Low-cost level and pressure plastic optical fiber sensor

Author(s):  
Matteo Foroni ◽  
Michele Bottacini ◽  
Federica Poli ◽  
Annamaria Cucinotta ◽  
Stefano Selleri
2015 ◽  
Author(s):  
L. Schenato ◽  
G. Bossi ◽  
G. Marcato ◽  
S. Dwivedi ◽  
D. Janse-Van Vuuren ◽  
...  

2021 ◽  
Vol 64 ◽  
pp. 102541
Author(s):  
Pengfei Han ◽  
Linqing Li ◽  
Hao Zhang ◽  
Longzhou Guan ◽  
Carlos Marques ◽  
...  

2010 ◽  
Author(s):  
Víctor M. Muñoz-Berti ◽  
Ana C. López-Pérez ◽  
Benito Alén ◽  
José Luis Costa-Krämer ◽  
Antonio García-Martín ◽  
...  

2013 ◽  
Vol 2013 ◽  
pp. 1-4 ◽  
Author(s):  
Chia-Chin Chiang ◽  
Jian-Cin Chao

An optical fiber solution-concentration sensor based on whispering gallery mode (WGM) is proposed in this paper. The WGM solution-concentration sensors were used to measure salt solutions, in which the concentrations ranged from 1% to 25% and the wavelength drifted from the left to the right. The experimental results showed an average sensitivity of approximately 0.372 nm/% and anR2linearity of 0.8835. The proposed WGM sensors are of low cost, feasible for mass production, and durable for solution-concentration sensing.


2019 ◽  
Vol 1170 ◽  
pp. 012074
Author(s):  
A Arifin ◽  
A K Lebang ◽  
M Yunus ◽  
S Dewang ◽  
I Idris ◽  
...  

2019 ◽  
Vol 2019 ◽  
pp. 1-6
Author(s):  
A. Arifin ◽  
Nelly Agustina ◽  
Syamsir Dewang ◽  
Irfan Idris ◽  
Dahlang Tahir

This research discusses the polymer optical fiber sensor for respiratory measurements. The infrared LED that produces light will propagate along the polymer optical fiber which will be received by the phototransistor and the differential amplifier. The output voltage in the form of an analog signal will be converted to a digital signal by the Arduino Uno microcontroller and displayed on the computer. The polymer optical fiber sensor is installed on the corset using a variety of configuration (straight, sinusoidal, and spiral), placed in the abdomen, and a variety of positions (abdomen, chest, and back) using only a spiral configuration. While doing the inspiration, the stomach will be enlarged so that the optical fiber sensor will have strain. The strain will cause loss of power, the resulting light intensities received by the phototransistor are reduced, and the output voltage on the computer decreases. The result shows that the highest voltage amplitudes were in the spiral configuration placed in the abdominal position for slow respiration measurements with the highest range, sensitivity, and resolution which are 0.119 V, 0.238 V/s, and 0.004 s, respectively. The advantages of our work are emphasized on measurement system simplicity, low cost, easy fabrication, and handy operation and can be connected with the Arduino Uno microcontroller and computer.


1994 ◽  
Author(s):  
Francesco Baldini ◽  
Susanna Bracci ◽  
Franco Cosi

Sign in / Sign up

Export Citation Format

Share Document