Results of the S12 Working Group 11 interlaboratory study to approximate real‐world attenuation of hearing protection devices (HPDs)

1993 ◽  
Vol 94 (3) ◽  
pp. 1791-1791
Author(s):  
Julia D. Royster ◽  
Larry H. Royster
Work ◽  
2018 ◽  
Vol 60 (2) ◽  
pp. 271-279
Author(s):  
Mohsen Aliabadi ◽  
Azam Biabani ◽  
Rostam Golmohammadi ◽  
Maryam Farhadian

Author(s):  
David C. Byrne ◽  
Thais C. Morata

Exposure to industrial noise and the resulting effect of occupational hearing loss is a common problem in nearly all industries. This chapter describes industrial noise exposure, its assessment, and hearing disorders that result from overexposure to noise. Beginning with the properties of sound, noise-induced hearing loss and other effects of noise exposure are discussed. The impact of hearing disorders and the influence of other factors on hearing loss are described. Typically, noise-induced hearing loss develops slowly, and usually goes unnoticed until a significant impairment has occurred. Fortunately, occupational hearing loss is nearly always preventable. Therefore, this chapter gives particular attention to recommendations for measures to prevent occupational hearing loss such as engineering noise controls and hearing protection devices.


2020 ◽  
Vol 92 (12) ◽  
pp. 105-119
Author(s):  
O. Yu. Fomenko ◽  
S. V. Morozov ◽  
S. Mark Scott ◽  
H. Charles Knowles ◽  
D. A. Morozov ◽  
...  

This manuscript summarizes consensus reached by the International Anorectal Physiology Working Group (IAPWG) for the performance, terminology used, and interpretation of anorectal function testing including anorectal manometry (focused on high-resolution manometry), the rectal sensory test, and the balloon expulsion test. Based on these measurements, a classification system for disorders of anorectal function is proposed. Aim to provide information about methods of diagnosis and new classification of functional anorectal disorders to a wide range of specialists general practitioners, therapists, gastroenterologists, coloproctologists all who face the manifestations of these diseases in everyday practice and determine the diagnostic and therapeutic algorithm. Current paper provides agreed statements of IAPWG Consensus and comments (in italics) of Russian experts on real-world practice, mainly on methodology of examination. These comments in no way intended to detract from the provisions agreed by the international group of experts. We hope that these comments will help to improve the quality of examination based on the systematization of local experience with the use of the methods discussed and the results obtained. Key recommendations: the International Anorectal Physiology Working Group protocol for the performance of anorectal function testing recommends a standardized sequence of maneuvers to test rectoanal reflexes, anal tone and contractility, rectoanal coordination, and rectal sensation. Major findings not seen in healthy controls defined by the classification are as follows: rectoanal areflexia, anal hypotension and hypocontractility, rectal hyposensitivity, and hypersensitivity. Minor and inconclusive findings that can be present in health and require additional information prior to diagnosis include anal hypertension and dyssynergia.


Author(s):  
Chanbeom Kwak ◽  
Woojae Han

To prevent intensive noise exposure in advance and be safely controlled during such exposure, hearing protection devices (HPDs) have been widely used by workers. The present study evaluates the effectiveness of these HPDs, partitioned into three different outcomes, such as sound attenuation, sound localization, and speech perception. Seven electronic journal databases were used to search for published articles from 2000 to 2021. Based on inclusion criteria, 20 articles were chosen and then analyzed. For a systematic review and meta-analysis, standardized mean differences (SMDs) and effect size were calculated using a random-effect model. The funnel plot and Egger’s regression analysis were conducted to assess the risk of bias. From the overall results of the included 20 articles, we found that the HPD function performed significantly well for their users (SMDs: 0.457, 95% confidence interval (CI): 0.034–0.881, p < 0.05). Specifically, a subgroup analysis showed a meaningful difference in sound attenuation (SMDs: 1.080, 95% CI: 0.167–1.993, p < 0.05) when to wear and not to wear HPDs, but indicated no significance between the groups for sound localization (SMDs: 0.177, 95% CI: 0.540–0.894, p = 0.628) and speech perception (SMDs: 0.366, 95% CI: −0.100–1.086, p = 0.103). The HPDs work well for their originally designated purposes without interfering to find the location of the sound sources and for talking between the workers. Taking into account various factors, such as the characteristics of the users, selection of appropriate types, and fitting methods for wearing in different circumstances, seems to be necessary for a reliable systematic analysis in terms of offering the most useful information to the workers.


2013 ◽  
Vol 19 (3) ◽  
pp. 127 ◽  
Author(s):  
Noorain Alam ◽  
Vikas Sinha ◽  
Rajiv Jalvi ◽  
Deepanshu Gurnani ◽  
DilavarA Barot ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document