Coherence and the Speech Intelligibility Index

2004 ◽  
Vol 115 (5) ◽  
pp. 2604-2604 ◽  
Author(s):  
James Kates ◽  
Kathryn Arehart
2021 ◽  
Vol 69 (2) ◽  
pp. 173-179
Author(s):  
Nilolina Samardzic ◽  
Brian C.J. Moore

Traditional methods for predicting the intelligibility of speech in the presence of noise inside a vehicle, such as the Articulation Index (AI), the Speech Intelligibility Index (SII), and the Speech Transmission Index (STI), are not accurate, probably because they do not take binaural listening into account; the signals reaching the two ears can differ markedly depending on the positions of the talker and listener. We propose a new method for predicting the intelligibility of speech in a vehicle, based on the ratio of the binaural loudness of the speech to the binaural loudness of the noise, each calculated using the method specified in ISO 532-2 (2017). The method was found to give accurate predictions of the speech reception threshold (SRT) measured under a variety of conditions and for different positions of the talker and listener in a car. The typical error in the predicted SRT was 1.3 dB, which is markedly smaller than estimated using the SII and STI (2.0 dB and 2.1 dB, respectively).


2019 ◽  
Vol 62 (5) ◽  
pp. 1517-1531 ◽  
Author(s):  
Sungmin Lee ◽  
Lisa Lucks Mendel ◽  
Gavin M. Bidelman

Purpose Although the speech intelligibility index (SII) has been widely applied in the field of audiology and other related areas, application of this metric to cochlear implants (CIs) has yet to be investigated. In this study, SIIs for CI users were calculated to investigate whether the SII could be an effective tool for predicting speech perception performance in a population with CI. Method Fifteen pre- and postlingually deafened adults with CI participated. Speech recognition scores were measured using the AzBio sentence lists. CI users also completed questionnaires and performed psychoacoustic (spectral and temporal resolution) and cognitive function (digit span) tests. Obtained SIIs were compared with predicted SIIs using a transfer function curve. Correlation and regression analyses were conducted on perceptual and demographic predictor variables to investigate the association between these factors and speech perception performance. Result Because of the considerably poor hearing and large individual variability in performance, the SII did not predict speech performance for this CI group using the traditional calculation. However, new SII models were developed incorporating predictive factors, which improved the accuracy of SII predictions in listeners with CI. Conclusion Conventional SII models are not appropriate for predicting speech perception scores for CI users. Demographic variables (aided audibility and duration of deafness) and perceptual–cognitive skills (gap detection and auditory digit span outcomes) are needed to improve the use of the SII for listeners with CI. Future studies are needed to improve our CI-corrected SII model by considering additional predictive factors. Supplemental Material https://doi.org/10.23641/asha.8057003


2020 ◽  
Vol 24 ◽  
pp. 233121652097563
Author(s):  
Christopher F. Hauth ◽  
Simon C. Berning ◽  
Birger Kollmeier ◽  
Thomas Brand

The equalization cancellation model is often used to predict the binaural masking level difference. Previously its application to speech in noise has required separate knowledge about the speech and noise signals to maximize the signal-to-noise ratio (SNR). Here, a novel, blind equalization cancellation model is introduced that can use the mixed signals. This approach does not require any assumptions about particular sound source directions. It uses different strategies for positive and negative SNRs, with the switching between the two steered by a blind decision stage utilizing modulation cues. The output of the model is a single-channel signal with enhanced SNR, which we analyzed using the speech intelligibility index to compare speech intelligibility predictions. In a first experiment, the model was tested on experimental data obtained in a scenario with spatially separated target and masker signals. Predicted speech recognition thresholds were in good agreement with measured speech recognition thresholds with a root mean square error less than 1 dB. A second experiment investigated signals at positive SNRs, which was achieved using time compressed and low-pass filtered speech. The results demonstrated that binaural unmasking of speech occurs at positive SNRs and that the modulation-based switching strategy can predict the experimental results.


2019 ◽  
Vol 105 (6) ◽  
pp. 1105-1113
Author(s):  
Clemens Büttner ◽  
Mitsuru Yabushita ◽  
Antonio Sánchez Parejo ◽  
Yu Morishita ◽  
Stefan Weinzierl

The study presents a room acoustical investigation of a representative sample of eight Kabuki theaters as the most important public performance venues of pre-modern Japan. Room acoustical parameters according to ISO 3382 were measured for the unoccupied and simulated for the occupied condition. In comparison with European proscenium stage theaters, they have lower room heights in the auditorium, with usually only one upper tier, and no high stage house for movable scenery. The lower volume per seat results in lower reverberation times, The wooden construction and the audience seating arrangement on wooden straw mats on the floor instead of upholstered seats leads to a mostly flat frequency response up to 4 kHz, resulting in an excellent speech intelligibility, as documented by values for definition (D50) and the speech intelligibility index (STI). The acoustical conditions support the dynamic acting space created by pathways extending the stage from the front through the audience to the rear of the auditorium. They allow great contrasts in the perceived acoustical proximity depending on the selected acting position, and support a high degree of immersion of the audience into the dramatic action.


2020 ◽  
Vol 31 (05) ◽  
pp. 354-362
Author(s):  
Paula Folkeard ◽  
Marlene Bagatto ◽  
Susan Scollie

Abstract Background Hearing aid prescriptive methods are a commonly recommended component of evidence-based preferred practice guidelines and are often implemented in the hearing aid programming software. Previous studies evaluating hearing aid manufacturers' software-derived fittings to prescriptions have shown significant deviations from targets. However, few such studies examined the accuracy of software-derived fittings for the Desired Sensation Level (DSL) v5.0 prescription. Purpose The purpose of this study was to evaluate the accuracy of software-derived fittings to the DSL v5.0 prescription, across a range of hearing aid brands, audiograms, and test levels. Research Design This study is a prospective chart review with simulated cases. Data Collection and Analysis A set of software-derived fittings were created for a six-month-old test case, across audiograms ranging from mild to profound. The aided output from each fitting was verified in the test box at 55-, 65-, 75-, and 90-dB SPL, and compared with DSL v5.0 child targets. The deviations from target across frequencies 250-6000 Hz were calculated, together with the root-mean-square error (RMSE) from target. The aided Speech Intelligibility Index (SII) values generated for the speech passages at 55- and 65-dB SPL were compared with published norms. Study Sample Thirteen behind-the-ear style hearing aids from eight manufacturers were tested. Results The amount of deviation per frequency was dependent on the test level and degree of hearing loss. Most software-derived fittings for mild-to-moderately severe hearing losses fell within ± 5 dB of the target for most frequencies. RMSE results revealed more than 84% of those hearing aid fittings for the mild-to-moderate hearing losses were within 5 dB at all test levels. Fittings for severe to profound hearing losses had the greatest deviation from target and RMSE. Aided SII values for the mild-to-moderate audiograms fell within the normative range for DSL pediatric fittings, although they fell within the lower portion of the distribution. For more severe losses, SII values for some hearing aids fell below the normative range. Conclusions In this study, use of the software-derived manufacturers' fittings based on the DSL v5.0 pediatric targets set most hearing aids within a clinically acceptable range around the prescribed target, particularly for mild-to-moderate hearing losses. However, it is likely that clinician adjustment based on verification of hearing aid output would be required to optimize the fit to target, maximize aided SII, and ensure appropriate audibility across all degrees of hearing loss.


Sign in / Sign up

Export Citation Format

Share Document