A novel x-ray imaging system and its imaging performance

Author(s):  
Chunyu Yu ◽  
Benkang Chang ◽  
Shiyun Wang ◽  
Junju Zhang ◽  
Xiao Yao
2008 ◽  
Vol 22 (11) ◽  
pp. 1045-1050
Author(s):  
H. S. CHO ◽  
S. I. CHOI ◽  
K. Y. KIM ◽  
J. E. OH ◽  
S. Y. LEE ◽  
...  

As a continuation of our digital radiographic sensor R&D, we have developed a digital gamma imaging system based upon the cadmium-telluride ( CdTe ) photoconductor for the applications of industrial gamma imaging. The imaging system consists of a commercially-available CMOS pixel array of a 100 × 100 μ m 2 pixel size and a 5.4 % 151.0 mm 2 active area, coupled with a 750-μm-thick CdTe photoconductor, and a collimated selenium (75 Se ) radioisotope of an about 62.8 Ci activity and a physical size of 3.0 mm in diameter. In this study, we, for the first time, succeeded in obtaining useful gamma images of several test phantoms with the 75 Se radioisotope from the imaging system and evaluated its imaging performance in terms of the modulation transfer function (MTF), the noise power spectrum (NPS), and the detective quantum efficiency (DQE). For comparison, we also tested its X-ray imaging performance with a microfocus X-ray tube of an about 5 μm focal spot size at an operation condition of 90 kVp and 100 μA.


Author(s):  
M. Lundqvist ◽  
B. Cederstrom ◽  
V. Chmill ◽  
M. Danielsson ◽  
B. Hasegawa

Author(s):  
Ho-Il Lee ◽  
Seok-Hwan Bae ◽  
Yeun-Chul Ryu ◽  
Young-Joon Park ◽  
Yong-Gwon Kim

2017 ◽  
Vol 08 (04) ◽  
Author(s):  
Simona Bistazzoni ◽  
Michelangelo De Angelis ◽  
Manuela D ercole ◽  
Carmela Chiaramonte ◽  
Antonio Carotenuto ◽  
...  

1998 ◽  
Vol 5 (3) ◽  
pp. 642-644 ◽  
Author(s):  
J. Y. Huang ◽  
I. S. Ko

A diagnostic beamline is being constructed in the PLS storage ring for measurement of electron- and photon-beam properties. It consists of two 1:1 imaging systems: a visible-light imaging system and a soft X-ray imaging system. In the visible-light imaging system, the transverse beam size and beam position are measured with various detectors: a CCD camera, two photodiode arrays and a photon-beam position monitor. Longitudinal bunch structure is also investigated with a fast photodiode detector and a picosecond streak camera. On the other hand, the soft X-ray imaging system is under construction to measure beam sizes with negligible diffraction-limited error. The X-ray image optics consist of a flat cooled mirror and two spherical focusing mirrors.


2020 ◽  
pp. 1-4
Author(s):  
Sophie Pinel ◽  
Joël Daouk ◽  
Justine Jubréaux ◽  
Alicia Chateau ◽  
Hervé Schohn ◽  
...  

This article highlights the performance measurements of an optical device which aims at upgrading preclinical irradiators. The evaluated device allows acquiring X-ray as well as bioluminescence images with a single sensor. The latter consists of a supercooled camera equipped with a 1024x1024 charge coupling device (each element measuring 13x13µm²). X-ray imaging is feasible, thanks to a conversion phosphor screen. Phantom acquisitions revealed a spatial resolution of 2.5 line pairs per millimetre (0.2mm) for Xray imaging and between 0.4 and 0.7mm for bioluminescence images. Image homogeneity was 0.8 for radiographic images with preclinical imaging parameters and higher than 0.9 for optical images. For functional imaging, contrast to noise ratio (CNR) ranged from 1.3 (for contrast of 2:1 and 0.1s acquisition) up to 253 (for contrast of 32:1 and 5s acquisition). CNR was related to acquisition duration. The device’s overall performance revealed that it is suitable to upgrade existing irradiators and improve laboratory capabilities toward image-guided radiotherapy.


Sign in / Sign up

Export Citation Format

Share Document