pp. 764 ◽  
Author(s):  
Bart Dierickx ◽  
Qiang Yao ◽  
Nick Witvrouwen ◽  
Dirk Uwaerts ◽  
Stijn Vandewiele ◽  
...  

2021 ◽  
Vol 16 (12) ◽  
pp. C12014
Author(s):  
M. Zoladz ◽  
P. Grybos ◽  
R. Szczygiel

Abstract X-ray imaging of moving objects using line detectors remains the most popular method of object content and structure examination with a typical resolution limited to 0.4–1 mm. Higher resolutions are difficult to obtain as, for the detector in the form of a single pixel row, the narrower the detector is, the lower the image Signal to Noise Ratio (SNR). This is because, for smaller pixel sizes, fewer photons hit the pixel in each time unit for a given radiation intensity. To overcome the trade-off between the SNR and spatial resolution, a two-dimensional sensor, namely a pixel matrix can be used. Imaging of moving objects with a pixel matrix requires time-domain integration (TDI). Straightforward TDI implementation is based on the proper accumulation of images acquired during consecutive phases of an object’s movement. Unfortunately, this method is much more demanding regarding data transfer and processing. Data from the whole pixel matrix instead of a single pixel row must be transferred out of the chip and then processed. The alternative approach is on-chip TDI implementation. It takes advantage of photons acquired by multiple rows (a higher SNR), but generates similar data amount as a single pixel row and does not require data processing out of the chip. In this paper, on-chip TDI is described and verified by using a single photon counting two-dimensional (a matrix of 128 × 192 pixels) CdTe hybrid X-ray detector with the 100 µm × 100 µm pixel size with up to four energy thresholds per pixel. Spatial resolution verification is combined with the Material Discrimination X-ray (MDX) imaging method.


2011 ◽  
Vol 59 (5) ◽  
pp. 3114-3119 ◽  
Author(s):  
Yu-Na Choi ◽  
Seung-Wan Lee ◽  
Hyo-Min Cho ◽  
Hyun-Ju Ryu ◽  
Young-Jin Lee ◽  
...  

2020 ◽  
Vol 27 (2) ◽  
pp. 319-328 ◽  
Author(s):  
Leonardo Abbene ◽  
Fabio Principato ◽  
Gaetano Gerardi ◽  
Antonino Buttacavoli ◽  
Donato Cascio ◽  
...  

In this work, the spectroscopic performances of new cadmium–zinc–telluride (CZT) pixel detectors recently developed at IMEM-CNR of Parma (Italy) are presented. Sub-millimetre arrays with pixel pitch less than 500 µm, based on boron oxide encapsulated vertical Bridgman grown CZT crystals, were fabricated. Excellent room-temperature performance characterizes the detectors even at high-bias-voltage operation (9000 V cm−1), with energy resolutions (FWHM) of 4% (0.9 keV), 1.7% (1 keV) and 1.3% (1.6 keV) at 22.1, 59.5 and 122.1 keV, respectively. Charge-sharing investigations were performed with both uncollimated and collimated synchrotron X-ray beams with particular attention to the mitigation of the charge losses at the inter-pixel gap region. High-rate measurements demonstrated the absence of high-flux radiation-induced polarization phenomena up to 2 × 106 photons mm−2 s−1. These activities are in the framework of an international collaboration on the development of energy-resolved photon-counting systems for high-flux energy-resolved X-ray imaging.


2005 ◽  
Vol 32 (6Part21) ◽  
pp. 2157-2158
Author(s):  
PM Shikhaliev ◽  
T Xu ◽  
S Molloi

Sign in / Sign up

Export Citation Format

Share Document