He-Ne laser gain dependence on discharge current and gas pressure from resonant Faraday effect

2000 ◽  
Author(s):  
Alina Gearba ◽  
C. Negutu ◽  
Gabriela Cone ◽  
Ion M. Popescu
2019 ◽  
Vol 90 (11) ◽  
pp. 113312
Author(s):  
Alexey Vizir ◽  
Efim Oks ◽  
Maxim Shandrikov ◽  
Bin Zhang ◽  
Georgy Yushkov

1997 ◽  
Vol 15 (4) ◽  
pp. 589-595 ◽  
Author(s):  
E. Eberl ◽  
T. Wagner ◽  
J. Jacoby ◽  
A. Tauschwitz ◽  
D.H.H. Hoffmann

This paper is reviewing the amplification of XUV radiation at 519.7 and 498.5 Å with a gain-length product of 2.5 and 2.2 for the 4f-3d and 4d-3p transition in an oxygen Z-pinch plasma. Time resolved measurements of the O VI (519.7 Å) transition were performed and the dependence of the line intensity on the discharge current and initial gas pressure is reported.


2014 ◽  
Vol 13 (1) ◽  
Author(s):  
Stefan Karatodorov ◽  
Valentin Mihailov ◽  
Margarita Grozeva

AbstractThe emission characteristics of a scheme combining laser ablation as sample introduction source and hollow cathode discharge as excitation source are presented. The spatial separation of the sample material introduction by laser ablation and hollow cathode excitation is achieved by optimizing the gas pressure and the sample-cathode gap length. At these conditions the discharge current is maximized to enhance the analytical lines intensity.


1989 ◽  
Vol 43 (6) ◽  
pp. 991-997 ◽  
Author(s):  
Jeffrey S. White ◽  
Gae Ho Lee ◽  
Alexander Scheeline

The qualitative dependence of spectrochemical performance of a thetapinch discharge on a variety of experimental variables including discharge gas pressure, sample positioning, discharge energy, and discharge current waveform is reported.


1990 ◽  
Vol 78 (3-4) ◽  
pp. 259-262 ◽  
Author(s):  
P. Mezei ◽  
P. Apai ◽  
M. Jánossy ◽  
K. Rózsa

1981 ◽  
Vol 35 (1) ◽  
pp. 57-59 ◽  
Author(s):  
J. S. Dobrosavljević ◽  
D. S. Pešić

Rotational temperatures in the uncooled hollow cathode discharge (HCD) have been measured. Using rotational lines of the OH (0,0) band, the temperatures were measured in a helium fill gas pressure range from 266 to 2130 Pa and in the discharge current between 0.1 and 0.3 A. A comparative study of these temperatures with gas and excitation temperatures in HCD is presented.


2021 ◽  
Vol 2064 (1) ◽  
pp. 012121
Author(s):  
M V Shandrikov ◽  
A V Vizir ◽  
A S Klimov ◽  
E M Oks ◽  
V P Frolova

Abstract The mass-to-charge ion composition of a planar magnetron discharge plasma has been investigated. The measurements used a modified quadrupole mass-spectrometer and a time-of-flight spectrometer. The experiments were carried out on a copper magnetron target. Argon was used as a working gas. The operating pressure was 0.15÷1.3 Pa. The discharge current was 1÷20 A with a pulse duration of 30÷50 μs. The influence of main operating parameters (discharge current and working gas pressure) on mass-to-charge composition of plasma ions was measured. The mass-to-charge composition of plasma ions in the axial direction was measured as a function of working pressure. Plasma electron temperature was measured and its effect on the mass-to-charge composition of magnetron plasma ions was estimated.


Sign in / Sign up

Export Citation Format

Share Document