scholarly journals Wind turbine sound pressure level calculations at dwellings

2016 ◽  
Vol 139 (3) ◽  
pp. 1436-1442 ◽  
Author(s):  
Stephen E. Keith ◽  
Katya Feder ◽  
Sonia A. Voicescu ◽  
Victor Soukhovtsev ◽  
Allison Denning ◽  
...  
2018 ◽  
Vol 144 (2) ◽  
pp. 981-996 ◽  
Author(s):  
Stephen E. Keith ◽  
Gilles A. Daigle ◽  
Michael R. Stinson

2021 ◽  
Vol 263 (2) ◽  
pp. 4048-4057
Author(s):  
Christoph Pörschmann ◽  
Stephan Großarth ◽  
Johannes M. Arend ◽  
Sebastian Schmitter ◽  
Dirk Schreckenberg ◽  
...  

Current literature suggests that annoyance of wind turbine noise is strongly affected by amplitude modulations (AM). A survey was carried out at five German residential study sites near wind turbines with a total of about 500 residents to study the effects of AM in more detail. Annoyance, disturbances, and the perception of wind turbine noise characteristics, including AM, were assessed. For each participant, address-related exposure to rating levels of wind turbines was estimated. Further, we carried out headphone-based listening experiments with participants from three of the five study areas and with non-exposed participants from another 'control' location. In the listening experiments, perceived annoyance was rated for varying AM and for different A-weighted sound pressure levels for a total number of 79 subjects. As expected, the results show an increase in annoyance with sound pressure level. Furthermore, annoyance increased significantly with the extent of amplitude modulations. Interestingly, annoyance showed a strong rise as soon as amplitude modulations became audible in the signal and this rise was hardly affected by the sound pressure level. In our contribution, we present comparisons of the results of the survey and the listening experiments.


2019 ◽  
Vol 2019 ◽  
pp. 1-11
Author(s):  
Jianlong Ma ◽  
Yafan Duan ◽  
Ming Zhao ◽  
Wenchun Lv ◽  
Jianwen Wang ◽  
...  

Although the optimization of wind turbine blade aerodynamic performance has achieved fruitful results, whether airfoil concavity, an important method for preventing flow separation, is also feasible for improving the aerodynamic performance has not been confirmed scientifically. Thus, we selected the blade of a small horizontal-axis wind turbine as a research model and proposed an optimization method based on airfoil concavity near the trailing edge of the blade suction surface. The experimental results showed that airfoil concavity improved blade aerodynamic performance by 3–15%. Subsequently, its effects on the sound pressure level within the wake flow field were investigated using an acoustic array, and the results suggested that the sound pressure level was reduced by 9.6–15.8%. Lastly, a modal test of the rotor blade was conducted. Although the natural frequencies of the 1st and 2nd order vibrations had hardly changed, their vibrational stiffness were increased by 7 and 4.9%, respectively, which indicated that airfoil concavity significantly improved structural robustness.


2021 ◽  
Vol 347 ◽  
pp. 00013
Author(s):  
Errol Molatudi ◽  
Thokozani Justin Kunene ◽  
Lagouge Kwanda Tartibu

The effects of sound pressure level at two observation positions of a fixed and varied blade pitch angle at Low-Mach unsteady incompressible Reynolds-Average Navier-Stokes flow approach, on an H-rotor Vertical Axis Wind Turbine. The objective of the study is to compare the noise dissipation and output power/energy of the airfoil blades design of the vertical axis wind turbine in residential zones. The Ffowcs Williams-Hawkings (FHWH) techniques were applied to validate the output noise and vortex shedding of the different angles of attacks (AoA). The study postulated that the time history of the calculated sound pressure level at two observers positions: the aeroacoustic, blade vortex interaction noise, flow separations, dynamic stall experience from varied angled of attacks are found to produces less noise and vortex shedding compared to the fixed angle of attack.


Acta Acustica ◽  
2020 ◽  
Vol 4 (3) ◽  
pp. 10
Author(s):  
Guillaume Dutilleux ◽  
Jean Fosset

While most of the countries over the world rely on sound-pressure-level-based limit values to regulate wind energy development, sound emergence as defined in ISO 1996-1 is used in a few national legislations but also in international guidelines. There is however no published evidence that sound emergence is a relevant noise descriptor for that kind of source, namely that there is a correlation between this metric and perception or annoyance. A listening test was carried out to evaluate the relative merits of sound pressure level and sound emergence as predictors of annoyance from wind turbine noise. The test samples consisted of 45 30-s wind turbine sounds at three different A-weighted sound pressure levels and five different signal-to-noise ratios. Thirty two persons rated the test samples according to the ISO 15666 standard scale in a dry room equipped with loudspeakers. The results indicate that short term annoyance is better predicted by A-weighted sound pressure levels than by sound emergence. It is also observed that sound emergence is a poor predictor of the audibility of wind turbine sounds.


2020 ◽  
Vol 63 (4) ◽  
pp. 931-947
Author(s):  
Teresa L. D. Hardy ◽  
Carol A. Boliek ◽  
Daniel Aalto ◽  
Justin Lewicke ◽  
Kristopher Wells ◽  
...  

Purpose The purpose of this study was twofold: (a) to identify a set of communication-based predictors (including both acoustic and gestural variables) of masculinity–femininity ratings and (b) to explore differences in ratings between audio and audiovisual presentation modes for transgender and cisgender communicators. Method The voices and gestures of a group of cisgender men and women ( n = 10 of each) and transgender women ( n = 20) communicators were recorded while they recounted the story of a cartoon using acoustic and motion capture recording systems. A total of 17 acoustic and gestural variables were measured from these recordings. A group of observers ( n = 20) rated each communicator's masculinity–femininity based on 30- to 45-s samples of the cartoon description presented in three modes: audio, visual, and audio visual. Visual and audiovisual stimuli contained point light displays standardized for size. Ratings were made using a direct magnitude estimation scale without modulus. Communication-based predictors of masculinity–femininity ratings were identified using multiple regression, and analysis of variance was used to determine the effect of presentation mode on perceptual ratings. Results Fundamental frequency, average vowel formant, and sound pressure level were identified as significant predictors of masculinity–femininity ratings for these communicators. Communicators were rated significantly more feminine in the audio than the audiovisual mode and unreliably in the visual-only mode. Conclusions Both study purposes were met. Results support continued emphasis on fundamental frequency and vocal tract resonance in voice and communication modification training with transgender individuals and provide evidence for the potential benefit of modifying sound pressure level, especially when a masculine presentation is desired.


2020 ◽  
Vol 68 (2) ◽  
pp. 137-145
Author(s):  
Yang Zhouo ◽  
Ming Gao ◽  
Suoying He ◽  
Yuetao Shi ◽  
Fengzhong Sun

Based on the basic theory of water droplets impact noise, the generation mechanism and calculation model of the water-splashing noise for natural draft wet cooling towers were established in this study, and then by means of the custom software, the water-splashing noise was studied under different water droplet diameters and water-spraying densities as well as partition water distribution patterns conditions. Comparedwith the water-splashing noise of the field test, the average difference of the theoretical and the measured value is 0.82 dB, which validates the accuracy of the established theoretical model. The results based on theoretical model showed that, when the water droplet diameters are smaller in cooling tower, the attenuation of total sound pressure level of the water-splashing noise is greater. From 0 m to 8 m away from the cooling tower, the sound pressure level of the watersplashing noise of 3 mm and 6 mm water droplets decreases by 8.20 dB and 4.36 dB, respectively. Additionally, when the water-spraying density becomes twice of the designed value, the sound pressure level of water-splashing noise all increases by 3.01 dB for the cooling towers of 300 MW, 600 MW and 1000 MW units. Finally, under the partition water distribution patterns, the change of the sound pressure level is small. For the R s/2 and Rs/3 partition radius (Rs is the radius of water-spraying area), when the water-spraying density ratio between the outer and inner zone increases from 1 to 3, the sound pressure level of water-splashing noise increases by 0.7 dB and 0.3 dB, respectively.


Sign in / Sign up

Export Citation Format

Share Document