typical error
Recently Published Documents


TOTAL DOCUMENTS

84
(FIVE YEARS 25)

H-INDEX

14
(FIVE YEARS 2)

Children ◽  
2022 ◽  
Vol 9 (1) ◽  
pp. 39
Author(s):  
Anke Hua ◽  
Jingyuan Bai ◽  
Yong Fan ◽  
Jian Wang

The study aimed to (1) investigate the reliability and usefulness of a proposed angular analysis during a modified sit-and-reach (MSR) test, and (2) compare the proposed MSR angular analysis and the commonly used MSR distance to verify the influence of the anthropometric characteristics in preschoolers. 194 preschoolers participated in the study. Before testing, the anthropometric characteristics were collected. Each participant performed the MSR test twice. The MSR distance score was obtained from the starting point to the reaching point, while the MSR angle score was calculated according to the approximate hip flexion angle. Both the relative and absolute reliability were good for the angular analysis during an MSR test in preschoolers (ICC ranging from 0.82 to 0.91, CV% ranging from 8.21 to 9.40). The angular analysis demonstrated good usefulness, with a lower typical error than the smallest worthwhile change in 3- and 5-year-old groups. The MSR angle scores could eliminate the concern of the influence of anthropometric characteristics, while MSR distance and anthropometric characteristics (i.e., sitting height and arm length) were found to be weakly correlated. In conclusion, the angular analysis when performing the MSR test is reliable and appears to eliminate the concern regarding the limb length bias.


2021 ◽  
pp. 026010602110573
Author(s):  
J. Iraki ◽  
G. Paulsen ◽  
I. Garthe ◽  
G. Slater ◽  
J.L. Areta

Background: To detect longitudinal changes of resting metabolic rate (RMR) resulting from the effects of energetic stress, reliable RMR measurements are crucial. The Vyntus CPX is a new automated indirect calorimetry system for which RMR reliability has not been determined. Additionally, its agreement with common predictive RMR formulas is unknown. Aim: To determine the within and between-day reliability of RMR measurements using the Vyntus CPX system and its agreement with predictive RMR formulas. Methods: Young (31  ±  7 years) healthy participants (n = 26, 12 females, 14 males) completed three measurements of RMR, two consecutive measures on the same day, one the day before/after, all under standardised conditions. Reliability was assessed with pairwise comparisons of between-day at the same time (BDST), within day consecutive measurements (WDCM) and between-day different time (BDDT), for parameters of reliability (mean change (MC), intraclass correlation (ICC) and typical error of measurement (TEM)). Measured RMR values (kcal/day) were compared against predictive values of 4 common formulas. Results: Parameters of reliability (mean, (95% confidence interval)) were: -BDST: MC, 0.2(-2.3—2.7)% (p = 0.67); ICC, 0.92(0.84—0.97); TEM, 4.5(3.5—6.2)%. -WDCM: MC, −2.5(-6.2—1.3)% (p = 0.21); ICC, 0.88(0.74—0.88); TEM, 7.0(5.4—9.8)%. -BDDT: MC, −1.5(-4.8—1.9)% (p = 0.57); ICC, 0.90(0.76—0.95); TEM, 6.1(4.8—8.5)%. RMRratios (measured/predicted) were: 1.04  ±  0.14 (Nelson, p = 0.13), 1.03  ±  0.10 (Mifflin, p = 0.21), 0.98  ±  0.09 (Harris-benedict, p = 0.30), 0.95  ±  0.11 (Cunningham1980, p = 0.01), 1.00  ±  0.12 (Cunningham1991, p = 0.90) and 0.96  ±  0.13 (DXA, p = 0.03). Conclusions: The Vyntus CPX is reliable and measured RMR values agreed with four predictive formulas but are lower than Cunningham1980 and DXA RMR estimates for this population.


2021 ◽  
Author(s):  
Giuseppe Cocco ◽  
Albert Guillen i Fabregas ◽  
Josep Font-Segura

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Nuno Manuel Frade de Sousa ◽  
Danilo Rodrigues Bertucci ◽  
Gabriel Medeiros de Sant’Ana ◽  
Pedro Luiz Ribeiro Angelucci Padua ◽  
Diogo Mello da Rosa

AbstractThe aim of the study was to evaluate and compare the maximal oxygen uptake ($$\dot{\mathrm{V}}$$ V ˙ O2max) achieved during incremental and decremental protocols in highly trained athletes. Nineteen moderate trained runners and rowers completed, on separate days, (i) an initial incremental $$\dot{\mathrm{V}}$$ V ˙ O2max test (INC) on a treadmill, followed by a verification phase (VER); (ii) a familiarization of a decremental test (DEC); (iii) a tailored DEC; (iv) a test with decremental and incremental phases (DEC-INC); (v) and a repeated incremental test (INCF). During each test $$\dot{\mathrm{V}}$$ V ˙ O2, carbon dioxide production, ventilation, heart and breath rates and ratings of perceived exertion were measured. No differences were observed in $$\dot{\mathrm{V}}$$ V ˙ O2max between INC (61.3 ± 5.2 ml kg−1 min−1) and DEC (61.1 ± 5.1 ml kg−1 min−1; average difference of ~ 11.58 ml min−1; p = 0.831), between INC and DEC-INC (60.9 ± 5.3 ml kg−1 min−1; average difference of ~ 4.8 ml min−1; p = 0.942) or between INC and INCF (60.7 ± 4.4 ml kg−1 min−1; p = 0.394). $$\dot{\mathrm{V}}$$ V ˙ O2max during VER (59.8 ± 5.1 ml kg−1 min−1) was 1.50 ± 2.20 ml kg−1 min−1 lower (~ 2.45%; p = 0.008) compared with values measured during INC. The typical error in the test-to-test changes for evaluating $$\dot{\mathrm{V}}$$ V ˙ O2max over the five tests was 2.4 ml kg−1 min−1 (95% CI 1.4–3.4 ml kg−1 min−1). Decremental tests do not elicit higher $$\dot{\mathrm{V}}$$ V ˙ O2max than incremental tests in trained runners and rowers, suggesting that a plateau in $$\dot{\mathrm{V}}$$ V ˙ O2 during the classic incremental and verification tests represents the maximum ceiling of aerobic power.


2021 ◽  
Vol 6 (2) ◽  
pp. 41
Author(s):  
Senda Sammoud ◽  
Raja Bouguezzi ◽  
Yassine Negra ◽  
Helmi Chaabene

Background: This study aimed to examine the reliability and sensitivity of a change of direction deficit (CoDD) and to establish its relationship with linear sprint speed. Methods: In total, 89 prepubertal male soccer players participated in this study (age = 11.7 ± 1.2 years, maturity offset = −2.4 ± 1.0). Participants performed the 505 CoD speed test and the 20 m linear sprint speed test with a split interval at 5 m and 10 m. The CoDD was calculated as the mean 505 CoD time—the mean 10 to 20 m time interval. To evaluate the reliability of CoDD, the 505 CoD speed test, and 20 m linear sprint speed were performed twice, one week apart. The sensitivity of CoDD was identified by comparing the values of the typical error of measurement (TEM) and smallest worthwhile change (SWC). Results: Results of the reliability analysis indicated an intraclass correlation coefficient (ICC3.1) < 0.50 (0.47) and a TEM expressed as the coefficient of variation > 5% (10.55%). The sensitivity analysis showed that the ability of the CoDD measure to detect small performance changes is “marginal” (TEM (0.12) > SWC0.2 (0.04)). However, good absolute and relative reliability were observed for the 505 CoD speed test (ICC3.1 = 0.75; TEM < 5%). Alike CoDD, the ability of the 505 CoD speed test to detect small performance changes was rated as “marginal” (TEM (0.07 s) > SWC0.2 (0.04 s)). The CoDD revealed a large association with the 505 CoD speed test (r = 0.71). However, non-significant associations were detected between the CoDD and 5 m, 10 m, and 20 m linear sprint speed intervals (r = 0.10 to 0.16, all p > 0.05). Likewise, non-significant correlations between the 505 CoD speed test and 5 m, 10 m, and 20 m linear sprint speed intervals were observed (r = 0.14 to 0.20, all p > 0.05). Conclusions: The CoDD displayed poor reliability and limited ability to detect small changes in performance in prepubertal male soccer players. Due to its limited practical utility, practitioners are advised not to consider CoDD scores during the assessment of prepubertal male soccer players.


2021 ◽  
Vol 69 (2) ◽  
pp. 173-179
Author(s):  
Nilolina Samardzic ◽  
Brian C.J. Moore

Traditional methods for predicting the intelligibility of speech in the presence of noise inside a vehicle, such as the Articulation Index (AI), the Speech Intelligibility Index (SII), and the Speech Transmission Index (STI), are not accurate, probably because they do not take binaural listening into account; the signals reaching the two ears can differ markedly depending on the positions of the talker and listener. We propose a new method for predicting the intelligibility of speech in a vehicle, based on the ratio of the binaural loudness of the speech to the binaural loudness of the noise, each calculated using the method specified in ISO 532-2 (2017). The method was found to give accurate predictions of the speech reception threshold (SRT) measured under a variety of conditions and for different positions of the talker and listener in a car. The typical error in the predicted SRT was 1.3 dB, which is markedly smaller than estimated using the SII and STI (2.0 dB and 2.1 dB, respectively).


2021 ◽  
Vol 502 (4) ◽  
pp. 5200-5209
Author(s):  
K Woodcock ◽  
G A Wade ◽  
O Kochukhov ◽  
J Sikora ◽  
A Pigulski

ABSTRACT τ9 Eri is a Bp star that was previously reported to be a single-lined spectroscopic binary. Using 17 ESPaDOnS spectropolarimetric (Stokes V) observations, we identified the weak spectral lines of the secondary component and detected a strong magnetic field in the primary. We performed orbital analysis of the radial velocities of both components to find a slightly eccentric orbit (e = 0.129) with a period of 5.95382(2) d. The longitudinal magnetic field (Bℓ) of the primary was measured from each of the Stokes V profiles, with typical error bars smaller than 10 G. Equivalent widths (EWs) of least-squares deconvolution profiles corresponding to only the Fe lines were also measured. We performed frequency analysis of both the Bℓ and EW measurements, as well as of the Hipparcos, SMEI, and TESS photometric data. All sets of photometric observations produce two clear, strong candidates for the rotation period of the Bp star: 1.21 and 3.82 d. The Bℓ and EW measurements are consistent with only the 3.82-d period. We conclude that HD 25267 consists of a late-type Bp star (M = $3.6_{-0.2}^{+0.1}~\mathrm{ M}_\odot$, T = $12580_{-120}^{+150}$ K) with a rotation period of 3.82262(4) d orbiting with a period of 5.95382(2) d with a late-A/early-F type secondary companion (M = 1.6 ± 0.1 M⊙, T = $7530_{-510}^{+580}$ K). The Bp star’s magnetic field is approximately dipolar with i = 41 ± 2°, β = 158 ± 5°, and Bd = 1040 ± 50 G. All evidence points to the strong 1.209912(3)-d period detected in photometry, along with several other weaker photometric signals, as arising from g-mode pulsations in the primary.


Kinesiology ◽  
2021 ◽  
Vol 53 (2) ◽  
pp. 215-225
Author(s):  
Ricardo Berton ◽  
Marcos Soriano ◽  
Demostenys David da Silva ◽  
Marcel Lopes dos Santos ◽  
Gustavo Teixeira ◽  
...  

The study investigated the concurrent validity and reliability of the load-velocity relationship to predict the one-repetition maximum (1RM) of the power clean from the knee (PCK), high pull from the knee (HPK), and mid-thigh clean pull (MTCP). For each exercise, 12 participants performed two 1RM sessions tests and two sessions to measure the barbell’s load-velocity relationship at 30, 45, 60, 75, and 90% of 1RM. The velocity recorded at each load was used to establish the linear regression equation and, consequently, to predict 1RM value. A low validity between the 1RM direct test and predicted 1RM was observed for PCK (typical error [TE]=3.96 to 4.50 kg, coefficient of variation [CV]=4.68 to 5.27%, effect size [ES]=-0.76 to -0.58, Bland-Altman bias [BAB]=9.83 to 11.19 kg), HPK (TE=4.58 to 5.82 kg, CV=6.44 to 8.14%, ES=-0.40 to -0.39, BAB=3.52 to 4.17 kg), and MTCP (TE=6.33 to 8.08 kg, CV=4.78 to 6.16%, ES=-0.29 to -0.19, BAB=3.98 to 6.17 kg). Adequate reliability was observed for the 1RM direct test and for the predicted 1RM. However, based on Bland-Altman limits of agreement, lower measurement errors were obtained for the 1RM direct test in comparison to the predicted 1RM for all the exercises. In conclusion, the load-velocity relationship was not able to predict 1RM values with high accuracy in the PCK, HPK, and MTCP. Moreover, the 1RM direct test was the most reliable for PCK, HPK and MTCP.


2021 ◽  
pp. 1-5
Author(s):  
Gabriel dos Santos Oliveira ◽  
João Breno de Araujo Ribeiro-Alvares ◽  
Felipe Xavier de Lima-e-Silva ◽  
Rodrigo Rodrigues ◽  
Marco Aurélio Vaz ◽  
...  

Context: Eccentric knee flexor strength assessments have a key role in both prevention and rehabilitation of hamstring strain injuries. Objective: To verify the reliability of a clinical test for measuring eccentric knee flexor strength during the Nordic hamstring exercise using a commercially available handheld dynamometer. Design: Reliability study. Setting: Physical Therapy Laboratory, Federal University of Health Sciences of Porto Alegre (Brazil). Participants: Fifty male amateur athletes (soccer or rugby players; 24 [3] y). Main Outcome Measures: Eccentric knee flexor strength. Results: When compared with a load cell–based device, the clinical test using a handheld dynamometer provided smaller force values (P < .05) with large effect sizes (.92–1.21), moderate intraclass correlation (.60–.62), typical error of 30 to 31 N, and coefficient of variation of 10% to 11%. Regarding the test–retest reproducibility (2 sessions separated by 1 week), the clinical test provided similar force values (P > .05) with only small effect sizes (.20–.27), moderate to good correlation (.67–.76), typical error of 23 to 24 N, and coefficient of variation of 9% to 10%. Conclusion: The clinical test with handheld dynamometer proposed by this study can be considered an affordable and relatively reliable tool for eccentric knee flexor strength assessment in the clinical setting, but results should not be directly compared with those provided by load cell–based devices.


Sign in / Sign up

Export Citation Format

Share Document